Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"MVCT"”.

  1. Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification

    … work, the detector array output sinogram of an MVCT imaging study is used to produce images of an object at different locations along a pattern of motion and the multi-leaf collimator (MLC) control sinogram is used to translate dose distributions in space. A temporal re-binning algorithm was …

    ut-knoxville Repository record for Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification (opens in a new tab)

  2. Bildgeführte dosiseskalierte Strahlentherapie des Prostatakarzinoms mittels helikaler Tomotherapie

    … IGRT basierend auf Megavoltcomputertomographien (MVCT) bzw. implantierten Markern. 2) Barelkowski et al. analysierten die klinischen Ergebnisse einer Kohorte, welche mit primärer MVCT-basierter IGRT behandelt wurde. Die verschriebene Dosis in der Prostata betrug bei niedrigem und günstigem …

    fu-berlin Repository record for Bildgeführte dosiseskalierte Strahlentherapie des Prostatakarzinoms mittels helikaler Tomotherapie (opens in a new tab)

  3. ORGAN MOTION AND IMAGE GUIDANCE IN RADIATION THERAPY

    … pre-treatment mega voltage computed tomography (MVCT) provided the real-time tumor and organ shift coordinates, and can be used to improve the accuracy of patient positioning. The interfractional system errors and random errors were analyzed and the suggested margins for HN, brain, prostate, …

    vcu Repository record for ORGAN MOTION AND IMAGE GUIDANCE IN RADIATION THERAPY (opens in a new tab)

  4. Assessment of a Treatment Planning Protocol for the Reduction of Dosimetry Calculation Errors in Radiotherapy for Head and Neck Patients with Dental Implants

    … to assess the appearance of artifacts. An MVCT image set was merged with the corresponding kVCT image to improve visualization of the dental implants for use in density overrides. Three ion chamber measurement points in the simulated mouth facilitated the determination of measured dose …

    mcmaster Repository record for Assessment of a Treatment Planning Protocol for the Reduction of Dosimetry Calculation Errors in Radiotherapy for Head and Neck Patients with Dental Implants (opens in a new tab)

  5. Assessment on the Precision of Total Marrow Irradiation: From Clinical to Preclinical Implementation

    … which was minimized in mice treated with TMI. MVCT imaging and whole-body patient immobilization was essential for assessing treatment setup, allowing for the complete analysis of 3D dose distribution in the PTV and lungs. The development of a new 3D targeted preclinical system paves the way …

    umn Repository record for Assessment on the Precision of Total Marrow Irradiation: From Clinical to Preclinical Implementation (opens in a new tab)

  6. Characterisation and Modification of the Optical Properties of Zirconia-Based Ceramics for Aesthetic Dental Restorations

    … (IVCT), and multivalence charge transfer (MVCT). Fourth, electron paramagnetic resonance (EPR) spectroscopy was used to confirm the feasibility of formation of different defect types. The experimental outcomes of the experimental work were extensive, involving presentation and analysis of …

    unsw Repository record for Characterisation and Modification of the Optical Properties of Zirconia-Based Ceramics for Aesthetic Dental Restorations (opens in a new tab)

  7. Inter-/ intrafraktionelle Variationen und dosimetrische Auswirkungen bei der Bestrahlung von Prostatakarzinomen

    … wurde eine Megavoltage- Computertomographie (MVCT) angewandt. Zur Auswertung der einzelnen Bestrahlungen wurde das Softwaremodul Planned Adaptive des Tomotherapiesystems genutzt. Der Einsatz von Goldmarkern erhöhte die Genauigkeit der Bestrahlung entlang der y-Achse um 4,5mm gegenüber der …

    fu-berlin Repository record for Inter-/ intrafraktionelle Variationen und dosimetrische Auswirkungen bei der Bestrahlung von Prostatakarzinomen (opens in a new tab)

  8. Evaluation of Tumor Localization in Respiration Motion-Corrected Stereotactic Body Radiotherapy Patients Treated with TomoTherapy.

    … per minute (bpm). TomoTherapy megavoltage CT (MVCT) scans did not show marked interplay effect. Scanning in fine mode resulted in smaller positional errors, though larger imaging artifacts were visible. Lower breath frequencies were significantly associated with larger variance in dose, and …

    hawaii Repository record for Evaluation of Tumor Localization in Respiration Motion-Corrected Stereotactic Body Radiotherapy Patients Treated with TomoTherapy. (opens in a new tab)

  9. CT Image Electron Density Quantification in Regions with Metal Implants: Implications for Radiotherapy Treatment Planning

    In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is …

    queens Repository record for CT Image Electron Density Quantification in Regions with Metal Implants: Implications for Radiotherapy Treatment Planning (opens in a new tab)