  1. Large spacecraft medium voltage DC (MVDC) power and propulsion system

    … introduces a medium voltage direct-current (MVDC) system for large spacecrafts with megawatt (MW)-scale power and propulsion systems for interplanetary transport. The proposed MVDC system comprises a nuclear electric propulsion (NEP) powered permanent magnet generator, a solar photovoltaic …

    ndsu Repository record for Large spacecraft medium voltage DC (MVDC) power and propulsion system (opens in a new tab)

  2. Fault Analysis in MMC-based Multi-terminal HVDC and MVDC Systems

    … and the structures of multiterminal HVDC and MVDC networks.

    unsw Repository record for Fault Analysis in MMC-based Multi-terminal HVDC and MVDC Systems (opens in a new tab)

  3. Medium voltage direct current (MVDC) converter for pebble bed modular reactor (PBMR)

    … the reason why a Medium Voltage Direct Current (MVDC) converter was chosen over a High Voltage Direct Current (HVDC)for the PBMR system. MVDC converters can be used to start-up the PBMR without the Start-up Blower System and Static Frequency converter. The converter can also control the active …

    nwu-za Repository record for Medium voltage direct current (MVDC) converter for pebble bed modular reactor (PBMR) (opens in a new tab)

  4. Shipboard MVDC Voltage Stabilization by Negative Load Energy Storage Compensated Virtual Capacitance

    Shipboard MVDC power systems need to support pulsed loads, which have destabilizing ef-fects on the MVDC power transmission bus voltage. Despite the reference shipboard MVDC architecture having energy storage to buffer the large power swings of pulsed loads, a large constant power still needs to be …

    vt Repository record for Shipboard MVDC Voltage Stabilization by Negative Load Energy Storage Compensated Virtual Capacitance (opens in a new tab)

  5. Fault-Tolerant High-Density Power Converters and In-Situ Health Prediction for Offshore MVDC Distribution

    … density and robustness in medium-voltage DC (MVDC) electric distribution systems is proposed in this dissertation. A SiC-MOSFET-based 6 MW, 36/6 kV ISOSP (input series output series-parallel) modular stacked DC/DC SST is proposed using medium frequency (MF) transformer isolation. This …

    houston Repository record for Fault-Tolerant High-Density Power Converters and In-Situ Health Prediction for Offshore MVDC Distribution (opens in a new tab)

  6. Hybrid Modular Multilevel Converter Family and Modular DC Circuit Breaker for Medium-voltage DC (MVDC) Applications

    … efficiency, and flexibility. Medium-voltage DC (MVDC) applications, including shipboard, railway systems, distribution networks, and microgrids, are emerging as critical areas of interest. To integrate MVDC systems with existing power grids, MV AC/DC conversion techniques are crucial. Moreover, …

    vt Repository record for Hybrid Modular Multilevel Converter Family and Modular DC Circuit Breaker for Medium-voltage DC (MVDC) Applications (opens in a new tab)

  7. An adaptive, multi-rate linear quadratic regulator for a shipboard MVDC distribution system with constant power loads

    Future U.S. Navy warships will have DC electrical distribution systems. These distribution systems will include multiple layers of electronic power converters. When coupled to high-bandwidth controllers, power converters behave as constant power loads to the distribution system. Constant power …

    nps Repository record for An adaptive, multi-rate linear quadratic regulator for a shipboard MVDC distribution system with constant power loads (opens in a new tab)

  8. Modeling, Control, and Fault-tolerant Operation of the Isolated Modular Multilevel DC-DC Converter for MVDC Applications

    The global transition to green energy generation is accelerating, marked by the increasing integration of renewable energy sources into power grids. Simultaneously, as the electrification of energy demands progresses, there is also growth in energy storage systems and the adoption of novel DC …

    gatech Repository record for Modeling, Control, and Fault-tolerant Operation of the Isolated Modular Multilevel DC-DC Converter for MVDC Applications (opens in a new tab)

  9. Active gate drive based hybrid MVDC circuit breaker with a modular architecture for flexible voltage and current ratings

    MVDC networks present an effective means for integrating renewable-based Distributed Generators into the power network. Protection of Medium Voltage Direct Current (MVDC) networks presents significant challenges, including the absence of natural zero crossings, rapid fault current rise, and a lack …

    manitoba Repository record for Active gate drive based hybrid MVDC circuit breaker with a modular architecture for flexible voltage and current ratings (opens in a new tab)

  10. Modelling, System-Level Control, Fault Protection, and Power Flow Analysis in Medium-Voltage DC Systems

    Medium-voltage DC (MVDC) systems, typically operating between ±0.75 kV and ±50 kV, are emerging as a promising solution for modern power networks. Their potential applications span sub-transmission, distribution, and collection networks, providing enhanced support for the integration of regional …

    unsw Repository record for Modelling, System-Level Control, Fault Protection, and Power Flow Analysis in Medium-Voltage DC Systems (opens in a new tab)

  11. Modular multilevel converter with full-bridge submodules for flexible medium voltage DC electric railway systems

    … in the literature. The Medium-voltage DC (MVDC) railway electrification systems are suitable options for the mainline and high-speed electric railways and have a wide range of advantages over the traditional AC and DC electrification systems. The benefits include but are not limited to less …

    birmingham Download PDF for Modular multilevel converter with full-bridge submodules for flexible medium voltage DC electric railway systems (opens in a new tab)

  12. Reliability Evaluation of Modular Multilevel Converters for Medium Voltage Direct Current Applications

    Medium-voltage dc (MVDC) systems are attracting significant attention due to the rapid growth of dc loads, such as e-mobility, railways, and data centers where such systems can be attractive alternatives. Additionally, the integration of wind farms, photovoltaic (PV) energy, and battery energy …

    unsw Repository record for Reliability Evaluation of Modular Multilevel Converters for Medium Voltage Direct Current Applications (opens in a new tab)

  13. MODELING AND CONTROL OF A MODULAR MULTILEVEL RECTIFIER

    Medium-voltage direct current (MVDC) systems will be the backbone of power systems in the future naval fleet due to its numerous benefits compared with the existing medium-voltage alternating current (MVAC) systems. The rectifier is a key component in an MVDC system that converts the AC electrical …

    nps Repository record for MODELING AND CONTROL OF A MODULAR MULTILEVEL RECTIFIER (opens in a new tab)

  14. Power Electronic Solutions for Interfacing Offshore Wind Turbine Generators to Medium Voltage DC Collection Grids

    … to use a medium voltage direct current (MVDC) collection grid when siting farms >150 km from shore. To date, no offshore wind farm features an MVDC collection grid. However, MVDC collection grids are expected to be deployed with future offshore wind farms as they are sited further out to …

    tamu Repository record for Power Electronic Solutions for Interfacing Offshore Wind Turbine Generators to Medium Voltage DC Collection Grids (opens in a new tab)

  15. A novel backup protection scheme for hybrid AC/DC power systems

    … DC faults that are not cleared by the main MVDC (Medium Voltage DC) link protection. The protection scheme relies on the apparent impedance measured at the AC "side" of the MVDC link to detect faults on the DC system. It can be readily implemented on existing distance protection relays with …

    strathclyde Repository record for A novel backup protection scheme for hybrid AC/DC power systems (opens in a new tab)

  16. Z-source Circuit Breakers in Naval Power Systems

    … are needed to facilitate the US Navy's move to MVDC systems on future vessels. Integrating the z-source circuit breaker into a "typical" naval MVDC power system requires understanding system dynamics that may cause the breaker to inadvertently energize a circuit through regenerative turn-on of …

    nps Repository record for Z-source Circuit Breakers in Naval Power Systems (opens in a new tab)

  17. Modeling, Design, and Control of Heterogeneous Inverter-Based Power Distribution Networks with High DER Penetration

    … power distribution network, a medium voltage DC (MVDC) distribution network, is investigated in the study. First, the dissertation proposes an effective fault management scheme for MVDC networks, which includes a virtual-impedance-based fault current limiter (VI-FCL) on the DC side and a …

    temple Repository record for Modeling, Design, and Control of Heterogeneous Inverter-Based Power Distribution Networks with High DER Penetration (opens in a new tab)

  18. Efficient Generation of Power In Medium Voltage Direct Current Systems: Variable Speed Operation and Rectifier Considerations

    … efficient Medium Voltage Direct Current (MVDC) power systems. The research reported here offered solutions to the following issues: 1) Efficiency improvement of a gas turbine by running it in variable speed operation mode. 2) The advantages and disadvantages of different ac-dc rectifier …