  1. The Mach-Zehnder coupler

    … and fiber optical delay lines to construct Mach-Zehnder couplers which comprise the main building block of the CSK receiver. There were two main goals of this thesis research. The first was to investigate design and construction modifications which would lower the system loss of a previously …

    nps Repository record for The Mach-Zehnder coupler (opens in a new tab)

  2. The Mach-Zehnder coupler.

    … of an optical signal demultiplexer based on the Mach-Zehnder coupler. The theory behind the signal demultiplexer involves cascading an n stage Mach-Zehnder coupler. The coupler will be capable of discriminating between M different CSK signals employing M Hadamard code. This thesis involves the …

    nps Repository record for The Mach-Zehnder coupler. (opens in a new tab)

  3. Temporal mach bands: a psychophysical study

    … of temporal contours analogous to the Mach band effects in spatial vision. A transient overshoot in the incremental threshold occurred immediately after the crest of rising linear ramps at photopic levels. A psychophysical matching experiment verified that this peaking effect is …

    auckland-ms Repository record for Temporal mach bands: a psychophysical study (opens in a new tab)

  4. Mach and froude numbers on Mars.

    … winter, which motivates this study of the Mach number, Ma (the ratio offlow speed to the speed of sound), and the Froude number, Fr (the ratio of flowspeed to the speed of buoyancy waves), as a function of season and location. Twoglobal reanalyses spanning Mars Years (MY) 24 to 33 are used …

    louisville Repository record for Mach and froude numbers on Mars. (opens in a new tab)

  5. Electrooptic mach-zehnder modulators in gallium arsenide

    … based on the integrated optics version of the Mach-Zehnder interferometer, using GaAs substrates, were modelled and fabricated for use with these slow-wave electrodes. The variational method, effective-index method, and beam propagation method were used to model the propagation of light in …

    ubc Repository record for Electrooptic mach-zehnder modulators in gallium arsenide (opens in a new tab) Download PDF for Electrooptic mach-zehnder modulators in gallium arsenide (opens in a new tab)

  6. Detonation Realization in a Reacting Mach Stem

    … detonation mode of combustion through a reacting Mach stem. The detonation is experimentally realized in a hypersonic reacting facility, which is optimized for Mach 5 flow at the combustor inlet and includes a 2D-wedge to stabilize hypersonic reactions at high-enthalpy flow conditions. The Mach …

    ucf Repository record for Detonation Realization in a Reacting Mach Stem (opens in a new tab)

  7. Complex Mach reflection in shock diffraction problems

    … The solutions were computed for the complex Mach reflection (CMR) regime of the shock diffraction problem is an attempt to explore the basic physical process governing the evolution of an incipient second Mach stem and the associated topological changes. Numerical results were obtained for …

    iastate Repository record for Complex Mach reflection in shock diffraction problems (opens in a new tab)

  8. Quadrature-point stabilization of Mach-Zehnder interferometers

    … transducer in the reference arm of an all-fiber Mach-Zehnder interferometer.

    vt Repository record for Quadrature-point stabilization of Mach-Zehnder interferometers (opens in a new tab)

  9. Mach flow angularity probe curve fitting/calibration routine

    <p>A method of calibrating five-hole probes (mach flow angularity probes) that are used to measure local flow angles and Mach numbers in a flow field has been developed. Using a least squares curve fitting program, the misalignment angles of a mach flow angularity probe are determined using …

    ut-knoxville Repository record for Mach flow angularity probe curve fitting/calibration routine (opens in a new tab)

  10. Mach - Zehnder tipo interferometro integravimas į optinį šviesolaidį /

    … An example of fiber - optic sensor is Mach - Zehnder interferometer, which has attracted a great deal of interest due to its high sensitivity and high fringe visibility. This thesis describes the formation of MZI cavity using UV (206 nm) fs pulses. Firstly, the optimum ablation …

    vilnius Repository record for Mach - Zehnder tipo interferometro integravimas į optinį šviesolaidį / (opens in a new tab)

  11. Role of Hypervelocity Mach Numbers on Optical Distortion

    … a study comparing effects at three hypersonic Mach numbers simulated at true flight conditions was conducted. A highly modifiable wedge model and a beam distortion imaging technique were designed and implemented in Texas A&M University’s Hypervelocity Expansion Tunnel. Additionally, optical …

    tamu Repository record for Role of Hypervelocity Mach Numbers on Optical Distortion (opens in a new tab)

  12. Polymer Mach-Zehnder interferometers for refractive index sensing

    This thesis presents polymeric Mach-Zehnder interferometers (MZI) for refractive index sensing. These interferometers are designed as asymmetric Mach-Zehnder interferometers (AMZIs), meaning that, when compared with the conventional MZI, the devices have no interaction window on the sensing arm. …

    freiburg-diss Repository record for Polymer Mach-Zehnder interferometers for refractive index sensing (opens in a new tab)

  13. HOT WIRE ANEMOMETRY IN COLD MACH 4 FLOW

    … Naval Postgraduate School operates a cold-flow Mach 4 supersonic wind tunnel, which was renovated in 2022 to improve flow conditioning. Following the upgrades, flow recharacterization was conducted with an emphasis on quantifying turbulence, with turbulence intensity identified as the primary …

    nps Repository record for HOT WIRE ANEMOMETRY IN COLD MACH 4 FLOW (opens in a new tab)

  14. The design and construction of a Mach interferometer

    Thesis (M.S.)--Michigan State College of Agriculture and Applied Science. Dept. of Physics and Astronomy, 1949

    msu Repository record for The design and construction of a Mach interferometer (opens in a new tab)

  15. Hydrodynamic flowfield visualization studies of a Mach 6 waverider

    Flowfield visualization studies of a conical flow derived waverider were conducted in the Naval Postgraduate School water tunnel facility, as part of an ongoing study by the Naval Postgraduate School and the NASA Ames Research Center. The model, with an 8 inch root chord, 7.5 inch span and an …

    nps Repository record for Hydrodynamic flowfield visualization studies of a Mach 6 waverider (opens in a new tab)

  16. Automatic tuning circuits for Mach-Zehnder interferometer optical switches

    … role is in implementing network switches. A Mach-Zehnder interferometer (MZI) is an optical device that is ideally suited to build network switches, as it can be dynamically controlled to achieve high-quality switching of optical signals. However, the performance of silicon photonics devices …

    ubc Repository record for Automatic tuning circuits for Mach-Zehnder interferometer optical switches (opens in a new tab) Download PDF for Automatic tuning circuits for Mach-Zehnder interferometer optical switches (opens in a new tab)

  17. A Mach-Zehnder interferometer with a laser light source

    A Mach-Zehndcr interferometer using a helium-neon laser and a high speed closed-open-closed shutter was designed and constructed in the present plasma facility in the Department of. Mechanical and Aerospace Engineering and Materials Science for use in conjunction with the glow discharge shock tube …

    rice Repository record for A Mach-Zehnder interferometer with a laser light source (opens in a new tab)

  18. MACH: A model for explaining molecular and cellular mechanisms

    … These themes formed the components of the MACH model, which extends previous models of molecular explanations and identifies components to include when teaching students how to explain biological mechanisms. ^ Then a teaching intervention using the MACH model was implemented in an …

    purdue-thes Repository record for MACH: A model for explaining molecular and cellular mechanisms (opens in a new tab)