Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 14 of 14 for “"Mach-Zehnder Interferometry"”.
-
Experimental Investigation of Compliant Wall Surface Deformation in a Turbulent Channel Flow using Tomographic Particle Image Velocimetry and Mach-Zehnder Interferometry
… image velocimetry to measure the flow with Mach-Zehnder interferometry to map the deformation. The Reynolds number is Reτ=2300, and the Young’s modulus of the wall is 0.93 MPa, resulting in a ratio of shear speed, ct, to the centerline velocity, U0, of 6.8. The 3D distributions of pressure …
-
Measurement of the resolution of a charge-injected device
… source onto a single pixel and the second used Mach-Zehnder interferometry and fast Fourier transform-based image processing to characterize the frequency response of the CID2710 camera. The first method investigated was a point source of light focused onto a single pixel in the CID2710 array. …
-
Voltage recovery studies for a high energy spark gap
… (or the temperature variation) was examined by Mach-Zehnder interferometry. The thermal expansion velocity evaluated from the interferograms is about 10^ to 10^ cm/s. The spatial position of the pulse pair with different delay times has been observed for plane electrodes. The results show that …
-
Second-order nonlinearity studies on organic polymeric materials
… presence of a high electric field. Finally, the Mach Zehnder interferometry technique has also been used to determine the Pockels and Kerr coefficients.
-
Mechanisms affecting the interaction between turbulent boundary layers and compliant surface deformation
… and pressure fields are performed by integrating Mach Zehnder Interferometry with Tomographic Particle Tracking Velocimetry. The conditionally averaged 3D flow structures involve a spanwise vortex with a laterally inward flow above a bump, inducing a sweeping diverging flow above the dimple. …
-
Transverse ionizing shock waves in a planar electromagnetic shock tube
… and the gasdynamic regimes. A new method of Mach Zehnder interferometry, using multi-channel spectra, was used to obtain more accurate measurements, of the electron density and the density ratio, than could be attained by conventional M-Z methods. An approximate probe theory was developed to …
-
Study of the 14N(α,γ)18F reaction with the new Felsenkeller gas-jet target
… The gas-jet was fully characterized using Mach–Zehnder interferometry, α-particle energy-loss measurements, and computational fluid dynamics simulations, demonstrating stable operation and well-defined thickness. The jet geometry enables precision studies of narrow resonances and γ-ray …
-
Development of an integrated photonic sensor for monitoring hazardous organics
… of the sensor is based on the principles of the Mach-Zehnder interferometry. The sensor consists of a patterned waveguide structure made of phosphosilicate core and silica cladding. LPCVD processes were developed to produce undoped cladding and doped core silicon dioxide films. Diethylsilane …
-
A Study on the Dynamic Manipulation of Structured Light Using Orbital Angular Momentum for Wireless Underwater Links
… propagation kernel: concentric phase plates, Mach-Zehnder Interferometry, and the HOBBIT (Higher Order Bessel Beams Integrated in Time). These three systems are used to examine the modal integrity, controllability, and unique applications. Structured CCOAM modes were first demonstrated using a …
-
Experiments on dynamic fracture and friction
… near the slip pulse and the orientation of the Mach lines suggestion the slip pulse propagates at a speed close to the dilatational wave speed. Finally, new optical method in which the classical methods of photoelasticity and Mach-Zehnder interferometry are used in a combined arrangement is …
-
Rare earth technology: magnetic cooling and magnetic separation
… By means of particle image velocimetry and Mach-Zehnder interferometry, the flow field and its impact on the heat transfer at the gadolinium plate is analyzed. For the magnetization stage, a heat transfer enhancement by about 40 % can be achieved even with low currents of 3 mA is found. In …
-
Οπτικοί βιοαισθητήρες για την ανίχνευση βιομορίων χωρίς τη χρήση ιχνηθετών
… and evaluate an optical immunosensor based on Mach-Zehnder Interferometry and integrated on silicon substrate for the immunochemical determination of clinical analytes. The optical sensor developed is fabricated entirely by mainstream silicon technology by the Optical Biosensors group of the …
-
Optical immunosensors for the detection of harmful agents in food
… application of an advanced optical Broad-Band Mach-Zehnder Interferometric (MZI) immunosensor for the detection of milk adulteration, aflatoxin M1 (AFM1), Salmonella typhimurium, and Escherichia coli O157:H7 in milk. The sensor is based on silicon chips integrating two U-shaped silicon nitride …
-
Οπτικοί αισθητήρες για χημικούς / βιολογικούς προσδιορισμούς υλοποιημένοι με μικροτεχνολογία πυριτίου
… on silicon, which can incorporate monolithically Mach-Zehnder interferometers advantages, by employing silicon technology. The aim of the thesis is the design, fabrication and characterization of a new integrated optical sensing device for biochemical analysis. The final device consists of the …