Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 189 for “"Magnetic Flux Density"”

  1. A Magnetic Flux Density Control System for the Birdcage Resonator

    … used for over ten years to produce a rotating magnetic flux density for the excitation process necessary for Magnetic Resonance Imaging (MRI). Patients will load the birdcage differently which necessitates the calibration of transmit power on a per patient basis. The method to perform this …

    marquette Repository record for A Magnetic Flux Density Control System for the Birdcage Resonator (opens in a new tab)

  2. Transmission Line Conductor Surface Voltage Gradient and Magnetic Flux Density Computations

    This paper is a documentation of the design process for The Ohio State University Theatre's production of Dancing At Lughnasa. The aim of the design was to enhance the director's concept in creating a vital and energetic play that the characters could bounce back and forth between the world of …

    ohiolink Repository record for Transmission Line Conductor Surface Voltage Gradient and Magnetic Flux Density Computations (opens in a new tab)

  3. Magnetic resonance current density imaging using one component of magnetic flux density

    Magnetic Resonance Electrical Impedance Tomography (MREIT) algorithms using current density distribution have been proposed in the literature. The current density distribution can be determined by using Magnetic Resonance Current Density Imaging (MRCDI) technique. In MRCDI technique, all three …

    metu Repository record for Magnetic resonance current density imaging using one component of magnetic flux density (opens in a new tab)

  4. Performance evaluation of magnetic flux density based magnetic resonance electrical impedance tomography reconstruction algorithms

    Magnetic Resonance Electrical Impedance Tomography (MREIT) reconstructs images of electrical conductivity distribution based on magnetic flux density (B) measurements. Magnetic flux density is generated by an externally applied current on the object and measured by a Magnetic Resonance Imaging …

    metu Repository record for Performance evaluation of magnetic flux density based magnetic resonance electrical impedance tomography reconstruction algorithms (opens in a new tab)

  5. Improving Current Density Recovery and Magnetic Flux Density Imaging in Diffusion Tensor Magnetic Resonance Electrical Impedance Tomography Applications

    … conductivity of biological tissues through Magnetic Resonance Imaging (MRI). Diffusion Tensor Magnetic Resonance Electrical Impedance Tomography (DT-MREIT) is an emerging modality that utilizes a linear relationship between the diffusion tensor and the conductivity tensor and the current …

    metu Repository record for Improving Current Density Recovery and Magnetic Flux Density Imaging in Diffusion Tensor Magnetic Resonance Electrical Impedance Tomography Applications (opens in a new tab)

  6. Development of reconstruction algorithms for magnetic resonance-electrical impedance tomography and experimental realization

    … Impedance To mography (EIT) technique with magnetic flux density measurements acquired using Magnetic Resonance Imaging (MRI) technique. Three reconstruction algorithms for MR-EIT are developed and implemented. Proposed algorithms are grouped into two: current density based reconstruction …

    metu Repository record for Development of reconstruction algorithms for magnetic resonance-electrical impedance tomography and experimental realization (opens in a new tab)

  7. Magnetic Field Analysis of Asymmetric, High-Pass Imaging Structures Based on Theoretical Current Distributions

    Magnetic flux density contours developed by quadraturedriven, Nuclear Magnetic Resonance (NMR) radio frequency coils are investigated. Experimental data is obtained from symmetric and asymmetric structures of both circular and elliptical cross section. Said field profiles are analytically analyzed …

    marquette Repository record for Magnetic Field Analysis of Asymmetric, High-Pass Imaging Structures Based on Theoretical Current Distributions (opens in a new tab)

  8. Finite Element Analysis Based Modeling of Magneto Rheological Dampers

    … is to show a 2-D MR damper and generate the magnetic flux density along the MR Fluid gap. We can detect saturation by looking at the nodal solution for the magnetic flux density. Increasing the current in the model, results in an increase in magnetic induction. We studied four different …

    vt Repository record for Finite Element Analysis Based Modeling of Magneto Rheological Dampers (opens in a new tab)

  9. Avaliação teórico-experimental de campos magnéticos nas proximidades das linhas de transmissão subterrâneas

    … of underground transmission lines to reduce the magnetic flux density around them, while in the design stage. By optimizing the geometry, the magnetic flux density can be effectively reduced without increasing the costs of the layout of the facility, either in material, labor, equipment and …

    brazil-ufmg Repository record for Avaliação teórico-experimental de campos magnéticos nas proximidades das linhas de transmissão subterrâneas (opens in a new tab)

  10. A labview interface to integrate magnetic resonance imaging (MRI) simulator with system control and its application to regional magnetic resonance electrical impedance tomography (MREIT) reconstruction

    Magnetic resonance imaging (MRI) is a high resolution medical imaging technique based on distinguishing tissues according to their nuclear magnetic properties. Magnetic resonance electrical impedance tomography (MREIT) is a conductivity imaging technique which reconstructs images of electrical …

    metu Repository record for A labview interface to integrate magnetic resonance imaging (MRI) simulator with system control and its application to regional magnetic resonance electrical impedance tomography (MREIT) reconstruction (opens in a new tab)

  11. Thermal-magnetic finite element model of a high frequency transformer

    In high-frequency power transformers, magnetic material properties cannot be assumed to be constant. These properties vary with frequency, temperature, and magnetic flux density. Heat generation is, in turn, a function of the magnetic permeability, magnetic flux density, and frequency. Current …

    vt Repository record for Thermal-magnetic finite element model of a high frequency transformer (opens in a new tab)

  12. Compression Mode Characterizations of Magnetorheological Elastomers

    … necessitates compensation for the magnetic force developed by the electromagnet in order to extract viscoelastic force from the measured force. In this dissertation research, a systematic methodology and a mathematical model are developed for compensating for the magnetic force for …

    concordia

  13. Modelling of electron beam deflection system for beam position control in metal additive manufacturing

    … beam deflection system, which uses electromagnetic poles to deflect the beam to a desired position on the build plate. This thesis presents an electron beam deflection system model, which can predict the beam position during EBM operation. The current behavior within the deflection coils is …

    ubc Repository record for Modelling of electron beam deflection system for beam position control in metal additive manufacturing (opens in a new tab)

  14. Συμβολή στην ανάλυση του ηλεκτρικού και του μαγνητικού πεδίου στο περιβάλλον εναέριων γραμμών ηλεκτρικής ενέργειας

    … approximate formulas for the calculation of the magnetic flux density produced by double-circuit lines. For the development of those formulas the use of double complex numbers is combined with the multipole expansion to express the magnetic flux density.

    greece Repository record for Συμβολή στην ανάλυση του ηλεκτρικού και του μαγνητικού πεδίου στο περιβάλλον εναέριων γραμμών ηλεκτρικής ενέργειας (opens in a new tab)

  15. The Use of Metasurfaces for Magnetic Resonance Imaging Applications

    … transceiver coil to improve the radio frequency magnetic field for 1.5T magnetic resonance imaging applications is presented. The novel transceiver provides localized enhancement in magnetic flux density when compared to a transceiver coil alone by incorporating an electrically small metasurface …

    whiterose Repository record for The Use of Metasurfaces for Magnetic Resonance Imaging Applications (opens in a new tab)

  16. Vibration-based electromagnetic energy harvesters for MEMS applications

    This thesis investigates vibration-based electromagnetic energy harvesters (EMEHs) for application in low power autonomous sensors. It makes contributions pertaining to the development of a low cost fabrication technology, analytical modeling, simulations and characterization of EMEHs under …

    ubc Repository record for Vibration-based electromagnetic energy harvesters for MEMS applications (opens in a new tab)

  17. Synthesis and properties of cadmium manganese ferrites

    … phase of Cd₀.₅Mn₀.₅Fe₂O₄ with a bulk sintered density of 98-99% of the X-Ray density. The rate of changing density followed the relationship, p = K ln t + c, at temperatures between 1050°C and 1300°C. Magnetic properties of CdₓMn₁₋ₓFe₂O₄ were affected by composition x. A relationship, B = gx + …

    must-thes Repository record for Synthesis and properties of cadmium manganese ferrites (opens in a new tab)

  18. An Electromagnetic Coupling Model for Side-Channel Analysis

    … Kalman filter is used to combine measurements of magnetic flux density with voltage or current traditionally used to measure power consumption. The DES encryption algorithm is used to evaluate CPA using EM coupled power measurements compared to traditional power measurements.

    utahstate Repository record for An Electromagnetic Coupling Model for Side-Channel Analysis (opens in a new tab)

  19. CFRP Delamination Density Propagation Analysis by Magnetostriction Theory

    … material is born by embedding microscopic magnetically activated sensors between CFRP ply. Magnetostrictive Carbon Fiber Reinforced Polymer (MagCFRP) is a self-sensing structural health composite material that is magnetically activated by an external magnetic field. This research merges the …

    clemson Repository record for CFRP Delamination Density Propagation Analysis by Magnetostriction Theory (opens in a new tab)

Page 1 of 10