Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Magnetic lens"”

  1. A thin magnetic lens beta-ray spectrometer

    Thesis (M.S.)--Michigan State College of Agriculture and Applied Science, 1958

    msu Repository record for A thin magnetic lens beta-ray spectrometer (opens in a new tab)

  2. Magnetic lens design for an ultrafast electron diffraction beamline

    … fundamentals of charged particle imaging with magnetic fields are discussed, and lenses appropriate for use in the space-charge dominated electron be are described.

    mcgill Repository record for Magnetic lens design for an ultrafast electron diffraction beamline (opens in a new tab)

  3. External, internal and nuclear pair measurements with a magnetic lens pair spectrometer

    Magnetic beta-ray spectrometers of several types have been used extensively to obtain information by the detection of low energy gamma-rays. The photoelectric effect, Compton scattering, and atomic internal conversion have yielded information regarding nuclei energy level spacings, transition …

    rice Repository record for External, internal and nuclear pair measurements with a magnetic lens pair spectrometer (opens in a new tab)

  4. Set up of a short magnetic lens electron spectrometer and investigation of cesium-137 and thulium-170 decay.

    … contains the discussion on the set up of a short magnetic lens electron spectrometer, and the results of an investigation of the beta decay spectra of Cs137 and Tm170. A short magnetic lens electron spectrometer of about 21cm focal length was set up and used during the course of this …

    ottawa-retro Repository record for Set up of a short magnetic lens electron spectrometer and investigation of cesium-137 and thulium-170 decay. (opens in a new tab)

  5. Pair spectrograph measurements of the radiations from the deuteron bombardment of boron-10, carbon-12, and fluorine-19 and the proton bombardment of boron-11 and fluorine-19

    … the resolution of complicated spectra. The magnetic lens spectrometer is suited for pair measurements because of its large efficiency for transmitting pairs relative to most other types of spectrometers. Previous measurements have been made with magnetic lens pair spectrometers by Bame and …

    rice Repository record for Pair spectrograph measurements of the radiations from the deuteron bombardment of boron-10, carbon-12, and fluorine-19 and the proton bombardment of boron-11 and fluorine-19 (opens in a new tab)

  6. Measurement of the Focal Properties of a Magnetic Electron Lens Using the Shadowgraph Method

    … experimentally determining the properties of a magnetic electron lens is presented. The method uses the shadows cast by two meshes, one placed in front of the lens and one behind the lens, to study the properties of the image of a point source. The lens properties are then calculated from the …

    portland-state Repository record for Measurement of the Focal Properties of a Magnetic Electron Lens Using the Shadowgraph Method (opens in a new tab)

  7. Manipulation of ultracold atoms using magnetic and optical fields

    … at the apex of the motion by using a single magnetic impulse to achieve axial focusing. A theoretical study of six current-carrying coil and bar arrangements that generate magnetic lenses is made. An investigation of focusing aberrations show that, for typical experimental parameters, the …

    durham Repository record for Manipulation of ultracold atoms using magnetic and optical fields (opens in a new tab)

  8. The design and development of a time-resolved electron diffractometer for the investigation of molecular dynamics

    … beam produced, and how this varies as a solenoid magnetic lens acts to focus the beam. An optimal FWHM beam width of 1.2 mm has been observed at the detector for pulses containing 10^4 electrons. The time-zero position between a pump laser and probe electron beam has been found by studying the …

    whiterose Repository record for The design and development of a time-resolved electron diffractometer for the investigation of molecular dynamics (opens in a new tab)

  9. The disintegration of hafnium of mass 181.

    … of 46 day Hf181 has been made using a thin magnetic lens spectrometer. The beta-spectrum has an apparent end-point of 0.419 ± 0.024 Mev but because of the presence of conversion lines could not be analyzed for complexity. Conversion lines at 64 ± 0.6, 118 ± 1, 269 ± 3, 404 ± 4 and 457 ± 5 …

    mcgill Repository record for The disintegration of hafnium of mass 181. (opens in a new tab)

  10. An ultracold high-flux source for matter-wave interferometry in microgravity

    … has demanding requirements regarding the magnetic field environment, the control over the position and the velocity of the atomic ensemble as well as its velocity spread. All these points are systematically and thoroughly investigated. An ultrasmall velocity spread of 140μm/s equivalent to …

    oldenburg Repository record for An ultracold high-flux source for matter-wave interferometry in microgravity (opens in a new tab)

  11. Pair spectrograph measurements of the radiations from deuteron bombardment of carbon-13, nitrogen-14, beryllium-9, lithium-7, and boron-11

    … been expended to improve the performance of a magnetic lens pair spectrometer for gamma-ray measurements. Sufficient progress has been made so that it was thought worth while to survey the gamma-rays from a number of nuclear reactions with the instrument in its present form. The results …

    rice Repository record for Pair spectrograph measurements of the radiations from deuteron bombardment of carbon-13, nitrogen-14, beryllium-9, lithium-7, and boron-11 (opens in a new tab)

  12. Reconstruction of thin lens Beta ray spectrometer

    … was to redesign and make operational a thin magnetic lens Beta-ray spectrometer which could be used to determine the beta particle spectrum emitted by radioisotopes. Since to date, data concerning the theory, operation, construction, calibration and uses of this type spectrometer is scattered …

    nps Repository record for Reconstruction of thin lens Beta ray spectrometer (opens in a new tab)

  13. Simulating the Electron Optics of an Electron Beam Manufacturing 3D Printer

    … that utilizes an electron beam, controlled by a magnetic lens system, to melt metal powder. GE is currently looking into opportunities for simulating the Electron Optics, with the ambition to further develop their EBM technology. In this project a model of the lens system has been built and …

    chalmers Repository record for Simulating the Electron Optics of an Electron Beam Manufacturing 3D Printer (opens in a new tab)

  14. Atom interferometry with picokelvin ensembles in microgravity

    … ideal input states. Therefore a method called magnetic lensing is used to narrow the momentum distribution. Together with the very good coherence properties of BECs, this reduces uncertainties in the interferometric measurement and enables high-fidelity beam splitter processes like Bragg …

    bremen Repository record for Atom interferometry with picokelvin ensembles in microgravity (opens in a new tab)

Page 1 of 2