Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"Magnetic motor"”

  1. Rattlesnake nanoactuator - a precision high speed closed loop linear actuator with capacitive sensor

    … based on a closed loop tightly integrated magnetic motor and capacitive sensor. Mechanical, electrical and software work has resulted in a device achieving a mechanical range of travel of ±1mm with a steady state RMS error of 62nm at a closed loop bandwidth of 3.5kHz, a typical tracking …

    chalmers Repository record for Rattlesnake nanoactuator - a precision high speed closed loop linear actuator with capacitive sensor (opens in a new tab)

  2. Approximate dynamic programming and artificial neural network control of electric vehicles: from motor drives to grid integration

    … of the powertrain control is to control the EV motor, which is usually an interior mounted permanent magnetic motor(IPM). By using the conventional vector controller, the IPM encounters high current distortion and speed oscillation especially when working in overmodulation area, due to the …

    alabama Repository record for Approximate dynamic programming and artificial neural network control of electric vehicles: from motor drives to grid integration (opens in a new tab)

  3. Magnetický motor

    … analyzovány a vzájemně porovnávány vybrané druhy magnetických motorů. U každého motoru je uveden krátký popis a kritické zhodnocení jeho vlastností. V další části jsou všechny magnetické motory porovnány a je vybrán typ motoru pro simulaci. Simulace jsou provedeny v programech COMSOL Multiphysics …

    brno-tech Repository record for Magnetický motor (opens in a new tab)

  4. Cervical Spondylomyelopathy in the Great Dane Breed: Anatomic, Diagnostic Imaging, Functional, and Biochemical Characterization

    … radiography, computed tomography (CT) and magnetic resonance imaging (MRI) of the cervical vertebral column, transcranial magnetic motor evoked potential (TMMEPs), and cerebellomedullary cistern CSF collection. This thesis consists of seven experiments aimed at expanding the current …

    ohiolink Repository record for Cervical Spondylomyelopathy in the Great Dane Breed: Anatomic, Diagnostic Imaging, Functional, and Biochemical Characterization (opens in a new tab)

  5. Novel Artificial Urinary Sphincter for Stress Urinary Incontinence Treatment

    The American Medical System’s AMS 800TM has been the gold standard for over 40 years with over 150,000 patients treated for Urinary Incontinence and is the leading treatment for male stress urinary incontinence (SUI) following prostate surgery. Type III SUI, or intrinsic sphincter deficiency, is …

    umn Repository record for Novel Artificial Urinary Sphincter for Stress Urinary Incontinence Treatment (opens in a new tab)