The inverse problem of Magnetocardiography
In order to reconstruct the electrical activity in the heart this work employs the method activation time imaging. In the method first the primary current dipoles distributed on a cubic ventricular grid with a lattice constant of 1.5 mm are calculated from the measured magnetocardiographic signal …
-
Advanced Source Reconstruction and Volume Conductor Modeling for Fetal Magnetocardiography
… of this thesis is to develop and test fetal magnetocardiography (fMCG) techniques as an alternative diagnostic tool for the detection and monitoring of the fetal heart. fMCG is a novel technique that records the magnetic fields generated by the fetal heart's electric activity. From the aspect …
-
Magnetocardiography in unshielded environment based on optical magnetometry and adaptive noise cancellation
This thesis proposes and demonstrates the concept of a magnetocardiographic system employing an array of optically-pumped quantum magnetometers and an adaptive noise cancellation for heart magnetic field measurement within a magnetically-unshielded environment. Optically-pumped quantum …
-
The cardiomagnetic field: Non-invasive mapping of atrial fibrillation and model-based characterization of sensitivity and resolution
… activity of the heart gives rise to. In magnetocardiography (MCG), the cardiomagnetic field is measured outside the thorax and analyzed. In this Thesis, I have studied and developed multichannel MCG mapping in order to characterize the cardiac function and AF. The cardiomagnetic field was …
-
Modulation Technique for Magneto -Optic Imaging of Weak Magnetic Fields With Rare-Earth Iron Garnet Films
… of interest for biomagnetic imaging, including magnetocardiography for diagnosis of cardiac anomalies and imaging of magnetic nanoparticles for cancer diagnosis and studies of drug delivery mechanisms. Dynamic detection of ferromagnetic nanoparticles is also demonstrated. Studies of system noise …
-
Development of a Low Cost Bio-magnetometer for the Detection of Myocardial Infarction
… and low cost magnetometer for cardiac imaging. Magnetocardiography (MCG) involves capturing magnetic field maps (MFM's) of current distributions resulting from cardiac action potentials. Particular emphasis was given to the diagnostic performance of distinguishing cardiac patients, mainly with …
-
Use of Multiscale Entropy to Characterize Fetal Autonomic Development
… most recent and developed methods such as fetal magnetocardiography (fMCG), investigators are continuously challenged to study fetal development; the fetus is inaccessible. Finding metrics that realize the full capacity of characterizing fetal ontological development remains a technological …
-
AlN vs. AlScN in Magnetoelectric Sensors
… in the heart, brain or muscles, also known as magnetocardiography (MCG), magnetoencephalgraphy (MEG) and magnetomyography (MMG), can provide a powerful diagnosis of heart, brain or muscle function. State-of-the-art magnetometers for biomagnetic field measurement are ultrahigh sensitive …
-
The magnetostatic multipole expansion in biomagnetism: applications and implications
… to other biomagnetic measurements, such as magnetocardiography.
-
Applications of Optics in Non-Traditional Biomedical Imaging
… being used in Magnetoencephalography (MEG) and Magnetocardiography (MCG) systems. Using this method high spatiotemporal mapping of biological activities can be achieved in an un-shielded environment.
-
Magneto-Optic Polymers and Devices
… sensing, crucial for magnetoencephalography and magnetocardiography; and compact and efficient optical isolators, among others. In the past, many of these applications and the devices designed for them have heavily relied on inorganic materials. Organic materials with a high MO response represent …
-
A Biomagnetic Field Mapping System for Detection of Heart Disease in a Clinical Environment
… pain and the untapped diagnostic potential of magnetocardiography (MCG) to reliably detect silent ischaemic heart disease, which is responsible for the highest mortality rate of any single disease category. The aim was to develop a low cost and portable biomagnetic field mapping system capable …
-
Data registration and fusion for cardiac applications
… and the registration of MR images with magnetocardiography (MCG) data using external markers. The method resulted in a 3-D anatomical and functional model of the heart that included structural information from the MRI and functional information from the PET and MCG. Different error …
-
Cardiac exercise studies with bioelectromagnetic mapping
… exercise testing. In a more recent technique, magnetocardiography (MCG), the cardiac magnetic field is recorded in the vicinity of the chest. Despite the clinical significance of the exercise ECG recordings in patients with suspected coronary artery disease (CAD), little is known about the …
-
BioMEMS for cardiac tissue monitoring and maturation
… magnetic field. This has an ideal application in magnetocardiography (MCG), as the flux of ions during cardiac contractions produces measurable magnetic signals around the tissue and can be leveraged for noncontact diagnosis. The second is a highly functionalized heart-on-a-chip platform, wherein …
-
Converse Magnetoelectric Resonators for Biomagnetic Field Sensing
… novel diagnostic abilities using multichannel magnetocardiography (MCG) and magnetoencephalography (MEG) either as a single source of information for rapid patient screening or in combination with established methods such as electrocardiography (ECG) and electroencephalography (EEG) as a source …
-
Source characterization using linear transformation of multichannel biomagnetic recordings
… via magnetoencephalography (MEG), and heart, via magnetocardiography (MCG). Dense-array biomagnetometers have been recently designed for the investigation of the neurophysiological development of the fetus in utero. Fetal MCG offers accurate recordings of the fetal cardiac activity that allow to …
-
Der Einfluss des elektrischen Remodelings während des akuten und chronischen Myokardinfarktstadiums der Ratte auf das Magnetokardiogramm
Der Hintergrund für diese Studie stellt die hohe Inzidenz von Myokardinfarkten in den Industrieländern und den damit verbundenen Folgen wie z.B. die hohe Mortalität durch maligne Herzrhythmusstörungen dar. Ziel dieser vorliegenden Arbeit war es, an einem Infarktmodell für die Ratte das …
-
Die Entwicklung des myokardialen Hypertrophiebildes im Magnetokardiogramm und die Veränderungen unter dem AT1-Antagonisten Losartan in einem transgenen Rattenmodell
Ziel dieser Arbeit war es, Aussagen über das elektrische Remodeling der myokardialen Hypertrophieentwicklung an doppeltransgenen Ratten (Überexpression von humanen Renin und Angiotensinogen) mit Hilfe der Magnetokardiographie (MKG) zu treffen, und die Veränderung unter Losartantherapie zu …
-
Die Anwendung der Magnetokardiographie zur Detektion von nicht-ischämischen Kardiomyopathien und deren Zusammenhang mit Alter, Geschlecht und Body-Mass-Index
Einleitung: Nicht-ischämische Kardiomyopathien bilden eine große und heterogene Gruppe unterschiedlicher Erkrankungen des Herzmuskels. Aufgrund der variablen Symptompräsentation und Ursachen der Erkrankungen stellen sie im klinischen Alltag eine diagnostische Herausforderung dar und werden nicht …