Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Majorana demonstrator"”
-
Muon Intensity Measurement with the Majorana Demonstrator
The Majorana Demonstrator (MJD) is a shielded radiation detection system located a mile underground at the Sanford Underground Research Facility (SURF) in South Dakota. The system aims to detect the theorized, rare process of neutrinoless double-beta decay. The Demonstrator utilizes an array of …
-
An Axion Search With The Majorana Demonstrator
The Majorana Demonstrator is an array of P-type point contact (PPC) germanium detectors enclosed in a multi-layered shield at the 4850’ level of the Sanford Underground Research Facility. Its primary goal is to search for the neutrinoless double beta decay of 76Ge. The initial 10 kg-y dataset, …
-
In Situ Cosmogenic Backgrounds in the MAJORANA DEMONSTRATOR
… its own antiparticle otherwise known as a Majorana particle?", "What is the mass of the neutrino?", and "What is the neutrino mass hierarchy?" As technology and experimental techniques improve, the sensitivity of experiments looking for rare events becomes more dependent on the backgrounds. …
-
A Radiogenic Background Model for the MAJORANA DEMONSTRATOR
… existence would indicate that neutrinos are Majorana fermions. The MAJORANA collaboration is searching for 0vbb in germanium-76 using a modular array of high-purity germanium (HPGe) detectors with support and shielding constructed from low-background materials and housed at the 4850' level of …
-
Recovering Lost Exposure From the Majorana Demonstrator and Testing Data Selection Assumptions
The Majorana Demonstrator recently concluded its search for neutrinoless double beta decay using an array of up to 40.4kg of germanium detectors, 27kg of which were enriched in 76Ge and housed inside a copper and lead compact shield located at the 4850 foot level in a clean room in the Davis Campus …
-
Search for Neutrinoless Double Beta Decay Using the Full Majorana Demonstrator Dataset
The \textsc{Majorana} Collaboration is searching for the neutrinoless double-$\beta$ decay of $^{76}$Ge. The \textsc{Majorana Demonstrator} consists of two modular arrays of high-purity Ge detectors operated in vacuum cryostats housed in a low-background shield at the Sanford Underground Research …
-
The Search for Double-Beta Decay to Excited States in 76-Ge using the MAJORANA DEMONSTRATOR
… that the neutrino is granted mass by the Majorana mechanism, and provide a means of measuring the mass scale of the neutrino. This would also provide a means for violating Lepton number conservation in the Standard Model, potentially enabling a mechanism for the asymmetric creation of more …
-
Pulse fitting for event localization in high purity germanium point contact detectors
… backgrounds and low energy thresholds. The Majorana collaboration operates the Majorana Demonstrator experiment, which uses high purity germanium (HPGe) point contact (PPC) detectors with the goal of experimentally observing neutrinoless double-beta decay. Neutrinoless double-beta decay is …
-
Surface Alpha Interactions in P-Type Point-Contact HPGe Detectors: Maximizing Sensitivity of 76Ge Neutrinoless Double-Beta Decay Searches
… One intriguing possibility is that neutrinos are Majorana particles, i.e., they are their own anti-particles. Such a mechanism could naturally explain the observed smallness of the neutrino masses, and would have consequences that go far beyond neutrino physics, with implications for Grand …
-
Natural Radioactive Background Suppression in 76Ge Neutrinoless Double-β Decay Experiments
… particle in the Standard Model that could have a Majorana mass. A particle with a Majorana mass is indistinguishable from its anti-particle and gives the possibility for lepton number flavor vio lating reactions to occur. The observation of a Majorana neutrino would demonstrate lepton number …
-
Radon Measurement for Neutrinoless Double Beta Decay
… characterization and mitigation for the MAJORANA DEMONSTRATOR Neutrinoless Double Beta Decay Experiment and Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND) Collaboration. Understanding and mitigating background radiation is especially important in searches …
-
Development of Ultrasensitive Analytical Techniques to Detect Trace Elements
… and U from ultrapure Cu made underground for the Majorana Demonstrator. We made significant advancements on the actinide detection efficiency and sensitivity with the laser-based technique RIMS. We demonstrated that RIMS is a powerful analytical technique for actinides since it does not require …
-
Quasi-Background-Free Neutrinoless Double-Beta Decay Searches with LEGEND: Statistical Methods and Cryogenic SiPM Characterization
… whose Lagrangian mass term could include a Majorana term. The nature of the neutrino mass is exciting because it is inherently Beyond the Standard Model: neutrino oscillations show that the neutrino has a mass and that it violates conservation of individual lepton numbers, in direct …