Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 6 of 6 for “"Mammosite"”
-
Investigation of uncertainties associated with the MammoSite™ Breast Brachytherapy Technique: Monte Carlo simulations and TLD measurements
The MammoSite Radiation Therapy System is a novel brachytherapy technique for treatment of patients with early stage breast cancer. It is used as a sole radiation treatment or in combination with external beam radiotherapy. There are several uncertainties associated with the dose distribution from …
-
Dosimetric Evaluation of Three Partial Breast Irradiation Devices and the Dosimetric Effect of Tissue Thickness Surrounding a Multi-Lumen Partial Breast Applicator
… problem when it comes to treatment with the MammoSite® single lumen breast applicator. A previous Monte Carlo study tested 3 MammoSite® balloon sizes at various depths beyond the planning target volume to see how much tissue would be needed to achieve full scatter. The results showed that on …
-
Quantitative Assessment of Radiation Dosimetry from a MammoSite balloon, FSD Applicator and a Newly Designed HDR Applicator for Treatment of GYN Cancers Using Monte Carlo Simulations
… of three dimensional attenuation presented by Mammosite Balloon in dosimetry of Partial Breast Irradiation. Current treatment planning systems (TPSs) for partial breast irradiation using this applicator often neglects the effect of inhomogeneity, leading to potential inaccuracies in dose …
-
Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
… boost, Strut-Adjusted Volume Implant (SAVI), and Mammosite Multi-lumen (ML).Six points of interest (POI) on the breast cancer patients had been selected for the TLDs placement. Data from 25 breast cancer patients at Lynn Cancer Institute of the Boca Raton Regional Hospital were included in the …
-
Patient-specific dose calculation methods for high-dose-rate iridium-192 brachytherapy
… patient plans for head-and-neck, esophagus, and MammoSite breast brachytherapy. Although the method fails to correct for the changes in lateral scatter introduced by inhomogeneities, it is a major improvement over TG-43 and is sufficiently fast for clinical use.
-
A Novel Device for Delivering Combined Partial Breast Irradiation and Partial Breast Hyperthermia
… using gafchromic film and compared to a standard Mammosite applicator. The PBHI applicator shows increased attenuation, estimated at 3.5 % radially, with a maximum increase in attenuation of 10% in a small region off the tip of the applicator. </p> <p>The homogeneity of the balloon surface …