Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Manometers"”.

  1. A fibre optic based-high resolution manometer with hydrodynamic and contact pressure specificity

    … is a contact phenomenon. Current esophageal manometers are sensitive to both hydrodynamic and contact pressures and cannot distinguish between the two measurements in the absence of other information. It has been shown that measurement of intrabolus pressure is a clinically relevant parameter …

    uvic Repository record for A fibre optic based-high resolution manometer with hydrodynamic and contact pressure specificity (opens in a new tab)

  2. Increasing Documentation of Endotracheal Tube Cuff Pressures: A Quality Improvement Initiative for Flight Crew Providers

    … PowerPoint presentation, charting reminders, and manometers provided for practice and use. AG Cuffill reference materials were placed in a folder at the base for quick reference. The objectives were to deliver ETT CP training to at least 70% of full-time flight crew during a scheduled base meeting …

    wvu Repository record for Increasing Documentation of Endotracheal Tube Cuff Pressures: A Quality Improvement Initiative for Flight Crew Providers (opens in a new tab)

  3. Transitional Phenomena in Oscillating Liquid Columns

    … of free oscillations in liquid-filled U-tube manometers was investigated. The laminar damping coefficients determined were in good agreement with those obtained in previous studies; allowances were made for the secondary flow patterns existing. Two Reynolds numbers were used to characterize …

    mcmaster Repository record for Transitional Phenomena in Oscillating Liquid Columns (opens in a new tab)

  4. Hydrodynamics of the renal pelvis

    … and because, until the 1950's only water manometers were available for measuring intrapelvic pressures. Water manometers record fluid displacent of relatively large volume and so cannot aceurately measure the pressure changes associated with the transport of small volume of urine in the …

    glasgow Download PDF for Hydrodynamics of the renal pelvis (opens in a new tab)

  5. Development of a boundary layer control device for tip clearence experiments in an axial compressor

    … and pressures were recorded manually using water manometers. The geometry of the boundary layer control device, an annular array of spires, was derived from shapes developed for simulating the atmospheric boundary layer in large rectangular section wind tunnels. A significantly thicker boundary …

    nps Repository record for Development of a boundary layer control device for tip clearence experiments in an axial compressor (opens in a new tab)

  6. Characterization and macroscale morphology control of mesoporous alumina molecular sieves

    … pores consisted of unimodal mesopores of several manometers in diameter. Some factors such as reaction temperature, the polarity of solvent and the concentration of surfactant/inorganic precursor assembly, which affect the macroscale morphology control, were investigated and discussed. Finally a …

    iastate Repository record for Characterization and macroscale morphology control of mesoporous alumina molecular sieves (opens in a new tab)

  7. Development of Natural Filling Cystometer and Comparison with Conventional Cystometry

    … and abdominal pressures to the digital manometers. The pressures were stored within the portable computer and turned into graphs indicating pressure changes. The NFC is thought to be a physiological test that is affordable and convenient because of its simple structure and small size. …

    ajou Repository record for Development of Natural Filling Cystometer and Comparison with Conventional Cystometry (opens in a new tab) Embargoed until 9999-12-31

  8. The effect of frost defoliation upon the respiratory rate of the sugar beet root and the oxidases present in the beet root.

    … discs were used in each reaction vessel. Nine manometers were used for the tissue from frost defoliated roots and nine for the controls. Respiration was determined as oxygen uptake and measured by Warburg's direct method. One day after defoliation the respiratory rate of defoliated beets was …

    ubc Repository record for The effect of frost defoliation upon the respiratory rate of the sugar beet root and the oxidases present in the beet root. (opens in a new tab) Download PDF for The effect of frost defoliation upon the respiratory rate of the sugar beet root and the oxidases present in the beet root. (opens in a new tab)

  9. Implementing Best Practice Methods of Endotracheal Tube Cuff Inflation in the Operating Room

    Background: Use of manometers, inflating the endotracheal tube (ETT) cuff with a 5-mL syringe, displaying the pressure-volume loop (PV-L) on anesthesia machines, and auscultating with a stethoscope over the trachea have been shown effective in preventing ETT cuff overinflation in the operating room …

    wvu Repository record for Implementing Best Practice Methods of Endotracheal Tube Cuff Inflation in the Operating Room (opens in a new tab)

  10. Thermodynamic properties of n-butanol

    … were obtained to ± 0.1 per cent. Nitrogen manometers were also used for pressure measurement in some cases but much less successfully. Temperatures were maintained constant within a vacuum jacketed column, and measured by a copper-constantan thermocouple calibrated against a standard …

    ubc Repository record for Thermodynamic properties of n-butanol (opens in a new tab) Download PDF for Thermodynamic properties of n-butanol (opens in a new tab)

  11. Evaluation des Applanationstonometers TonoPen Avia Vet für die Bestimmung des Augeninnendrucks bei Hunden, Katzen und Kaninchen

    … Hund, Katze und Kaninchen mit Hilfe eines Manometers zu kalibrieren. Anhand der Ergebnisse sollte ein Korrekturfaktor bestimmt werden, mit dem der tonometrisch gemessene intraokulare Druck (IOD) in den manometrischen IOD umgerechnet werden kann. Im zweiten Teil der Studie sollten …

    fu-berlin Repository record for Evaluation des Applanationstonometers TonoPen Avia Vet für die Bestimmung des Augeninnendrucks bei Hunden, Katzen und Kaninchen (opens in a new tab)

  12. Estudo da redução de arrasto induzido por polímeros em escoamentos internos turbulentos em dutos

    … of drag reduction, the bench has basically two manometers with a 8.5 psi full scale, a peripheral pump 0.5 HP, an acrylic tank, valves and tubes pvc and is situated in the Laboratory Fluid Mechanics UFRN. Were used as polymer additives to polyethylene glycol 4000, the Polyox WSR N60K, Polyox WSR …

    brazil-ufrn Repository record for Estudo da redução de arrasto induzido por polímeros em escoamentos internos turbulentos em dutos (opens in a new tab)

  13. Some aspects of stratified flow in closed conduits

    … tanks, a receiving tank, flow control valves, manometers, and discharge measuring devices, was built for the above investigations. The equation of motion was derived for the velocity distribution, starting from the Navier-Stokes equations. A special Poisson equation with a constant term on the …

    vt Repository record for Some aspects of stratified flow in closed conduits (opens in a new tab)

  14. Flow patterns on distillation trays

    … the height of clear liquid across the tray with manometers. The flow rates used were designed to show how the flow pattern changed with the change in the gas and liquid rates. The results from water-only studies on an un-perforated tray were compared with those produced on a sieve tray with holes …

    aston Download PDF for Flow patterns on distillation trays (opens in a new tab)

  15. The determination of the operating characteristics of an 18- inch stoneware gas absorption tower

    … stream. Orifices, metering central valves, and manometers were installed in all pipe lines conveying materials to the tower in order to increase the ease and accuracy of controlling the flow of these various materials. After the above changes had been completed, a series of nineteen test runs …

    vt Repository record for The determination of the operating characteristics of an 18- inch stoneware gas absorption tower (opens in a new tab)

  16. The interfacial tension of several hydrocarbons against water

    … filled with the hydrocarbon and serve as manometers. Hutchinson's formula involves a knowledge of the arbitrary constant for the apparatus, the density of the hydrocarbon and the difference in heights of the columns of liquid in the side tubes corresponding to the pressure difference to …

    ubc Repository record for The interfacial tension of several hydrocarbons against water (opens in a new tab) Download PDF for The interfacial tension of several hydrocarbons against water (opens in a new tab)

  17. Gas transport and storage processes in the lacunar system of Egeria densa Planch.

    … in Egeria. However, by connecting shoots into manometers, internal pressure gradients of some 0.9 kPa m-1 were detected. These gradients were 103 -fold greater than the pressure gradient required to account for oxygen transport in Egeria, but were transient features, as the pressure …

    auckland-ms Repository record for Gas transport and storage processes in the lacunar system of Egeria densa Planch. (opens in a new tab)

  18. The design of a commercial plant for the production of ethylene glycol

    … of needle valves and indicated by water filled manometers. The reactant gas mixture was pre-heated prior to passage through the reactor tube. A series of runs was made to determine the effect of ethylene concentration on the oxidation reaction. The temperature was held at approximately 260°C. …

    vt Repository record for The design of a commercial plant for the production of ethylene glycol (opens in a new tab)

  19. The use of flow control devices to improve the flow pattern and throughput of sieve trays

    … across the tray and in the downcomer using manometers. This work presents experiments designed to evaluate flow control devices proposed to improve the gas liquid interaction and hence improve the tray efficiency and throughput. These are (a) the use of intermediate weirs to redirect liquid …

    aston Download PDF for The use of flow control devices to improve the flow pattern and throughput of sieve trays (opens in a new tab)

  20. Identification of Patterns and Controls of the Distribution of Groundwater Discharge to Streams

    … meters, field permeameters, and piezometers and manometers, however the controls for the magnitude and distribution of discharge remain poorly understood. The purpose of this study was to conduct field investigations complimented with numerical analysis to gain a better understanding of the …

    clemson Repository record for Identification of Patterns and Controls of the Distribution of Groundwater Discharge to Streams (opens in a new tab)

Page 1 of 2