Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Marker placement."”.

  1. Binary Directional Marker Placement for Mobile Robot Localization

    … optimally placing binary directional proximity markers to assist a robot as it navigates waypoints through an environment. A simple planar fiducial marker is developed to serve as the binary directional proximity marker. A scoring function is proposed for marker placement as well as a method for …

    uvic Repository record for Binary Directional Marker Placement for Mobile Robot Localization (opens in a new tab)

  2. Fiducial Marker Placement and Selection Study for Real-Time Lung Tumor Tracking

    … in multiple ways, but one way is fiducial marker directed tracking. Tracking helps the tumor to be located and treated continuously in real time. This allows the treatment margins to be smaller and gets better patient outcomes. However, the accuracy of the fiducials' motion matching tumor …

    ecu Repository record for Fiducial Marker Placement and Selection Study for Real-Time Lung Tumor Tracking (opens in a new tab)

  3. Assessing precision and application of marker placement device to enhance motion capture studies.

    … of error within clinical motion capture due to marker replacement. The objective of this study was to develop and evaluate a device that increases the precision of repeatedly placing motion capture markers on a subject for between-day and between-examiner situations. Each mechanical component of …

    baylor Repository record for Assessing precision and application of marker placement device to enhance motion capture studies. (opens in a new tab)

  4. Effects of Two Marker Placement and Data Analysis Methods on Running Gait Analysis

    This study evaluated the effects of two marker placement methods and two data analysis methods on running gait analysis. Markers placed on the shoe heel counter were compared with markers placed directly on the calcaneous and visible through heel windows cut into the shoe. When analyzed using a …

    oregon Repository record for Effects of Two Marker Placement and Data Analysis Methods on Running Gait Analysis (opens in a new tab)

  5. The Use of Real-Time Feedback to Improve Kinematic Marker Placement Consistency Among Novice Examiners

    Marker placement deviation contributes the largest amount of error in gait kinematic data. The study purpose was to determine whether a novel, real-time marker-placement tool could improve consistency of gait kinematic data. Twelve novice examiners placed retroreflective markers on a single runner. …

    calgary Repository record for The Use of Real-Time Feedback to Improve Kinematic Marker Placement Consistency Among Novice Examiners (opens in a new tab)

  6. Reliability of a Multisegment Foot Model in Shod Running

    … of this study was to determine kinematic and marker placement reliability of the Leardini multisegment foot model (LMFM) for tracking foot kinematics during barefoot and shod running without alteration of footwear. Eleven participants, five males (25.6±5 yrs, 73±15.8 kg, 1.75±0.05m) and six …

    unlv Repository record for Reliability of a Multisegment Foot Model in Shod Running (opens in a new tab) Download PDF for Reliability of a Multisegment Foot Model in Shod Running (opens in a new tab)

  7. Repeatability of Kinematic and Kinetic Data in the Analysis of Normal Human Gait

    … to determine how much error existed due to marker placement between trials and testers. Part II of this study assessed the repeatability of one subject’s gait over nine different days to determine the effects of neuromuscular variability on kinematic and kinetic data.. Results showed that …

    gvsu Repository record for Repeatability of Kinematic and Kinetic Data in the Analysis of Normal Human Gait (opens in a new tab)

  8. Walking Speed, Gait Asymmetry, and Motor Variability

    … objectives: 1) determine the repeatability of marker placement, 2) determine the effect of set versus self-selected walking speed, and 3) examine the correlation between gait asymmetry and motor variability. Ten and fifty-one healthy control participants were recruited for aim 1 and aims 2/3, …

    vt Repository record for Walking Speed, Gait Asymmetry, and Motor Variability (opens in a new tab)

  9. Improved Accuracy in Optical Motion Capture Measurements Leads to Increased Sensitivity to Kinematic Changes

    … systems are commonly created by applying markers to the surface of the skin over specific, bony anatomy that is manually palpated. The location and placement of these markers is subjective and precision errors of up to 25mm have been reported [1]. Additionally, the selection of which …

    queens Repository record for Improved Accuracy in Optical Motion Capture Measurements Leads to Increased Sensitivity to Kinematic Changes (opens in a new tab)

  10. Motion tracking and modelling of the forefoot for clinical gait analysis

    … and each differs in terms of segmentation, marker placement protocol, tracking technology, and joint motion. By representing individual segments as a series of linked rigid body segments, the computation and interpretation of foot biomechanics can be greatly simplified. While this approach …

    oxford Repository record for Motion tracking and modelling of the forefoot for clinical gait analysis (opens in a new tab)

  11. An Investigation of Methods to Attenuate Soft Tissue Artifact of the Thigh in High Knee Flexion

    … optical motion capture, or the movement of skin markers relative to bone, is widely accepted as a significant source of error in estimations of angles and moments. In some cases, the error associated with soft tissue movement exceeds that of the physiological motion of the joint, thereby calling …

    waterloo Repository record for An Investigation of Methods to Attenuate Soft Tissue Artifact of the Thigh in High Knee Flexion (opens in a new tab)

  12. Low bit rate DCT-based video coding in error-prone environments

    … a rate-distortion optimized synchronization marker placement algorithm which can effectively determine the frequency and location of synchronization markers, subject to a known decoder concealment method. Next, we present a semi-fixed length coding method for the efficient entropy coding of …

    ubc Repository record for Low bit rate DCT-based video coding in error-prone environments (opens in a new tab) Download PDF for Low bit rate DCT-based video coding in error-prone environments (opens in a new tab)

  13. Practical Considerations for Effective Markerless Motion Capture Research

    … method for analysing whole-body movements is marker-based motion capture. Limitations of marker-based motion capture, however, include marker placement errors, soft tissue artefacts, inter-operator variability, and lack of accessibility. To address these limitations, markerless motion capture …

    queens Repository record for Practical Considerations for Effective Markerless Motion Capture Research (opens in a new tab)

  14. The Effect of Hamstring Lengthening on Pelvic Tilt and Lumbar Lordosis

    … capture laboratory due to subtle differences in marker placement, tissue interface and distribution. Therefore, the purpose of this study was twofold. The first goal was to develop and validate a method that allows accurate comparison of LL measurements from different testing sessions. Secondly, …

    tenn-hsc Repository record for The Effect of Hamstring Lengthening on Pelvic Tilt and Lumbar Lordosis (opens in a new tab)

  15. Kinematic and Kinetic Effects of Alterations in Lumbar Lordosis in People with Tight Hamstrings

    … of this study in a motion analysis lab. First, a marker validation study was conducted to ensure the accuracy of sagittal spinal measures of lumbar lordosis, thoracic kyphosis, and sagittal vertical axis, which are calculated using skin markers. Lateral x-rays taken by the EOS bi-planar scanner …

    tenn-hsc Repository record for Kinematic and Kinetic Effects of Alterations in Lumbar Lordosis in People with Tight Hamstrings (opens in a new tab)

  16. Usability of Markerless Motion Capture for Conducting 3D Instrumented Gait Analysis with Children

    … palsy and other mobility impairments. However, marker-based motion capture —the current clinical standard for conducting 3DGA— may be uncomfortable or even intolerable for many children. Marker-based assessments require the accurate placement of reflective markers on bony landmarks, which …

    calgary Repository record for Usability of Markerless Motion Capture for Conducting 3D Instrumented Gait Analysis with Children (opens in a new tab)

  17. Test-Retest Reliability of Decomposition-Based Quantitative Electromyography Derived Motor Unit Number Estimates

    … MUNE (amplitude/area), and the type of SMUP marker editing (automatic/manual) was investigated in terms of MUNE values. Two separate analyses on a single data set collected from twenty healthy subjects on two occasions were conducted. MUNEs were calculated by dividing a size-related parameter …

    queens Repository record for Test-Retest Reliability of Decomposition-Based Quantitative Electromyography Derived Motor Unit Number Estimates (opens in a new tab)

  18. Kinetics in Individuals with Unilateral Transtibial Amputations Using Running-Specific Prostheses

    … and anthropometric results indicated that RSP marker placement had little effect on joint kinetic estimations proximal to the prostheses, and trifilar pendulums can measure moments of inertia with <1% error. The running experiments provided the first 3D kinetic descriptions of ILEA running. The …

    maryland Repository record for Kinetics in Individuals with Unilateral Transtibial Amputations Using Running-Specific Prostheses (opens in a new tab)

  19. The Effects of Obesity on Resultant Knee Joint Loads for Gait and Cycling

    … soft tissue artifact, and experimental errors in marker placement. Future studies should correct these limitations and find knee joint contact force rather than knee resultant loads using v EMG-driven experiments. In conclusion, cycling loads were lower than gait loads for NW and OB subjects …

    calpoly Repository record for The Effects of Obesity on Resultant Knee Joint Loads for Gait and Cycling (opens in a new tab)

  20. Validation and standardisation of a two dimensional motion analysis technique to measure normal conformation and gait in Arabian horses.

    … horses. Providing stance of the horse, marker placement and velocity are closely regulated, baseline data can be obtained on one occasion. The standardised method previously validated was used to define normal gait for Arabian horses. Conformation and stride characteristics were assessed …

    cent-lancashire Download PDF for Validation and standardisation of a two dimensional motion analysis technique to measure normal conformation and gait in Arabian horses. (opens in a new tab)

Page 1 of 2