Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"Marx bank"”.

  1. Experimental Study of X-ray Production and Implosion Dynamics of Low-, Mid-, and High-Atomic-Number Materials on University-Scale Z-pinch Machines of Various Architecture

    … loads imploded on the high-impedance UNR Zebra Marx bank generator showed them to be excellent radiators of x-rays. This work focuses heavily on implosions of DPWA loads of low- to mid- to high-atomic-number metals and low-atomic-number DPFL loads performed using the low-impedance UM MAIZE …

    unr Repository record for Experimental Study of X-ray Production and Implosion Dynamics of Low-, Mid-, and High-Atomic-Number Materials on University-Scale Z-pinch Machines of Various Architecture (opens in a new tab)

  2. Laser triggered spark gap using fiber optic transmission

    … which is pulse charged by a three stage Marx bank. Typical operating parameters for the spark gap are: 2 cm gap, 2700 Torr pressure, Ar-N^ gas mixture, and a charging voltage of 200 kV. The single strand, 1 mm, quartz, optical fiber is selected specifically for high power transmission …

    ttu Repository record for Laser triggered spark gap using fiber optic transmission (opens in a new tab)

  3. Optical interferometry with detector system to measure perturbations in plastics

    … of a 540 kV (maximum), 4.54 kJ (maximum) Marx Bank in series with a 50 ns pulse forming Blumlein activated by a self breaking water switch. The energy released by the water dielectric Blumlein is guided by a water-filled coaxial line to a vacuum chamber containing a parallel plate diode. A …

    unlv Repository record for Optical interferometry with detector system to measure perturbations in plastics (opens in a new tab) Download PDF for Optical interferometry with detector system to measure perturbations in plastics (opens in a new tab)

  4. Study of gas density profile about a plastic test piece under vacuum

    … a 540KV, 7O, 50ns, pulsed power device based on Marx Bank and Blumlein technologies. When this machine fires, the energy is funneled to a plastic insulator supported by two circular electrodes. The purpose is to study the surface breakdown properties of the plastic. It is hypothesized that a thin …

    unlv Repository record for Study of gas density profile about a plastic test piece under vacuum (opens in a new tab) Download PDF for Study of gas density profile about a plastic test piece under vacuum (opens in a new tab)

  5. High power solid state modulator for plasma ion implementation

    … A plurality of modulators can be stacked in a Marx geometry to allow complete voltage (implantation energy) scalability. Unlike a classic Marx modulator, the design employs actively controlled charging and discharging paths. This allows maximum modulation flexibility and efficiency. A hybrid …

    sask Repository record for High power solid state modulator for plasma ion implementation (opens in a new tab)

  6. A Numerical Circuit Simulation Study of High Voltage, Multi-Pulse Transmission Lines and Spark Gap Switches

    … of up to four water lines in series charged by a Marx bank of total capacitance and voltage of 39nF and -600kV, respectively, to produce multiple 120ns, -300kV pulses on a matched resistive load of 5.5 . There is a need for a predictive model of SPLITS which encapsulates the reflections due to …

    unm Repository record for A Numerical Circuit Simulation Study of High Voltage, Multi-Pulse Transmission Lines and Spark Gap Switches (opens in a new tab)

  7. Runtime and jitter of a laser triggered gas switch

    … from the trigger section of a Rimfire switch. A Marx bank consisting of 32, 3.1 uF, capacitors that feeds into a 7 nF intermediate storage capacitor drives the switch into a 4 [omega] resistive load. The test switch was pressurized with SF6 and operated near 1 MV. A 30 mJ, 266 nm, Nd:YAG laser …

    missouri Repository record for Runtime and jitter of a laser triggered gas switch (opens in a new tab)

  8. Investigation of the interaction of high current relativistic electron beams with electromagnetic fields

    … modes of a resonant cavity is reported. A Marx bank generator was used to excite a hollow cylindrical cathode stalk producing diode currents of the order of 1 kA. A fraction (? 5%) of the diode current was transmitted through a thin anode mesh to produce a relativistic electron beam …

    strathclyde Repository record for Investigation of the interaction of high current relativistic electron beams with electromagnetic fields (opens in a new tab)

  9. Synergistic Effect of Subnanosecond Pulsed Electric Fields and Temperature on the Viability of Biological Cells

    … The pulse generator used was an 8 stage Marx bank in which the output pulse was formed with a peaking and tailcut switch. The peaking switch was used to decrease the risetime of the output pulse to less than 200 ps, and the tailcut switch was used to cut off the decaying portion of the …

    odu Repository record for Synergistic Effect of Subnanosecond Pulsed Electric Fields and Temperature on the Viability of Biological Cells (opens in a new tab)

  10. Magnetically insulated transmission line oscillator

    … a pulse forming line (PFL) charged by a compact Marx bank capable of producing a high voltage pulse of over 500 kV with a 50 ns duration with less than a 20 ns rise time. The MILO design aimed to meet design criteria set out by the project's sponsor, the Office of Naval Research (ONR). These …

    ttu Repository record for Magnetically insulated transmission line oscillator (opens in a new tab)

  11. Studies of transient intermediates

    … lamp was of a four electrode pair design, with Marx - Bank circuitry, operating at 1000 J with a 1/e decay time of < 4 μs. The photolysis products were analysed by gas chromatography. Experiments were largely limited to studies of ketene with inert gases, hydrogen, and methane, and the mixed …

    oxford Repository record for Studies of transient intermediates (opens in a new tab)

  12. Experimental aspects of plasma wakefields driven in the linear regime

    … a capacitor discharge circuit to the Compact Marx Bank system. This achieved a reduction in electrical noise but also delivered a driving current pulse which was better matched to the plasma channel and so had less current bounce. The circuit delivered a guiding window of around 200 ns and …

    oxford Repository record for Experimental aspects of plasma wakefields driven in the linear regime (opens in a new tab)