Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 42 for “"Marx generator"”
-
Compact, repetitive Marx generator and HPM generation with the Vircator
… compact, 500 kV, 500 J, 10 Hz repetition rate, Marx generator for driving a high power microwave (HPM) source are described. This includes a relevant background discussion of Marx generators and HPM sources, with an emphasis on HPM generation with the virtual cathode oscillator (Vircator). The …
-
Capacitor evaluation for and design of a compact Marx Generator
… construction of a high energy density compact Marx generator are included in this documentation. Characteristics such as decreasing capacitance, decreasing efficiency and increasing energy density are described. Data are taken from eight capacitors, six of which are composed of varying …
-
Compact, Repetitive Marx Generator and HPM Generation with the Vircator
Recent research efforts at Texas Tech University on impulse antenna phased array have shown that an ideal jitter of a small fraction of the rise-time is required to accurately synchronize the array to steer and preserve the rise-time of the radiated pulse. This has necessitated the need to develop …
-
INVESTIGATION AND DESIGN OF IMPULSE RADIATING ANTENNAS DRIVEN WITH MARX GENERATOR
… obtained by driving an antenna with an impulse generator. A Marx generator is preferred and built to generate impulses. Output signal from the Marx generator, whose rise time is slow to feed antenna, is passed through a pulse forming line (PFL) to obtain a suitable signal for antenna feeding. A …
-
Development and Test of Pulse-Forming Network Marx Generator for High-Power Microwave Applications
… Texas Tech University is focused on developing a Marx generator with integrated pulse forming networks (PFNs) capable of satisfying this requirement. A comparison of candidate PFN topologies and the experimental characterization of a Rayleigh PFN is reported. Based on these initial experimental …
-
The Development of a 1 MV 40 kJ Marx Generator and Pulse Forming Line System
… the design and testing of a 1 MV output Marx generator test bed to be used for large scale laser triggered gas switches. The 9-stage bipolar Marx generator is derived from a Marx generator module originating from the decommissioned RITS Accelerator. The Marx generator is housed in an …
-
A fast, 3 MV Marx generator for megavolt oil switch testing and integrated Abramyan network design
… of enhanced and uniform gaps. The 3 megavolt Marx generator is operational with switch configurations tested including large electrode gap spacings with point-ball electrodes. The test results from these experiments will be reported along with a conceptual design for a simple modification …
-
Development of an Experimental Setup for Electron Beam Driven X-Band High-Power Microwave Generation
… driven by a 19-stage pulse-forming network (PFN) Marx generator capable of delivering over 1 MV open-circuit voltage. The Marx generator is used to drive electron emission and microwave generation in a vacuum. Two SCO geometries—a coaxial SCO (CSCO) and a rectangular SCO (RSCO)—were tested, with …
-
C4F7N and Mixtures as SF6 Replacements: Breakdown and Impact
… high voltage excitation delivered to the gap via Marx generator. Volumetric breakdown and gaseous surface flashover datasets are obtained and compared. Results indicate pure C4F7N has a higher voltage hold off than SF6, and a 50% mixture of C4F7N in CO2 performs similarly to SF6 under pulsed …
-
An ultra-fast switch technology concept for future beam transfer at CERN using impact ionization triggering of high voltage thyristors
… im Kickermagneten verdoppelt wird. Die Impulsgeneratoren, die derzeit diese Kickermagneten antreiben, basieren auf Impulsformungsleitungen oder Impulsformungsnetzwerken und Thyratron-Schaltern. Aufgrund der Obsoleszenz der verwendeten Thyratron-Schalter müssen diese Impulsgeneratoren jedoch in …
-
Voltage Measurement Using Slab-Coupled Optical Sensors with Polarization-Maintaining and Absorption-Reduction Fiber
… across the spark gaps at different stages of a Marx generator setup .
-
A detailed study of streamer chambers
… dielectric capacitor and has been charged by a Marx generator, is discussed in detail. The performance of the system is examined and its characteristics are investigated particularly where they are relevant to its use as a particle detector. A statistical model has been programmed and is used to …
-
Pulse Sharpening Circuit for Explosive Emission Cathode Driver
… to reduce the rise-time of a 4-stage Type-E PFN Marx Generator that will be used to study operational characteristics of velvet cathodes. Simulations of the peaking circuit show a reduction in voltage rise-time from over 100 ns to roughly 20 ns. Experimental results taken at 150 kV load voltage …
-
Determination of impulse generator setup for transient testing of power transformers using optimization-enabled electromagnetic transient simulation
… against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor settings of a Marx generator for impulse testing of power transformers. This approach enables us to overcome most of the …
-
CMOS Short Pulse Generator IC Development
… and characterize a Novel CMOS-based short pulse generator (SPG) that can generate a sub-nano second pulse width and capable of repetition while consuming less power. The CMOS Short Pulse Generator will be based on the Marx Generator topology but will use a combination of CMOS switches for fast …
Page 1 of 3