Development of Lambda Factors for Masonry Design with Lightweight Grout
… is still not permitted for use in reinforced masonry construction by the TMS 402/602-16 code. In order to realize the benefits of lightweight grout in U.S. reinforced masonry construction, a codified procedure for its use is required which must be informed by experimental testing. This …
-
Analytical and Experimental Studies to Support Codification of Lightweight Grout for Masonry Design
… (LW) aggregates have many potential benefits in masonry construction including minimizing mass, improving thermal performance, and reducing the potential for shrinkage cracking via internal curing. The current masonry design standard, TMS 402/602-22, permits lightweight aggregate in the …
-
Seismic Design Manual for Interlocking Compressed Earth Blocks
Seismic Design Manual for Interlocking Compressed Earth Blocks Nicholas Edwards Kennedy This thesis presents a comprehensive seismic design manual to be used to design and construct simple Interlocking Compressed Earth Block (ICEB) structures in seismically active regions. ICEBs are earth blocks …
-
Seismic Performance Assessment of Ductile Reinforced Concrete Block Structural Walls
Reinforced masonry (RM) has been gaining a wide acceptance in the low- and mid-rise construction market as an economic and durable structural system. However, challenges still exist in the area of seismic design because of the poor performance of unreinforced masonry during recent earthquake events …
-
Behaviour of Partially Grouted Reinforced Masonry Shear Walls under Cyclic Reversed Loading
… requirements specified in the current Canadian masonry design standard (CSA S304.1 2004) and the provision for unreinforced masonry limits engineers to use the same minimum requirements for regions with low or moderate seismic demands. As a result, this restricts the use of reinforced masonry …
-
High-Strength Reinforcing Bars (HSRB) and TMS 402: A First Study on Grade 80 (550 MPa) Bars
… However, code adoption of HSRBs has lagged in masonry design, which is attributed to the absence of relevant analytical and experimental data. Currently, TMS 402/602 defines the maximum allowable design stress for reinforcing bars at 60,000 psi. This research presents the first study on using …
-
seismic performance of reinforced masonry shear walls with different masonry boundary element configurations
Reinforced masonry (RM) shear walls are commonly used as a seismic force-resisting system (SFRS) in low and mid-rise buildings. Considerable progress has been made on the seismic performance of reinforced masonry shear walls with masonry boundary elements (RMSW+BEs). The integration of masonry …
-
Investigation of Out-of-Plane Properties of Interlocking Compressed Earth Block Walls
… presents results from an experimental program designed to explore the behavior of ICEB walls, built according to current design practice in Indonesia and Thailand, and subjected to out-of-plane loading. A total of five reinforced and grouted ICEB walls were constructed and tested. Results from …
-
Non-linear structural analysis of shear connected cavity walls subject to wind load
… The cavity wall investigated in this study is a masonry assembly comprising two wythes separated by a continuous cavity and tied together, via non-conventional metal connectors. Since the introduction of the new Block Shear$\sp{\rm TM}$ Connector the role and the structural behaviour of …
-
Experimental and analytical studies of reinforced masonry shear walls with and without boundary elements subjected to in-plane cyclic loading
In Canada, reinforced masonry shear walls (RMSWs) can be used as the primary seismic force resisting system (SFRS) in mid to high-rise buildings. In moderate to high seismic regions, the performance of a SFRS is primarily defined by its ability to maintain its strength capacity at large drift …
-
Behaviour and design of slender masonry walls at full- and half-scale subject to axial eccentric loads
The behaviour of slender concrete masonry walls is poorly understood. This is particularly evident by the treatment of such walls in the Canadian masonry design standard, CSA S304-14. Many researchers have noted the poor accuracy of CSA S304-14’s provisions and the need for more experimental data. …
-
Capacity Quantification of Two-Way Arching Reinforced Masonry Walls under Blast Loads
… of nine, one-third scale, arching, reinforced masonry (RM) walls subjected to blast loads and three, one-third scale arching, RM walls subjected to out-of-plane static airbag loads. These RM walls were supported on four sides to enforce two-way arching allowing the ability to monitor individual …
-
Experimental and numerical investigations of ductile slender reinforced masonry shear walls subjected to in-plane seismic loads
Ductile slender reinforced masonry shear walls (DSRMSWs), defined here as ductile walls with height-to-thickness (hu/tw) ratios greater than 20 and height-to-length (hu/Lw) ratios greater than 1.5, that are designed and detailed with modern seismic design provisions are often used as the …
-
Out-of-plane stability of reinforced masonry shear walls under seismic loading : cyclic uniaxial tests
… recent years, widespread application of low-rise masonry construction, including post-disaster buildings like fire halls, has become limited in seismic regions of Canada. This is because the Canadian Masonry Design Standard (CSA S304.1-04) [Canadian Standard Association 2004] mandates stringent …
-
Secondary Moment Effects on Slender Reinforced Masonry Walls
Slender masonry walls can be an effective loadbearing component of buildings that require high ceilings such as warehouses and gymnasiums. This type of construction is also efficient in terms of material usage and over-all construction costs. The proven long-term durability of existing masonry …
-
Seismic Performance Assessment of Reinforced Masonry Core Walls with Boundary Elements
Reinforced masonry shear walls with boundary elements (RMSW+BEs) have emerged as a reliable seismic force-resisting system (SFRS) under the Canadian Standards for the Design of Masonry Structures (CSA S304-14) and the National Building Code of Canada for 2015 (NBCC 2015). While reinforced concrete …
-
Out-of-plane stability of reinforced masonry shear walls under seismic loading : in-plane reversed cyclic testing
Reinforced concrete block masonry shear walls (RMSWs) often constitute the principal seismic force resisting system in masonry structures in Canada. During an earthquake, these walls experience the combined effects of axial gravity loading and overturning moments due to inplane lateral seismic …
-
Behaviour of Reduced-Scale Fully Grouted Concrete Block Masonry Building
… research on shear wall elements in reinforced masonry has been performed on shear walls in isolation. These elements have typically been removed from their structural system and artificial idealized loading is placed on them. Testing is limited to these types of experiments because of …
-
An assessment of the interactions between maritime built heritage and the marine wildlife it supports
… maritime structures with a traditional block-masonry design (e.g. historic seawalls, harbours, breakwaters, etc.) are valued as heritage assets and for the functional benefits they provide coastal communities. Due to their age and traditional construction, stone-built heritage assets may also …