Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Masonry prisms"”.
-
Experimental Investigation on the Shear Strength of Masonry Prisms
Masonry structures are used ubiquitisly all over the world from many years ago till today. However, there are still lots of unknowns in terms of their behavior. These ambiguities become even more significant when the structure is exposed to the shear loads. In addition, the Canadian masonry …
-
Impact of Unit Web Height on the Structural Performance of Concrete Masonry Prisms
… shear stress between the face shells of concrete masonry units (CMUs) and provide structural stability. Any changes to their geometry (i.e., their height and/or thickness) might therefore impact the structural performance of masonry members. While CAN/CSA S304-14 stipulates minimum web thickness …
-
Strength of Concrete Masonry Prisms Constructed with Non-Traditional Grout and Type-M Mortar
The Concrete Masonry Association of California and Nevada in conjunction with Brigham Young University devised a masonry prism testing scheme to aid in the determination of whether prisms constructed with grouts possessing high levels of supplemental cementitious materials could meet minimum …
-
Non-Destructive Means of Predicting Masonry Prism Strength Using Ultrasonic Pulse Velocity (UPV)
Current ASTM standards call for grouted masonry prisms to be tested for compressive strength at 28-days to ensure compliance with the structural design. In the event of failing tests, the subject samples may require redesign or reconstruction which can pose problems due to ongoing development …
-
Compressive and flexural performance of masonry strengthened with eco-friendly ductile cementitious composites (EDCC)
The behaviour of masonry prisms and beams strengthened with eco-friendly ductile cementitious composite (EDCC), which is a form of engineered cementitious composite (ECC), was investigated in this thesis. Compression and out-of-plane bending tests were performed to measure compressive resistance, …
-
Development of a bond-based peridynamic model for masonry structures
Masonry is a popular construction material that has many desirable properties including ease of construction, durability, and fire resistance. However, numerical modeling of masonry prisms and structures with hollow masonry units, such as hollow concrete blocks, remains a challenge due to a …
-
Bond Strength Measurements from an Australian Standard Bond Wrench and ASTM E518 Bond Wrench
… under different loading conditions for masonry walls and columns. Bond testing is a fairly recent addition to the masonry designer’s tool box, with the dominant test over the last 150 years being the compression test. Several methods have been developed to test the masonry bond, with the …
-
Application of Experimentally Calibrated Numerical Models for Prediction of Composite Masonry Prism Strength
The composite masonry prism test is a common laboratory test to determine the compressive strength of a set of masonry prisms (f’mt) to verify that the composite masonry prism assembly, and more importantly, the constituent materials, are providing adequate strength. While constructing masonry …
-
Material Characterisation of New Zealand's Clay Brick Unreinforced Masonry Buildings
… New Zealand's heritage clay brick unreinforced masonry (URM) buildings. The primary focus of this doctoral investigation was to establish a methodology to determine the material properties of existing New Zealand URM buildings. Although researchers from Europe, USA, India and Australia have …
-
Parametric Study on Multi-Story, Partially Grouted, Perforated, Masonry Shear Walls by Finite Element Analysis
… partially grouted, perforated (openings), masonry shear walls using a finite element software FormWorks. The parameters studied were: the strength of grouted masonry prisms f'm,grouted; the strength of un-grouted (hollow) masonry prisms f'm,ungrouted; the ratio of mortar shear strength to …
-
Assessment of the Structural and Thermal Behavior of Concrete Masonry Construction via Experimentally Informed Numerical Models
… behavior and failure patterns of mortarless masonry prisms and walls through experimental tests and numerical models. In addition, the thermal performance of various masonry units is investigated through detailed thermo-fluid dynamic models to contribute to the masonry construction knowledge …
-
Monotonic and Cyclic Behaviour of Reinforced Concrete-Masonry Shear Wall Boundary Elements
… force-resisting system (SFRS), reinforced masonry shear walls with masonry boundary elements (RMSW+BEs) were found to achieve enhanced strength, stability, and ductility levels compared to rectangular RMSWs. The seismic design of RMSW+BEs necessitates reliable experimental and analytical …
-
Effect of nanoparticles on the properties of masonry mortars and assemblages at a cold temperature
Cold weather masonry construction is a major concern for contractors as they either have to implement heating practices for laying and curing masonry systems or postpone the construction to warmer periods. This can lead to loss of productivity rate and delays in construction schedules with …
-
Non-destructive Strength Gain Monitoring of Young Masonry Mortars and Assemblage at Different Ambient Temperatures by Using Dielectric Sensing Technique
The strength development of young masonry mortar and prism is studied through measuring the electrical properties of hydrating mortar by using TWIN-tape capacitance sensor. The dielectric properties over the frequency range of 10 kHz to10 MHz varies during hydration of mortar, providing a means for …
-
Mechanical behaviour of masonry assemblages built with mortar containing anti-freeze admixtures subject to sub-freezing curing temperatures
Cold weather masonry construction is a major concern for contractors in North America as well as other geographic locations. When exposed to cold conditions during construction and curing, the performance of masonry assemblies may be affected. Because of the vulnerability of mortar joints to …
-
Re-evaluation of Acceptance Testing Criteria for Structural Masonry Using the Prism Test Method
The current acceptance criteria for structural masonry in accordance with International Building Code allows for the prism test method to be used. However, without a proper understanding of the effects of variable material properties such as individual masonry unit compressive strength and the …
-
Caracterização das propriedades elétricas e da eficiência de blindagem de argamassas com vermiculita expandida na faixa de micro-ondas
… properties of the walls that constitute the masonry systems of such structures. This study aims to experimentally evaluate the shielding effect of lightweight cement-based mortar coatings, with a volumetric mix ratio of 1:3 (cement), in which sand was progressively replaced by expanded …
-
Development and assessment of a refined concrete masonry system
Masonry, though one of the oldest forms of construction, is still not a perfect system, nor can it ever be. It can only be continuously improved, as has been done over centuries. The effort presented here is an attempt to improve the masonry industry, specifically concrete masonry. It first …
-
Short and Long Term Capacities of Slender Concrete Block Walls
… long term capacities of slender concrete block masonry walls subject to eccentric axial loads were investigated. A finite element model was developed to include both the geometric and the material nonlinearities. To analyze large members, a combined macro-micro finite element model for the …
Page 1 of 2