Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 48 for “"Masonry unit"”
-
Interlocking concrete masonry unit geometry design
… process for interlocking CMU (concrete masonry unit) blocks can help build low-cost homes quickly and efficiently. Wall construction costs are reduced because skilled masons are not needed to build the wall. Instead, unskilled homeowners and laborers can stack the interlocking blocks, …
-
Experimental evaluation and modeling of concrete masonry unit walls
… To develop blast design guidelines for Concrete Masonry Unit (CMU) wall systems, it is necessary to develop analytical models for the static resistance function of these walls that are verified using the results of full-scale physical experiments. The existing analytical models currently used for …
-
Seismic Design of Interlocking Concrete Masonry Unit Block Wall Thesis
… block system is intended to allow communities to create structurally sound buildings at lower costs due to reduced need for skilled masons. By being able to interlock the Concrete Masonry Unit (CMU) blocks, no mortar is required to connect the blocks. Integrity of the wall is ensured by …
-
Application of Low-Portland Cement Content Binders for Potential High-Strength Concrete Masonry Unit Manufacturing
High-strength concrete block masonry units (CMUs) are used in the construction of tall masonry walls in many residential and commercial buildings. As the demand for such blocks is growing, there is an increasing need for high-strength CMUs with lower carbon footprints. Replacing high contents of …
-
(re)presentation
… One such familiar product, the concrete masonry unit, is often ignored and is therefore powerless to encourage much questioning or discovery. The concrete masonry unit is re-presented in a project for a small, movie-palace adjacent to the Masonic Temple in Cincinnati.
-
Re-evaluation of Acceptance Testing Criteria for Structural Masonry Using the Prism Test Method
The current acceptance criteria for structural masonry in accordance with International Building Code allows for the prism test method to be used. However, without a proper understanding of the effects of variable material properties such as individual masonry unit compressive strength and the …
-
Toward Rational Design of Masonry Mortars
Bonding of cement based materials to masonry units substrates is an important aspect of masonry construction and repair of concrete structures. A good bond is necessary for strength and to prevent the infiltration of water between the mortar and the unit. The bond between mortar and masonry unit is …
-
Investigation of Anchorage Performance for Improving Seismic Resilience Against Life-Safety Hazards of Masonry Buildings
Observation of failures of unreinforced masonry buildings during seismic events, retrofitted to resist out-of-plane forces, indicates failure often occurs at anchorages. Particularly for chemical anchors, there is also apparent under-performance compared to design expectation. This thesis presents …
-
The Hygrothermal Performance of Cold Climate Basement Walls Retrofitted with Insulation and a Water Separation Plane
… the hygrothermal performance of hollow concrete masonry unit basement walls in cold climates retrofitted with insulation and a water separation plane. Four full-scale wall systems were constructed and instrumented for the research. Wall and soil hygrothermal data was collected in addition to the …
-
Exploring forms of masonry vaults built without centering
… well as practices in designing and constructing masonry vaults, the thesis explores different forms that can be built without centering during construction. This thesis examines the literature associated with the geometries, construction techniques and methods used to generate masonry arches, …
-
Recalibration of the Unit Strength Method for Determining the Compressive Strength of Grouted Concrete Masonry
… is now several decades old, the current Canadian masonry design standard, CSA S304.1-04, prescribes values for masonry design compressive strength based on the compressive strength of the concrete masonry unit and the type of mortar used in construction. The quality of unit production, masonry …
-
The development of a hollow concrete masonry system for use with near-surface mounted reinforcement
… and structural systems; however reinforced masonry systems have gone virtually unchanged over the last decades. The innovative Surface-Reinforced Concrete Masonry Unit (SRCMU) system makes use of Near-Surface Mounted reinforcement to form a structurally efficient system. Preliminary analysis …
-
Compressive and flexural performance of masonry strengthened with eco-friendly ductile cementitious composites (EDCC)
The behaviour of masonry prisms and beams strengthened with eco-friendly ductile cementitious composite (EDCC), which is a form of engineered cementitious composite (ECC), was investigated in this thesis. Compression and out-of-plane bending tests were performed to measure compressive resistance, …
-
Design Of A 1 Story Building For Mixtlan, Mexico Specially Used By The Elderly Residents
… facility that would be made out of concrete masonry unit, steel beams, and steel columns which will support a metal deck roof. The project's main goal was to maximize the land space by providing an efficient, and spacious building for the elderly. The building will consist of shared bedrooms, …
-
BEYOND CONVENTIONAL CONSTRUCTION A SUSTAINABILITY ASSESSMENT OF 3D-PRINTED CONCRETE FOR MULTI-FAMILY HOUSING
… by comparing it with conventional concrete masonry unit (CMU) construction. A comparative, performance-based methodology was developed using two equivalent wall assemblies evaluated across four key metrics: thermal performance, labor productivity, embodied carbon, and mechanical, electrical, …
-
DESIGN AND SIMULATION OF A DYNAMIC PCM INTEGRATED TROMBE WALL SYSTEM FOR ENSURING THERMAL COMFORT IN HIGHLY GLAZED BUILDINGS
… “Trombe Wall” which consists generally of a masonry unit located at the façades, covered with a glass layer, and collects heat energy from the sun due to a black coating at the exterior side of the wall. However, it has some drawbacks: e.g., Trombe Wall is static, heavy, hard to integrate …
-
Cataloging Built Heritage: Methods of Recording Unit Masonry for the Future of Historic Preservation
… of practitioners on projects, specifically for unit masonry restoration. Recording a historic site is not static over time and should incorporate annotations of change. The standards in recording are not always suitable for the restoration contract and the project team is pressed to create their …
-
Πειραματική και αναλυτική διερεύνηση της συμπεριφοράς διεπιφανειών υδραυλικών ενεμάτων υψηλής διεισδυτικότητας και λίθινων ή πλίνθινων υπόβαθρων
… the bond mechanism of interfaces between masonry units and medium or low mechanical properties hydraulic grouts is experimentally investigated. Based on an extended systematic study, which comprises a) microstructural study of the interfaces b) mechanical tests and c) correlation of the …
Page 1 of 3