Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 645 for “"Mass Flux"”

  1. SHALLOW CUMULUS AND THE MASS-FLUX FRAMEWORK

    … for parameterizing shallow convection via the mass-flux method begins to break down as the underlying assumptions of quasi-equilibrium and small cloud area fraction begin to become violated. Future representations of shallow cumulus may rely heavily on the physics of individual clouds, and this …

    ku Repository record for SHALLOW CUMULUS AND THE MASS-FLUX FRAMEWORK (opens in a new tab)

  2. Evaporation Mass Flux: A Predictive Model and Experiments

    … these properties in a wide range of evaporation mass fluxes, we cast a predictive model of evaporation based on non-equilibrium thermodynamics with no fitting parameters. In this model, only the interfacial temperature of liquid and vapor phases along with vapor pressure are needed to predict …

    houston Repository record for Evaporation Mass Flux: A Predictive Model and Experiments (opens in a new tab)

  3. The Mass Flux of Non-renewable Energy for Humanity

    The global energy supply relies on non-renewable energy sources, coal, crude oil, and natural gas, along with nuclear power from uranium and these finite resources are located within the upper few kilometers of the Earth’s crust. The total quantity of non-renewable energy resources consumed …

    arkansas Repository record for The Mass Flux of Non-renewable Energy for Humanity (opens in a new tab)

  4. Characterizing Vertical Mass Flux Profiles in Aeolian Saltation Systems

    … characteristics of the vertical distributions of mass flux observed in field and laboratory experiments. Thirty vertical mass flux profiles were measured during a field experiment in Jericoacoara, Brazil from October to November, 2008. These data were supplemented with 621 profiles gathered from …

    tamu Repository record for Characterizing Vertical Mass Flux Profiles in Aeolian Saltation Systems (opens in a new tab)

  5. Natural convective heat transfer for vertical cylinders with transverse mass flux.

    This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …

    mcgill Repository record for Natural convective heat transfer for vertical cylinders with transverse mass flux. (opens in a new tab)

  6. Characterization of droplet flight path and mass flux in droplet-based manufacturing

    Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1994.

    mit Repository record for Characterization of droplet flight path and mass flux in droplet-based manufacturing (opens in a new tab)

  7. CHARACTERIZATION OF ZERO MASS FLUX FLOW CONTROL FOR LOW SPEED AIRFOIL SEPARATION CONTROL

    An adaptive wing, a zero mass ux ow control device for low speed airfoil separation control, is investigated both experimentally and computationally at low speeds. The adaptive mechanism in the wings provides variable camber that can be actuated across a range of frequencies and amplitudes. …

    uky-thes Repository record for CHARACTERIZATION OF ZERO MASS FLUX FLOW CONTROL FOR LOW SPEED AIRFOIL SEPARATION CONTROL (opens in a new tab)

  8. Evaluation of two-phase evaporation pressure drop correlations for low refrigerant mass flux.

    … systems. Experimental data was taken at mass fluxes under 70 kg/m2s for two refrigerants, R134A and R600A, internal diameters of aluminum evaporators ranging from 0.186 to 0.317 inches, U-bend internal radii ranging from 0.342 to 0.750 inches in horizontal and vertical orientations of …

    louisville Repository record for Evaluation of two-phase evaporation pressure drop correlations for low refrigerant mass flux. (opens in a new tab)

  9. Dissolution and mass flux from trichloroethene- and toluene- hexadecane multicomponent nonaqueous phase liquid (NAPL) mixtures

    … experiments when compared to TCE:HEX systems. Mass flux reduction analysis shows that the 0.5:0.5:, 0.2:0.8, and 0.1:0.9 mole fractions of both TCE and TOL behave similarly while the 0.05:0.95 mole fractions of TCE and TOL behave the most nonideally and exhibit mass flux reduction before any …

    alabama Repository record for Dissolution and mass flux from trichloroethene- and toluene- hexadecane multicomponent nonaqueous phase liquid (NAPL) mixtures (opens in a new tab)

  10. Pressure gradient modeling during subcooled boiling in high heat-flux and high mass flux systems

    … Advanced Neutron Source reactor that the drift-flux model developed by Avdeev [1982-1988] be used to predict the local pressure gradient. This reactor has fuel cooling channels with a 1.27 mm gap, 80 mm span, and 0.507 m length. The average heat flux is 6 MW/m<sup>2</sup>, the channel inlet …

    ut-knoxville Repository record for Pressure gradient modeling during subcooled boiling in high heat-flux and high mass flux systems (opens in a new tab)

  11. The unification of mass flux and higher-order closure in the simulation of boundary layer turbulence

    … I present a method to combine the concepts of mass-flux closure (MFC) and "standard" higher-order closure (HOC) into one unified theory which is consistent with both formulations. The model that I will describe combines the two approaches in such a manner that the MFC equations are term-by-term …

    colostate Repository record for The unification of mass flux and higher-order closure in the simulation of boundary layer turbulence (opens in a new tab)

  12. Effects of Urban Tree Planting on Pollutant Deposition Mass Flux: The Case of New York City

    … model suggests that the pollutant deposition mass flux is nonlinearly correlated with the tree canopy cover area and increases with the tree canopy cover area until it reaches a critical point. The critical point is when the tree canopy cover area reaches around 90\% of the neighborhood area …

    cornell Repository record for Effects of Urban Tree Planting on Pollutant Deposition Mass Flux: The Case of New York City (opens in a new tab)

  13. Development of a Tunable Diode Laser Absorption Spectroscopy Mass-Flux Sensor for Quantifying Hydrocarbon Storage Tank Venting

    … of an intrinsically safe, low velocity mass-flux sensor for monitoring storage tank venting. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation targeting oxygen within the tank vent line. Similar sensors have been successfully used to …

    carleton Repository record for Development of a Tunable Diode Laser Absorption Spectroscopy Mass-Flux Sensor for Quantifying Hydrocarbon Storage Tank Venting (opens in a new tab)

  14. Observations of shallow trade-wind cumulus cloudiness and mass flux variability and their relationship to boundary layer structure

    … verticale des cumulus océaniques et de leur flux de persiste. Par chance, les capteurs à distance modernes basés sur des iles, plus précisément le radar de nuage vertical de la Barbade possède la sensibilité pour étudier les hydrométéores qui, quand ils sont assez petits, peuvent aussi être …

    mcgill Repository record for Observations of shallow trade-wind cumulus cloudiness and mass flux variability and their relationship to boundary layer structure (opens in a new tab)

  15. Determination of the velocity, density, mass flux and enthalpy profiles for very high temperature arc jet nozzle flow

    Hypervelocity flows for velocities is excess of 1.4 km/sec (Mach 5) require very high stagnation temperature to avoid liquefaction. The arc heater wind tunnel has been designed to provide such flows. The electric-are driven wind tunnel can develop stagnation temperatures up to 13,000 K which will …

    nps Repository record for Determination of the velocity, density, mass flux and enthalpy profiles for very high temperature arc jet nozzle flow (opens in a new tab)

  16. Investigation of Mass Flux Reduction as a Function of Source-Zone Mass Removal for Immiscible-Liquid Contaminated Aquifers

    The magnitude of contaminant mass flux reduction associated with a specific amount of contaminant mass removed is a key consideration for evaluating the effectiveness of a source-zone remediation effort. Thus, there is great interest in characterizing, estimating and predicting relationships …

    arizona-thes Repository record for Investigation of Mass Flux Reduction as a Function of Source-Zone Mass Removal for Immiscible-Liquid Contaminated Aquifers (opens in a new tab)

Page 1 of 33