Showing 1 to 20 of 1624 for “"Mass Spectrometer"”.
-
The mass spectrometer
The mass spectrometer has been developed beyond the experimental stage and several large engineering companies offer them in compact, easily operated units of high precision. They are playing an important role in the recent discoveries and scientific advances of biological, medical, and chemical …
-
A 90º Solid Source Mass Spectrometer
… for use in isotopic analysis by means of a mass spectrometer is reported. In particular, the compound copper acetylacetonate has been successfully employed to obtain ion currents corresponding to the copper isotopes. The second portion of this thesis deals with an energy filter method of …
-
Studies With the Deuterium Mass Spectrometer
… was obtained from the American authorities a mass spectrometer specially designed for routine hydrogen isotope analysis. This instrument was assembled and put into operation at McMaster in the summer of 1944. During the course of subsequent work, two other deuterium mass spectrometers were …
-
A mass spectrometer for isotope analysis
Thesis (M.A.)--Boston University, 1949. This item was digitized by the Internet Archive.
-
An on-line computer assisted mass spectrometer
… computer has been designed and built for a mass spectrometer. This system has been conceived with the primary objectives of improving analytical precision and production. Automated mass spectrometer operation allows for the collection of larger quantities of data while decreasing operator …
-
Calibration of a cycloidal ion mass spectrometer
… and calibration of a cycloidal type ion mass spectrometer (CIMS) for analysis of space plasmas. Crossed electric and magnetic fields are used to force incoming ions to execute cycloidal trajectories with a net displacement proportional to the mass per unit charge of the ions. The magnetic …
-
The Tritium Recoil-Ion Mass Spectrometer Experiment
The Tritium Recoil-Ion Mass Spectrometer (TRIMS) experiment measures the branching ratio between bound ($^3$HeT$^+$) and unbound (T$^+$, $^3$He$^+$) ions that are produced by molecular tritium (T$_2$) beta-decay. This measurement will help validate the current molecular final-state theory utilized …
-
Automobile Exhaust Emission Analysis Using a Mass Spectrometer
No abstract prepared.
-
The precise measurement of mass spectrometer ion currents
… with the problems involved in making precise mass spectrometer ion current measurements. A survey of the literature of the past decade shows that until the new type of system discussed in Chapter 3 was presented by R.D. Russell and F. Kollar, remarkably few developments were made in improving …
-
Ion optics of the mass spectrometer ion source
… factor in determining the sensitivity of a mass spectrometer. Vauthier (1955) has shown for a simple source that the transmission efficiency is very low. The present thesis examines the transmission efficiency of a more complex source. The first part of the thesis deals with the ion optical …
-
Microchannel Plates in Mass Spectrometer Instruments for Spacecraft
… composition gives information on the source and mass dependent entry, heating and acceleration mechanisms. However, most ion composition instruments are not able to clearly distinguish between some of the heavy ions involved in these processes, particularly N+ and O+. This thesis aims to test a …
-
MINIATURE MASS SPECTROMETER SYSTEM WITH A SAMPLING PROBE
… thesis focuses on the development of miniature mass spectrometry systems and the sampling probes. Mass spectrometers are usually installed and used in the analytical laboratory. It requires complex sample preparation before the analysis. Use of miniature mass spectrometer enables the chemical …
-
Microengineered mass spectrometer with field emission ionization source
… thesis describes a design for a microengineered mass spectrometer. This mass spectrometer device uses VLSI processing techniques to scale down the dimensions of an existing mass spectrometer and make it portable. It can be manufactured economically and has the potential to be integrated with more …
-
Miniature Ion Optics Towards a Micro Mass Spectrometer
… of miniature ion optics components of a mass spectrometer (MS) with the ultimate goal to lay the foundation for a compact low-power micromachined MS (µMS) for broad-range chemical analysis. Miniaturization of two specific components a) RF ion traps and b) an ion funnel have been …
-
Real-time Feature Detection in Mass Spectrometer Data
… pre-processing of the complex files created by mass spectrometers during proteomics experiments is required before it is possible to gain any insight from them. A typical mass spectrometer run may produce forty thousand scans of data each containing around two thousand data points. If this data …
-
Single-ultrafine-particle mass spectrometer development and application
A single-ultrafine-particle mass spectrometer was constructed and deployed for size-resolved ultrafine aerosol composition measurements during the winter of 2002-2003 in College Station, Texas. Three separate experiments were held between December and March with six week intervals. Almost 128,000 …
-
Analysis of bediasite with a small mass spectrometer
The general theory of the operation of a mass spectrometer is described with particular attention to the second order focusing. The equations wherever applicable are used for a symmetrical type, 90° deflection mass spectrometer with a radius of 4.6 centimeters. Since errors in the magnetic field …