Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"Mass Spectrometery"”
-
Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology
Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established technique in nuclear forensics for the measurement of long-lived and stable radionuclides. However, the measurement of certain nuclides is hindered by isobaric interferences, which often necessitate additional chemical …
-
Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology
Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established technique in nuclear forensics for the measurement of long-lived and stable radionuclides. However, the measurement of certain nuclides is hindered by isobaric interferences, which often necessitate additional chemical …
-
Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology
Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established technique in nuclear forensics for the measurement of long-lived and stable radionuclides. However, the measurement of certain nuclides is hindered by isobaric interferences, which often necessitate additional chemical …
-
Diamond Intracrystalline Stable Isotope Chemical Image Analysis by Time-of-Flight Secondary Ionization Mass Spectrometery
… I evaluate Time-of-Flight Secondary Ionization Mass Spectrometer (ToF-SIMS) as an alternative method for diamond geochemical analyses. ToF-SIMS analysis can perform in cation and anion mode to measure the entire periodic table of an analyte. Establishing a quantitative ToF-SIMS methodology would …
-
U-Pb geochronology of the Acasta Gneiss Complex in Northwest Canada
… using laser ablation inductively coupled plasma mass spectrometery (LA-ICPMS). Twelve of the samples show evidence for two distinct crystallization events, one which formed the cores and another in which the mantle domain overgrew the cores. The oldest cores were dated at >4.0 Ga. This provides …
-
Spectrometric approaches towards onsite sample analysis
… Confirmatory tests, such as gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS), require extensive sample preparation. This process can be time-consuming and less cost-effective. One possible way to address this challenge is by performing an onsite …
-
Structural characterization of water-soluble atmospheric organic matter by ultrahigh-resolution mass spectrometry
… induced dissociation and ultrahigh-resolution mass spectrometry. Tandem mass analysis was performed on scan ranges between 100-400 u to characterize the structures of nitrogen and/or sulfur containing species. CHNO, CHOS, and CHNOS compounds were targeted specifically because of the high number …
-
Traumatic brain injury biomarker discovery using mass spectrometry imaging of 3D neural cultures
… time consuming multi step chromatographic mass spectrometery (MS) techniques or pre-defined serial probing using traditional assays, making the identification of biomarker panels limiting and expensive. These shortfalls have motivated the development of a MS based probe that can be embedded …
-
Quantitative Analysis of Earthy and Musty Odors in Drinking Water Sources Impacted by Wastewater and Algal Derived Contaminants
… water samples. Gas Chromatography coupled with Mass Spectrometery (GC/MS) in full scan mode was used to analyze the compounds adsorbed onto the fiber. The following parameters were optimized in order to enhance extraction efficiency: extraction temperature, extraction time, desorption time, …
-
Controlling the Production of Off-odor Guaiacol by Alicyclobacillus acidoterrestris in Apple juice or a Microbiological Medium
… new analytical instrument Selected Ion Flow Tube Mass Spectrometery (SIFT-MS). Incubated samples were held at 20-45 degree centigrade and pH 2.7-6.7 with 10mg/L vanillin. Minimum inhibitory concentrations (MICs) of polylysine and lauric arginate were determined at 37 degree centigrade and pH 3.7. …
-
Combined Hybrid-Isolation and Cleavage (CHIAC): A novel method for studies of RNA structure
… amenable to the powerful analytical method of mass spectrometery (MS). The novelty of the CHIAC approach is to use a biotinylated DNAzyme as the specific hybridization probe. Following hybridizationand recovery of the RNA:DNA duplexes using paramagnetic streptavidincoated beads all in the …
-
Development of liquid chromatography mass spectrometry methods for the monitoring of ropivacaine, endogenous steroids and dihydroartemisinin
… chromatography coupled with a high resolution mass spectrometery. In this chapter a highly sensitive method for the determination of the free and bound portion of ropivacaine in patients undergoing knee and hip joint surgery was developed. Patient samples were provided by the Golden Jubilee …
-
Exploring novel excited state dynamics using multi-mass ion imaging and universal ionisation
… imaging has been coupled to the Pixel Imaging Mass Spectrometery cam- era to enable cutting edge multi-mass imaging experiments to be performed following pulsed laser excitation of jet-cooled gas phase molecular samples. These experiments exploit different forms of universal ionisation to make …
-
Eco-friendly driven remediation of the indoor air environment: the synthesis of novel transition metal doped titania/silica aerogels for degradation of volatile and semi-volatile organic compounds
… of CO2 was monitored via gas chromatography-mass spectrometery. To increase the activity, visible light was introduced to the system. Experiments have shown that a 10 mol % manganese doped titania/silica system, in the presence of light, can degrade acetaldehyde. The cobalt doped counterpart …
-
Micro-structural and functional properties of TiAlCN/VCN coating produced by High Power Impulse Magnetron Sputtering Technology.
… by plasma sampling using energy-resolved mass spectrometery. During the coating of TiAlCN/VCN, the plasma analysis has confirmed the higher production rate of metal ions and free carbon in case of HIPIMS-UBM in contrast to pure UBM. This has resulted to a denser closed columnar …
-
Chemical Leaching Methods and Measurements of Marine Labile Particulate [Fe] and Δ56Fe
… by high-resolution inductively coupled plasma-mass spectrometery (ICP-MS) and varied from 1mg/g to 35mg/g, with longer treatment times, stronger acids, and hotter temperatures generally associated with an increase in leached Fe. δ56Fe in these leachates were determined by Neptune, …
-
In vitro investigation of putative interactions between the RING finger domain of Retinoblastoma Binding Protein 6 (RBBP6) and various substrates
… the sample of UbcH1 was subsequently found using mass spectrometery to be partially degraded. GST-tagged RBBP6 RING was able to precipitate MDM2 from HeLa lysate. This extends previous reports that full length RBBP6 and MDM2 interact directly and play a role in the suppression of p53 during …
-
A genetic screen to isolate “Lariat” peptide inhibitors of protein function
… the lactone bond with heavy water, followed by mass spectrometry analysis showed that ~ 44% of purified lariat contained an intact lactone bond. To improve the stability of the lactone bond, we introduced mutations into the engineered intein and analyzed their processing and stability by mass …
-
Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS) in an Aquatic Ecosystem - Distribution and Fate
… coupled to electrospray ionisation tandem mass spectrometery (HLPC-ESI-MS). Due to the possibility of ionisation suppression, isotope dilution or standard addition method was applied. Analysis of waste waters collected from four different waste water treatment plants (WWTPs) located in …
Page 1 of 2