  1. A vibrating-reed mass-flow-meter.

    For many fluid-mass-rate-of -f low metering situations, a measure of the fluid's density-velocity product is required. The density -velocity (pv) product is multiplied by an effective conduit cross -sectional area to yield the mass-rate-of-f low. The area multiplication is accomplished by simply …

    nps Repository record for A vibrating-reed mass-flow-meter. (opens in a new tab)

  2. The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter

    … such as pressure sensors and accelerometers. MEMS flow sensing has emerged as a field of interest in microfluidics, with a variety of sensing methods being miniaturized, such as thermal anemometry, ultrasonic sensing and flow measurement based on the Coriolis effect. Coriolis sensing …

    njit Repository record for The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter (opens in a new tab)

  3. Bunkerproblematik med avseende på flödesmätning

    … thesis is about the bunker problems regarding flow measurement. Bunker problems mainly consist of quantity- and quality problems. The authors have limited this thesis to the quantity problems which got the authors attention during vocational training. These problems may be due to measurement …

    chalmers Repository record for Bunkerproblematik med avseende på flödesmätning (opens in a new tab)

  4. Mass Flow Measurement of Gaseous Breathing Air Through the Liquid Air Pack Respirator

    … life indicator for this type of respirator. Flow meters were evaluated as alternatives to the timer. The objective of the evaluations was to determine if a mass flow meter could accurately measure the breathing air consumed during use of the respirator. Two laboratory tests of a …

    ucf Repository record for Mass Flow Measurement of Gaseous Breathing Air Through the Liquid Air Pack Respirator (opens in a new tab)

  5. An improved determination of calibration gas corrections for a typical thermal mass flowmeter design

    <p>The mass flow controller, or MFC, is a thermal flow device used extensively for the measurement and control of hazardous and corrosive process gases in the semiconductor industry. Calibration of the mass flow meter is conventionally performed using benign, non-hazardous surrogate gases, such as …

    ut-knoxville Repository record for An improved determination of calibration gas corrections for a typical thermal mass flowmeter design (opens in a new tab)

  6. Can mass flow meters solve the problem with discrepancies in bunker deliveries?

    … have made its way in to the market, the Coriolis Mass Flow Meter. This flow meter measures the mass directly, instead of volume and is more difficult to tamper with. The method used for this study was a qualitative method with semi-structured interviews. The selected respondents are actors within …

    chalmers Repository record for Can mass flow meters solve the problem with discrepancies in bunker deliveries? (opens in a new tab)

  7. Evaluation and visualization of refrigerant two-phase flow in distributor

    This study aims at understanding flow distribution exiting thermostatic expansion valve and through distributor. It is well known that when two-phase flow goes through separation devices such as distributors and headers, mal-distribution is unavoidable due to different properties of liquid and …

    uiuc Repository record for Evaluation and visualization of refrigerant two-phase flow in distributor (opens in a new tab)

  8. Trace Validation of Blowdown Transients Performed in the McMaster CHF Test Facility

    … of intermittent dryout in vertical annular flow was done using TRAC/RELAP Advanced Computational Engine (TRACE) to validate two phase conductive and convective heat transfer, and critical flow correlations. The TRACE model is based on experiments done by Statham & Novog and include the …

    mcmaster Repository record for Trace Validation of Blowdown Transients Performed in the McMaster CHF Test Facility (opens in a new tab)

  9. Refrigerant charge reduction in small commercial refrigeration systems

    … each of them, as well as pressure transducers, a mass flow meter, and thermocouples. Charge optimization and charge distribution experiments were conducted. The condenser is found to be the component that retains the most charge. The system was modeled using Engineering Equation Solver (EES) for …

    uiuc Repository record for Refrigerant charge reduction in small commercial refrigeration systems (opens in a new tab)

  10. Optimisation of commercial production processes for polyester resins

    … aim of the scheme was to examine the process parameters involved in commercial polyester production and recommend new procedures to ensure both consistent process operations and product quality. The specific reactions involved in the preparation of polyester resins are discussed along with …

    aston Repository record for Optimisation of commercial production processes for polyester resins (opens in a new tab) Download PDF for Optimisation of commercial production processes for polyester resins (opens in a new tab)

  11. Parameter Estimation of Dynamic Air-conditioning Component Models Using Limited Sensor Data

    … an approach for identifying critical model parameters in dynamic air-conditioning systems using limited sensor information. The expansion valve model and the compressor model parameters play a crucial role in the system model's accuracy. In the past, these parameters have been estimated using a …

    tamu Repository record for Parameter Estimation of Dynamic Air-conditioning Component Models Using Limited Sensor Data (opens in a new tab)

  12. Design And Performance Evaluation Of An Integrated Miniature Single Stage Centrifugal Compressor And Permanent Magnet Synchronous Motor

    … and tested with air as the working fluid at mass flow rate of 7.3 grams per sec, with a compression ratio of 1.58 and driven by a 2 KW permanent magnet synchronous motor at a design speed of 108,000 rpm. A permanent magnet synchronous motor rotor was designed to operate to operate over …

    ucf Repository record for Design And Performance Evaluation Of An Integrated Miniature Single Stage Centrifugal Compressor And Permanent Magnet Synchronous Motor (opens in a new tab)

  13. Flow Characterization and Redesign of Load-Leveling Valves for Improving Transient Dynamics of Heavy Truck Air Suspensions

    This research provides a thorough flow characterization study to compare the functionality of two types of load-leveling valves that are commonly used for air suspension systems of commercial trucks. The first valve features a simple disk/slot design and is relatively compact for installation. The …

    vt Repository record for Flow Characterization and Redesign of Load-Leveling Valves for Improving Transient Dynamics of Heavy Truck Air Suspensions (opens in a new tab)

  14. Numerical and Experimental Analysis of an Elastohydrodynamic Seal for Gases

    … while sustaining a continuous sCO2 film. a 2" diameter shaft static test rig was designed at Georgia Southern University before the actual dynamic testing at Sandia National Laboratories for proof-of-concept purposes. For simplicity, the working fluid was chosen to be Nitrogen, and the tests were …

    gsu Repository record for Numerical and Experimental Analysis of an Elastohydrodynamic Seal for Gases (opens in a new tab)

  15. Long duration measurements of pneumatic controller emissions on onshore natural gas gathering stations

    … Gathering Emission Factor (GEF) study. A thermal mass flow meter based emission measurement system was developed to perform direct measurements of pneumatic controller emissions over multiday periods. This measurement system was developed based on methods used in previous studies, with design …

    colostate Repository record for Long duration measurements of pneumatic controller emissions on onshore natural gas gathering stations (opens in a new tab)

  16. Phase/amplitude estimation for tuning and monitoring

    … applying them to the transmitter of a Coriolis mass-flow meter. Schemes are devised for the tracking and control of the second mode of measurementtube oscillation alongside the so-called 'driven mode', at which the tubes are usually vibrated, leading to useful information being made available …

    oxford Restricted access

  17. Návrh průtokového měřiče paliva

    Bakalářská práce se zabývá konstrukčním návrhem průtokového měřiče paliva pro použití na čerpacích stanicích. V úvodu práce je řešena problematika měření průtoku. Obsahuje stručný přehled průtokoměrů různých typů. Podrobněji je popsán princip Coriolisova průtokoměru. V konstrukční části je …

    brno-tech Repository record for Návrh průtokového měřiče paliva (opens in a new tab)

  18. Optimisation of tomato paste production, storage and use : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Biotechnology & Bioprocess Engineering at Massey University

    … an inaccurate reading when employing the refractometer °Brix method. To solve this, the tomato paste must be centrifuged in order to separate the insoluble from soluble portion within the tomato paste. Colour, acidity and microbial stability are also important quality characteristics of tomato …

    massey Repository record for Optimisation of tomato paste production, storage and use : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Biotechnology & Bioprocess Engineering at Massey University (opens in a new tab)

  19. Investigation of a Four-Intersecting-Vane Rotary Expander in a Vapour Compression Refrigeration System

    … in static and dynamic conditions. The main parameters studied were volumetric efficiency, isentropic efficiency and output power. Dynamic tests were carried out to study the effects of different grades of lubrication on the performance of the expander at various operating conditions. The maximum …

    auckland-ms Repository record for Investigation of a Four-Intersecting-Vane Rotary Expander in a Vapour Compression Refrigeration System (opens in a new tab)