Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 284 for “"Mass measurements"”
-
Metrological Developments for Aerosol and Mass Measurements
… already established fields of metrology, such as mass, and in new evolving fields, such as aerosol particles, where the traceability is incomplete. In this thesis, a novel device called single charged aerosol reference (SCAR) invented by Tampere University of Technology (TUT) was developed into a …
-
Mass Measurements of Neon Isotopes at The-Trap
… ist ein Penningfallen Experiment zur Präzisionsmassenbestimmung am Max-Planck- Institut für Kernphysik in Heidelberg, Deutschland. Für das Datenerfassungssystem wurden ein neues Python-Program und eine neue PHP-Website entwickelt. Unter Verwendung eines Lock-In Amplifiers wurde ein neues …
-
First mass measurements with the MPIK/UW-PTMS
The precise determination of the 3H-3He mass ratio, and hence the tritium Q-value, is of relevance for the measurement of the electron anti-neutrino mass performed by the Karlsruhe Tritium Neutrino experiment (KATRIN). By determining this ratio to an uncertainty of better than 1 part in 10^10 , …
-
Direct mass measurements beyond the proton drip-line
… the velocity filter SHIP. First high-precision measurements were performed determining the masses of 18 neutron-deficient isotopes in the terbium-to-thulium region with relative uncertainties of about 10-8. The masses of nine nuclides were measured for the first time. Four of them (144Ho, 145Ho, …
-
High precision mass measurements near N=Z=33
Thesis (Ph. D.)--Michigan State University. Department of Physics, 2007
-
Direct Mass Measurements and Global Evaluation of Atomic Masses
L’évaluation des masses atomiques (Ame), commencée dans les années 1960, est la source la plus fiable d’informations complètes sur les masses atomiques. Elle fournit les meilleures valeurs pour les masses atomiques et les incertitudes associées en évaluant les données expérimentales de …
-
Investigating the astrophysical rp-process through atomic mass measurements
The Canadian Penning Trap (CPT) mass spectrometer at the Argonne National Laboratory makes precise mass measurements of both stable and unstable nuclides. To date, more than 60 radioactive isotopes having half-lives as short as one second have been measured with the CPT with a mass precision …
-
Molecular Effects in Tritium Beta-Decay Neutrino-Mass Measurements
… distribution is crucial to extracting a neutrino mass from molecular tritium-based experiments including the upcoming Karlsruhe Tritium Neutrino Mass Experiment. This dissertation studies molecular systematics for the upcoming neutrino mass measurements and discusses the measurement of molecular …
-
Precision mass measurements for studies of nucleosynthesis via the rapid neutron-capture process : penning-trap mass measurements of neutron-rich cadmium and caesium isotopes
… the experimental work done for the precision mass measurements of neutron-rich cadmium (129−131 Cd) and caesium (132,146−148 Cs) isotopes. Measurements were done at the on-line radioactive ion-beam facility ISOLDE by using the four-trap mass spectrometer ISOLTRAP. The cadmium isotopes are key …
-
Single-cell mass measurements for drug susceptibility testing in cancer
… resonator (SMR) is a sensor that measures the mass of individual micron-scale particles by detecting a shift in resonance frequency as particles flow through a hollow resonating micro-cantilever beam. While SMRs offer extreme precision for measuring mass, their applications have been limited by …
-
Precision Mass Measurements at THe-Trap and the FSU trap
THe-Trap is a Penning-trap mass spectrometer at the Max-Planck-Institute for Nuclear Physics in Heidelberg, Germany, that aims to measure the T/3He mass ratio with a relative uncertainty of 10^(−11). Improvements of the measurement technique, in particular the measurement of systematic shifts, …
-
Direct mass measurements on exotic nuclei with SHIPTRAP and ISOLTRAP
Direkte Massenmessungen an exotischen Kernen mit SHIPTRAP und ISOLTRAP - Mit dem Penningfallenspektrometer ISOLTRAP am on-line Separator ISOLDE/CERN wurden direkte Massenmessungen an exotischen Xenonkernen im Massenbereich zwischen 114 bis 124 durchgeführt. Die Massen der Isotope 114-116 Xe konnten …
-
Terra hunting: extreme precision mass-measurements of Earth like worlds
… activity in order to mitigate its effects on RV measurements and help push detection thresholds towards low-mass/long-period exoplanets such as Earth-analogues.<br/><br/>I first outline the exoplanet discovery process by presenting the discovery of three hot Jupiters by NGTS, as well as updating …
-
Ion and plasma systematics during the first KATRIN neutrino mass measurements
… is targeted to determine the effective mass of the electron antineutrino with an unprecedented sensitivity of 200$\,$meV/$c^2$ (90\% C.L.). This will be achieved by measuring the beta-spectrum of tritium close to the kinematic endpoint at 18.6$\,$keV. Gaseous tritium is contained in the …
-
PENTATRAP: A novel Penning-trap system for high-precision mass measurements
The novel Penning-trap mass spectrometer PENTATRAP aims at mass-ratio determinations of medium-heavy to heavy ions with relative uncertainties below 10^−11. From the mass ratios of certain ion species, the corresponding mass differences will be determined with sub-eV/c^2 uncertainties. These mass …
-
Penning trap mass measurements to test three-body forces in atomic nuclei
… pressure since the advent of precision mass measurements is the isobaric multiplet mass equation, in which the binding energies of states in an isobaric multiplet should vary quadratically with the z-projection of the isospin. This is a consequence of the isospin dependent component of …
-
Red supergiant counterparts of ULXs : paving the way to dynamical mass measurements
Radboud Universiteit Nijmegen, 09 december 2015
Page 1 of 15