Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Material Measurement"”
-
Analysis and Design of a Fluidic-Reconfigurable Substrate Integrated Waveguide Resonator
… post of fluidic dispersions with variable material properties embedded in a two inductive post static SIW resonator defines the tuning mechanism. The development of an analytical closed-form expression for the resonant frequency and Q across reconfiguration, a circuit model, and full-wave …
-
A Small-Perturbation Automatic-Differentiation (SPAD) Method for Evaluating Uncertainty in Computational Electromagnetics
… to the required specifications;results of material measurement systems have errors and uncertainty; and the frequency of operation and angles of observation will not be perfect inmeasurement systems. In spite of this, virtually all CEM algorithms presume asingle deterministic solution …
-
Measurements Of Spin Torques Generated By Topological Insulators And Heavy Metals
This dissertation discusses measurements of spin torques generated by two classes of materials; heavy metals and topological insulators. In the first half, we use spin torque ferromagnetic resonance with and without the addition of DC currents to measure spin torques generated by the topological …
-
Design Of A Material Test Kit For Use From 1.6 Ghz To 26.5 Ghz And Its Use In Evaluation Of Dielectric Properties Of Foam Core Materials Used In Sandwich Composites
In the present world, the usage of composite materials has been considerably increased in various fields. The composites have found a wide variety of applications in the field of electrical engineering and electronics such as insulators, electromagnetic interference (EMI) shielding materials etc. …
-
Autonomous Aerial Localization of Radioactive Point Sources via Recursive Bayesian Estimation and Contour Analysis
… to autonomously investigate radioactive material using an unmanned aerial vehicle. Performing this autonomous analysis comprises five major steps: ingress from a base of operations to the danger zone, initial detection of radioactive material, measurement of the strength of radioactive …
-
Implementation of Ultrafast Optical Characterization Techniques
… pulse energy lasers to be used. In the past such measurements have been made primarily with high energy low repetition rate lasers such as Q-switched or modelocked and Q-switched Nd3+:YAG lasers and its harmonics or Nd3+:YAG pumped dye lasers. Such dye lasers while tunable are difficult to use and …
-
Medžiagų atpažinimas terahercine spektroskopija /
… radiation is safe for human health. Also many materials are transparent in terahertz frequency range. That is why terahertz wavelengths are widely used in spectroscopy. One of the most popular terahertz spectroscopic techniques is the terahertz time-domain spectroscopy. It can reveal the …
-
Tan B :
… occurrence, methods for thiaminase I activity measurement are needed. A radiometric assay was developed and has been dominant for nearly 30 years. However this assay is only available to laboratories equipped for radioactive material measurement and it is very expensive. Another assay is the …
-
Acoustical properties of polymeric fibres and their characterisation
… were made from a range of polymers and their material properties varied considerably. This work enabled us to develop a better understanding of the applicability of various empirical and theoretical models for the prediction of acoustical and non-acoustical properties of polymeric fibres. It …
-
Highly sensitive resonance-based planar sensors for nondestructive complex material characterization
… evaluation in a variety of applications, such as material characterization, structural health monitoring, microfluidics identification, agricultural, and biomedical sensing. Resonance-based microwave planar sensors have demonstrated multiple advantages, including simple fabrication, low-cost, …
-
Laser-based spectroscopy and spectrometry
… were extensively investigated in nanoscience, materials science, biomedical science, and etc. Different lasers with wavelengths from ultraviolet to infrared, and with duration from continuous-wave (CW) to femtoseconds have been employed in various spectroscopic techniques to investigate the …
-
Fabrication and Characterization of Surface Grating DFB Lasers Using AlGaAs/GaAs Quantum Well Material
… DFB lasers, using AlGaAs/GaAs quantum well material, and also demonstrate its potential for integration. The operation of this surface grating DFB laser combines both lateral optical confinement and distributed feedback provided by gratings etched along the side of the laser stripe in the …
-
Precision measurement of attenuation and phase-shift at microwave and millimeter-wave frequencies
We have developed novel microwave attenuation measurement systems using heterodyne receivers at 0.05−26.5 GHz. The leakage, noise floor and DR of the system have been analysed. The receiver noise floor is around −172 dBm, with a record high DR of ~186.7 dB at 26 GHz. A microwave phase-shift …
-
Uncertainty in inverse elasticity problems
… of elastic inverse problems: Given one or more measurements of the displacement field within an elastic material, determine the material property distribution within the material. This thesis is focused on uncertainty quantification in inverse problem solutions, with application to inverse …
-
High-Sensitivity Microwave Sensors for Material, Displacement and Rotation Measurement With Environmental Compensation
… half-mode SIW sensor is presented for real-time measurement of displacement and permittivity of samples under test (SUT), offering high sensitivity while compensating for environmental factors such as temperature. With this design, temperature-induced variations can be eliminated without …
-
Ultra-wideband, On-Chip Phased Arrays for Millimeter-wave and Terahertz Applications
… mobile communications. Utilization of low-loss materials in such designs can address the substrate coupling issues and improve the radiation efficiency. Moreover, the structural support and packaging materials that exhibit low loss are indispensable for cost-effective realization of integrated …
-
Radio Frequency Characterization and Modelling of Low Temperature Co-Fired Ceramic (LTCC) Material and Devices
… components accurately. Investigating various measurement techniques, we decided to use a parallel plate capacitor for the characterization of a LTCC substrate from 100 MHz to 1 GHz and a conductor backed coplanar waveguide from 1 GHz to 10 GHz. After fabrication of several test structures on …
-
High resolution nano-patterning using roller type soft mold UV nanoimprint lithography
… suitable for both rigid and flexible substrate material. The process is based on roller type ultraviolet nanoimprint lithography (UV-RNIL). By using UV-curable polymer resist, room temperature and low pressure nano-patterning process was achieved. The application of flexible soft molds in the …
-
Digital twin and AI enabled predictive maintenance in building industry
… innovative Six M methodology—Machine, Manpower, Material, Measurement, Milieu, and Method. This approach emphasises the entire building lifecycle, enabling stakeholders to optimise operations, resource allocation, and decision-making across multiple facets of building management. The 6M …
-
Měření permitivity materiálů v mikrovlnném pásmu – laboratorní úloha
Tato práce se zabývá vypracováním laboratorní úlohy se zaměřením na měření permitivity materiálů v mikrovlnném pásmu. Pro vlastní měření jsou použity dvě vlnovodové metody. První metoda využívá pro určení parametrů bezeztrátových materiálů zkrácení vlnové délky v materiálu. Druhá metoda využívá pro …