Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Maximum Intensity Projection"”.

  1. RAPID 3D TRACING OF THE MOUSE BRAIN NEUROVASCULATURE WITH LOCAL MAXIMUM INTENSITY PROJECTION AND MOVING WINDOWS

    … tracing, I have designed a method based on local maximum intensity projection (MIP). MIP can utilize any existing 2D tracing algorithms for use in 3D tracing. It can also significantly reduce the search space. However, most neurovascular data are too complex to directly use MIP on a large scale. …

    tamu Repository record for RAPID 3D TRACING OF THE MOUSE BRAIN NEUROVASCULATURE WITH LOCAL MAXIMUM INTENSITY PROJECTION AND MOVING WINDOWS (opens in a new tab)

  2. Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed to mography Image Sets For Stereotactic Body Radiation Therapy

    … can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to define the volume that encompasses the motion envelope of the moving gross target volume (GTV). Because of the close relationship that exists between the MIP and the …

    uthsc Repository record for Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed to mography Image Sets For Stereotactic Body Radiation Therapy (opens in a new tab)

  3. Development of a non-invasive imaging technique for characterizing subchondral bone density and stiffness

    … this novel imaging technique with an existing maximum intensity projection technique, 3) determine the ex vivo and in vivo precision of proximal tibial subchondral bone density measures using this novel imaging technique, and 4) determine whether this novel imaging technique can be used to …

    ubc Repository record for Development of a non-invasive imaging technique for characterizing subchondral bone density and stiffness (opens in a new tab) Download PDF for Development of a non-invasive imaging technique for characterizing subchondral bone density and stiffness (opens in a new tab)

  4. Method of visualisation influences accuracy of measurements in cone-beam computed tomography

    … rendering, multiplanar reformatting (MPR), maximum intensity projection of the volume of interest (VOIMIP), and average intensity projection of the volume of interest (VOIAvIP). All radiological methods were tested for repeatability and compared with anatomical results for accuracy, and …

    zurich Restricted access

  5. Automatic Seedpoint Selection and Tracing of Microstructures in the Knife-Edge Scanning Microscope Mouse Brain Data Set

    … I traced the neuronal structures using a local maximum intensity projection method that employs moving windows. The contributions of this work include reducing time required for setting seedpoints, decreasing the number of falsely detected somata, and improving 3D neuronal reconstruction and …

    tamu Repository record for Automatic Seedpoint Selection and Tracing of Microstructures in the Knife-Edge Scanning Microscope Mouse Brain Data Set (opens in a new tab)

  6. Distinguishing Calliphorid Puparia Through Application of Confocal Laser Scanning Microscopy

    … of specimens. The data generated from the maximum intensity projection images was then used for multivariate discriminate analysis to test for characters useful in delimiting taxa. This provides a basis for puparia identification regardless of image methodology.

    nebraska Repository record for Distinguishing Calliphorid Puparia Through Application of Confocal Laser Scanning Microscopy (opens in a new tab)

  7. Ο ρόλος της αξονικής αγγειογραφίας στην διερεύνηση της αυτόματης υπαραχνοειδούς αιμορραγίας

    … tools, namely multiplanar reformation, maximum intensity projection, shaded surface displayvirtual endoscopy and direct volume rendering. Materials and Methods: We prospectively studied a group of 205 patients with spontaneous subarachnoid haemorrhage. One hundred ninety eight (198) …

    greece Repository record for Ο ρόλος της αξονικής αγγειογραφίας στην διερεύνηση της αυτόματης υπαραχνοειδούς αιμορραγίας (opens in a new tab)

  8. Moving Phantom Study of Stereotactic Body Radiation Therapy for Lung Cancer

    … of the irregular target motion in the maximum intensity projection (MIP) images generated from 4DCT, which could not be corrected by CBCT. A method of Extended Distance Virtual Isocenter (EDVI) was developed to lower the toxicity of healthy tissues. In all, caution should be used when …

    utswmed Repository record for Moving Phantom Study of Stereotactic Body Radiation Therapy for Lung Cancer (opens in a new tab)

  9. Analyzing Heterogeneity in Cell Images Using Machine Learning

    … by projecting them on a single plane using maximum intensity projection and using conventional algorithms that were developed for monolayer cultures resulting in the loss of information from the third dimension. To overcome the limitations, I have developed a novel 3D segmentation free image …

    toronto-retro Repository record for Analyzing Heterogeneity in Cell Images Using Machine Learning (opens in a new tab)

  10. Investigation into the use of Four Dimensional Cone Beam Computed Tomography for Internal Target Volume definition in Lung Stereotactic Ablative Body Radiation

    … cells and healthy tissue. Due to the high dose intensity required, precision is crucial, particularly for tumours located in the torso, which houses vital organs such as the heart and lungs. Movement of lung tumours during breathing complicates their precise localisation. Hence, targeting the …

    adelaide Repository record for Investigation into the use of Four Dimensional Cone Beam Computed Tomography for Internal Target Volume definition in Lung Stereotactic Ablative Body Radiation (opens in a new tab)

  11. An End-to-End Multi-Modal Deep Learning Framework for Transparent and Interpretable AI-assisted Neuroimaging

    … processing entire volume, 2D ConvNet measuring maximum intensity projection signatures, and graph neural network encoding lesion spatial relation- ships) are unified using equal-projection fusion to combine their embeddings, solving train loss degeneration towards stream dominance that occurred …

    unt Repository record for An End-to-End Multi-Modal Deep Learning Framework for Transparent and Interpretable AI-assisted Neuroimaging (opens in a new tab)

  12. Semi-automated Cell Annotation Framework Using Deep Learning

    … z-stacks. Using 2D methods for labeling on the Maximum Intensity Projection(MIP) of the z-stacks would lead to undercounting due to the possibility of overlapping cells in the z-plane (masking) \cite{palakmimounet}. To address this issue, the present study proposes an innovative solution – a …

    usf Repository record for Semi-automated Cell Annotation Framework Using Deep Learning (opens in a new tab)

  13. Einfluss der dorsalen Stabilisierung auf angrenzende und transfixierte Facettengelenke bei Patienten mit thorakolumbalen Wirbelsäulenverletzungen

    … der subchondralen Knochenlamelle, die im „Maximum-Intensity-Projection-Algorithmus“ ebenfalls dreidimensional rekonstruiert und mit Falschfarben belegt wurde. Die durch Übereinanderprojektion der Datensätze gewonnenen Densitogramme dienten als Basis zur Bestimmung von Änderungen des …

    lmu-germany Repository record for Einfluss der dorsalen Stabilisierung auf angrenzende und transfixierte Facettengelenke bei Patienten mit thorakolumbalen Wirbelsäulenverletzungen (opens in a new tab)

  14. On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy

    … to the 10 phase benchmark, followed by the Maximum Intensity Projection (MIP) approach, then Average Intensity Projection (AIP), and finally FB. For PTV structures based on the delineation of the single phase FB image set, we have shown even with 10 mm superior-inferior margin [5 mm axial] …

    buffalo Repository record for On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy (opens in a new tab)

  15. The prostatic tumour stroma

    … structures, a conventionally applied 2D method (Maximum Intensity Projection for 3D reconstructed images, MIP) was compared to an optimised 3D analysing tool. As a result, it was discovered that MIP analysis did not allow for an accurate determination of 3D endothelial network parameters, and can …

    qucosa-diss

  16. Optimization strategies for respiratory motion management in stereotactic body radiation therapy

    … workflow of cycle-based sorting (CBS) without maximum inspiration detection (and therefore no clear starting point for the individual breathing cycles) seemed to be affected by these potential errors, the usage of CBS with correct maximum detection and another sorting algorithm of the …

    lmu-germany Repository record for Optimization strategies for respiratory motion management in stereotactic body radiation therapy (opens in a new tab)

  17. Program pro zobrazení a práci s objemovými daty

    Práce souhrnně popisuje možnosti zobrazení objemových dat. Blíže se věnuje skalárnímu typu objemových algoritmů, který následně dělí na techniky nepřímého a přímého zobrazení objemových dat. Z nepřímých technik přibližuje metodu Marching Cubes. Přímé techniky dále člení na algoritmy triviální a …

    brno-tech Repository record for Program pro zobrazení a práci s objemovými daty (opens in a new tab)