Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 553 for “"Mcnp"”
-
Electron photon calculations using MCNP
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1998.
-
Using MCNP for fusion neutronics
… Carlo programs, in particular the widely-used MCNP, are the preferred tools for this. The International Fusion Materials Irradiation Facility (IFMIF), intended to test materials in intense neutron fields with a spectrum similar to that prevailing in fusion reactors, also requires neutronics …
-
Simulace stínění ionizujícího záření programem MCNP
… žiarenia získané významným Monte Carlo kódom - MCNP6, porovnané s výsledkami z experimentov, ktoré boli vykonané v Dielni ionizujúceho žiarenia na Ústave elektroenergetiky, FEKT VUT. Tieto experimenty pozostávali z umiestnenia rádioizotopu kobalt-60 v troch rôznych polohách do oloveného …
-
Medical physics calculations with MCNP: a primer
… modeling is the Monte Carlo N-Particle (MCNP) radiation transport code. However, no comprehensive document has been written to introduce the use of the MCNP code for simulating medical physics applications. This document, a primer, addresses this need by leading the medical physics user …
-
MCNP Study of IPNS C Moderator Groove Configuration
Made available in DSpace on 2017-07-06T18:48:57Z (GMT). No. of bitstreams: 3 Keller_Steven_E_MS.pdf: 45536581 bytes, checksum: 66704840c669bb8886ccaa508f6b55c1 (MD5) Keller_Steven_E_MS_ABS.pdf: 536907 bytes, checksum: 5b8888a9a86c06349b79e6a352ffbc14 (MD5) license.txt: 4813 bytes, checksum: …
-
MCNP modeling of prostate brachytherapy and organ dosimetry
Using the computer code Monte Carlo N-Particle (MCNP), doses were calculated for organs of interest such as the large intestine, urinary bladder, testes, and kidneys while patients were undergoing prostate brachytherapy. This research is important because the doses delivered to the prostate are …
-
Variance reduction techniques for MCNP applied to PBMR
… of the Monte Carlo N-Particle code (MCNP) to evaluate reactor shielding applications is greatly improved through the use of variance reduction techniques. This study deals with the analysis of variance reduction methods, more specifically, variance reduction methods applied in MCNP …
-
Multi-Purpose Research Reactor Designs Using MCNP and Origen
Made available in DSpace on 2017-07-06T18:48:39Z (GMT). No. of bitstreams: 3 Hu_Jianwei_MS.pdf: 12941059 bytes, checksum: bab58c978d20c697c63132361864a936 (MD5) Hu_Jianwei_MS_ABS.pdf: 35914 bytes, checksum: e11195f3129796aebd383242e916a02c (MD5) license.txt: 4813 bytes, checksum: …
-
Gamma spectroscopy by artificial neural network coupled with MCNP
… study comes from data library availability on MCNP. A perceptron network was employed to identify five elements from gamma spectra. In quantitative analysis, better results were obtained when the neural fitting tool in MATLAB was used. As a training function, Levenberg-Marquardt algorithm was …
-
MCNP simulations for standoff bomb detection using neutron interrogation
… may not be explosive, were simulated using the MCNP5 code. Both shielding and collimation of 14.1-MeV neutron beams were simulated to produce effective neutron beams for target interrogation purposes and to minimize dose levels. Templates corresponding to particular target scenarios were …
-
Radiation dosimetry and medical physics calculations using MCNP 5
… problems were analyzed using a beta version of MCNP 5 as part of an international intercomparison of radiation dosimetry computer codes, sponsored by the European Commission committee on the quality assurance of computational tools in radiation dosimetry. Results have been submitted to the …
-
MCNP-Based Analysis on Simulating Small Changes in System Responses
<p>Problems often arise that require the use of MCNP to simulate a small response change caused by a variation in system parameters. The direct computation approach for such problems often leads to a too large statistical uncertainty for the predicted response change to be acceptable when the …
-
Automated variance reduction for Monte Carlo shielding analyses with MCNP
… biasing and the weight window technique in MCNP shielding calculations has been developed. The method is based on the approach used in the SAS4 module of the SCALE code system, which derives the biasing parameters from an adjoint one-dimensional Discrete Ordinates calculation. Unlike SAS4 …
-
Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT
… determining the beam intensity profiles. An MCNP simulation is run to score the beam directions; the simulation is run as an adjoint problem to reduce simulation time, with the target as the source and the detectors scoring the dose for the gantry angles of the beam. Then, an optimization …
-
A Patient Specific Treatment Planning Method for BNCT Utilizing MCNP and RayStation
… systems have chosen Monte Carlo N-Particle (MCNP) as their dose engine due to its widespread usage and verified results. Several of the MCNP based treatment planning systems use standard DICOM computed tomography (CT) files to voxelize and create the patient specific model in MCNP. From this …
-
MCODE-3 : time-dependent depletion isotopics with MCNP-5 and SCALE-6.1
… the Monte Carlo N-Particle transport code, MCNP, with the Oak Ridge Isotope Generation point depletion code, ORIGEN-S. MCNP provides reaction rates and neutron flux in user-specified irradiation material regions. COUPLE, a data-editing code included in the SCALE- 6.1 software package, uses …
-
Modeling the wall effects of a tissue equivalent proportional counter using MCNP
… volume. A Monte Carlo transport code, MCNP, is chosen to simulate the transport of secondary electrons, or delta rays, within a TEPC The TEPC modeled in this study is composed of A-150 tissue equivalent plastic and propane-based tissue equivalent gas. The Rudd model is used to describe …
-
Uncertainty Quantification of Fission Product Concentration Estimation in MCNP Fuel Depletion Simulations
Monte Carlo N-Particle Transport Code (MCNP) is a Monte Carlo computational neutron transport code with multi-core parallel simulation functionality developed by Los Alamos National Laboratory and is widely used in nuclear reactor modeling and nuclear fuel burnup/depletion simulations. In burnup …
Page 1 of 28