Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"Measuring blood flow"”.
-
Measuring blood flow and pulsatility with MRI: optimisation, validation and application in cerebral small vessel disease
… disease (SVD) is the breakdown of the small blood vessels of the brain, leading to many cases of stroke and dementia. The pathophysiology of SVD is largely unknown, although several mechanisms have been suggested. One such mechanism is the role of increased blood flow pulsatility into the …
-
A non-invasive method for measuring blood flow rate in superficial veins from a single thermal image.
… is proposed to find an easy way to measure the blood flow using thermal camera to help detecting cots and vascular diseases (Venous disease, Arterial disease). In this thesis, a general framework is proposed to use a thermal image based measurement technique for the volumetric flow rate of a …
-
Quantification of Blood Flow Velocity Using Color Sensing
Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler …
-
Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients
… resistive index, nitrite, nitric oxide, systolic blood pressure, diastolic blood pressure.Objectives: i) To determine the repeatability of ultrasound parameters in measuring blood flow in diabetic patients with early-stage peripheral artery disease (PAD); ii) To determine whether there is a …
-
Ultrasound Reliability of Blood Flow Measurements in Neck Vasculature: A Comparison Between a Novice and Experienced Sonographer
… literature on the reliability of ultrasound in measuring blood flow volume of the neck vasculature remains sparse, especially when comparing the reliability of these measurements taken by a novice sonographer to an experienced sonographer. This study sought to examine the reliability of blood …
-
COMPUTATIONAL ANALYSIS OF VASCULAR ANEURYSMS
… hemodynamics, characterized by swirling flow patterns, can lead to cellular and structural changes that disrupt normal physiological processes and contribute to destructive vascular remodeling. Integrating hemodynamic analysis into clinical assessments of aneurysms has become crucial, …
-
The measurement of choroidal blood flow using krypton-85
… of the methods used previously to measure ocular blood flow. The theory of the Inert gas clearance method for measuring blood flow in homogeneously perfused tissues is discussed, in Chapter 2. A series of experiments designed to measure control values of choroidal blood flow in rabbits using …
-
Evaluation of a Single Injection Radioiodinated Hippuran Technique for the Estimation of Renal Blood Flow in the Dog
… are in general two different methods used for measuring regional blood flows; the direct and the indirect methods. The direct methods either involve the use of direct volume metering devices such as rotameters and droprecorders or are based upon measurement of some alteration in physical …
-
Investigating Mitral Regurgitation using 4D-flow MRI-based Markers and Personalized Experimental Models
… countries. MR is defined as systolic retrograde blood flow from the left ventricle (LV) into the left atrium (LA) and has the most frequent indications for valve surgery. Thus, early detection and assessment are important. Echocardiography (Doppler) is the first-line assessment of MR; however, it …
-
Optical Coherence Tomography for Dermatological Applications
… was initiated. The use of Doppler OCT for measuring blood flow changes has the potential to tailor the treatment individually eventually with an improved outcome. A Doppler OCT system was tested using phantoms and normal skin followed by patient investigations. Addressing the technical …
-
Blood flow measurement in the zebrafish heart using light sheet microscopy
… heart was mostly confined to single projection blood flow measurements or computational fluid dynamics simulations using only the information of the heart wall structure. Hence, techniques capable of direct 3D + time resolved blood flow and heart wall motion are necessary to deepen the …
-
Tracer Measurements of Periodic Flow in a Tube Using Nuclear Magnetic Resonance (NMR) Flowmeter and Its Physiological Application
… been used in many areas of technology. The NMR flowmeter is one of the important applications. The principal components of the NMR flowmeter are the upstream magnetizer and the downstream detector. The liquid is magnetized as it flows through the magnetizer and the level of magnetization is …
-
The role of geometry in the hemodynamics associated with stroke development in sickle cell anemia
Sickle cell anemia (SCA) is a genetic blood disorder which affects over 4 million people globally. Though SCA is caused by a single point mutation in the hemoglobin of red blood cells, this change has devastating affects which can impact the entire human body and reduce life expectancy. Amongst the …
-
The Effects of Passive Hallux Adduction on Posterior Tibial Artery Blood Flow Compared to the Lateral Plantar Artery
… hallux adduction has been shown to decrease blood flow in the lateral plantar artery (LPA) in a non-weight-bearing condition. Further research in weight-bearing and shod conditions is necessary to explore relationships between altered blood flow and injury or tissue healing. However, …
-
Evaluation of Laser Doppler Flowmetry and Transillumination Laser Speckle Contrast Imaging to Measure Blood Flow Change in Ischemia Mouse Hindlimb Models
… buildup and narrowing of the arteries, reduces blood flow to the extremities. Promoting collateral arteriogenesis can help redirect blood flow. However, simple growth of collaterals may not be enough to reverse PAD. Instead, the ability for the collaterals to vasodilate and control blood flow is …
-
Effect of Hemorrhage on Blood Flow to Marrow and Osseous Tissue in Conscious Rabbits
… and to validate a quantitative method for measuring blood flow rates in marrow and bone.Cardiac output and regional blood flow determinations were made using the radioactive microsphere technique. Microspheres (15 u dia) were injected into unanesthetized rabbits via a chronically implanted …
-
An investigation of transit-time flowmetry parameters in coronary artery by-pass grafting
… inspection or palpation of the graft to assess flow can be deceiving, and European guidelines on myocardial revascularization now recommend intraoperative determination of graft flow with Transit time flowmetry (TTFM). Today, TTFM is the most commonly applied technique for intraoperative graft …