Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Mechanical compressions"”
-
Modifying the size of nanopores of alginate microcapsules
… and inducing conformational changes via Mach-1TM mechanical compression. Fluorescence microscopy was used to visualize the diffusion of FITC-dextran weight markers and fluorescent polystyrene nanoparticles into the microcapsules (d = 300 μm) and macrocapsules (d = 3 mm) for all experimental …
-
ASSESSMENT OF EFFICACY OF MANUAL COMPRESSION USING END TIDAL CO2 AND RETURN OF SPONTANEOUS CIRCULATION (ROSC) VS NATIONAL BENCHMARKSFOR INPATIENT CARDIAC ARREST
… during cardiac arrest. Quality chest compressions result in a better likelihood of return of spontaneous circulation, also known as ROSC. (Meaney et al., 2013) Currently, the AHA recommends end tidal C02 (ETC02) monitoring to evaluate the quality of compressions(Bhende, Karasic , & …
-
CEREBRAL BLOOD FLOW DURING CARDIOPULMONARY RESUSCITATION
… and short axis of the left ventricle (LVCC) for mechanical chest compressions (LUCAS III). ETCO2, BP (arterial catheter line), and CBF velocity (CBFv; transcranial Doppler) were measured pre-cardiac arrest, during cardiac arrest, and through three rounds of basic life support (BLS) CPR. Data were …
-
Thoracoabdominal Pressure Coupling During Prone Versus Supine Cardiopulmonary Resuscitation: A Cadaver-Based Mechanistic Study
… experimental studies have shown that prone compressions can generate arterial pressures comparable with, or greater than, those observed during supine CPR. The relative contributions of abdominal and thoracic pressure to these arterial responses remain unresolved. This dissertation examined …
-
Nonlinear macroscopic description of liquid crystalline elastomers in external fields
… coupling of liquid crystalline order and elastic mechanical deformations makes them unique. In particular, we investigate the macroscopic behavior of cholesteric and nematic SCLSCEs in external electric and mechanical fields. We characterize the respective liquid crystalline state using the …
-
The Influence of Timing on the Hemodynamic Effects of Compression Devices and Development of Sensor Driven Timing Mechanisms
… stasis can be prevented by applying active mechanical compressions to the lower limbs, such as with an intermittent pneumatic compression (IPC) device; these devices have been clinically shown to reduce venous stasis and thereby prevent DVT formation. The main objectives of this thesis were …
-
Extraction de composés énergétiques à partir de microalgues par application conjuguée d’impulsions de champ électrique et de sollicitations mécaniques dans un système microfluidique.
… combinée de champs électriques pulsés, et de compressions mécaniques (à travers un système microfluidique dédié) en tant que prétraitements à l’extraction de composés lipidiques, riches en énergie, produits par la microalgue Chlamydomonas reinhardtii, a donc été étudiée. Les mécanismes mis en …