Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 23 for “"Mechanical index"”
-
Ultrasound-mediated transscleral drug delivery
… sclera were done using ultrasound with different mechanical index and frequencies (40 kHz - 1 MHz). The dependence of the enhancement by ultrasound to cavitation type was also examined. Results showed that intrascleral protein penetration increases with mechanical index (MI) in stable cavitation …
-
Acoustic Intensity Measurement System: Application in Localized Drug Delivery
… using power and acoustic intensity measurements. Mechanical index, spatial peak pulse average intensity, and spatial temporal pulse average intensity calculations were made using hydrophone measurements set-up in a tank measurement system. These were compared to safety limits defined by the Food …
-
Progress towards ultrasound-mediated targeted drug delivery in the small intestine
… number, pulse repetition frequency, duty cycle, mechanical index and surface area insonated. A decrease in barrier function was associated with lower frequencies, more cycles, more pulses, a higher duty cycle, a higher mechanical index and insonating a larger surface area. The results obtained …
-
Safety Considerations and Clinical Benefit Analysis for the Use of Elevated Acoustic Output in Diagnostic Ultrasound Imaging
… quantification with the use of elevated Mechanical Index (MI) during ultrasonic harmonic shear wave elasticity imaging (SWEI). Since ultrasound SWEI sequences consist of a long push pulse and a short tracking pulse, it remains unclear which one of the two pulses is impacted more by the …
-
Nonlinear optical imaging study on ultrasound-mediated trans-scleral drug delivery
… and the effect of ultrasound with different mechanical index (MI=0.03, 0.136, 0.2, 0.8) was investigated. To analyze the images, four quantitative methods were developed, and the results showed that the collagen network structure did not shown significant change after ultrasound is applied. …
-
Transthoracic Cardiac Acoustic Radiation Force Impulse Imaging
… of tissue heating, hydrophone intensity and mechanical index (MI) measurements, and thermocouple transducer face heating measurements. For the pulse sequences used in later animal and clinical studies, results from the safety analysis indicates that transthoracic ARFI imaging can be safely …
-
Conoscenza e consapevolezza sugli effetti biologici degli ultrasuoni nella pratica clinica in Italia: risultati di una inchiesta con questionario tra ecografisti della socetà italiana di ultrasonologia in medicina e biologia (S.I.U.M.B.)
… but few of them knew the definition of specific indexes. There was a general knowledge about the safe use of ultrasound in obstetrics, but there was a poor knowledge of biological effects of US: only about 37% answered correctly to questions about damage of vasculature of lung by high Mechanical …
-
High-Frequency Ultrasound Drug Delivery and Cavitation
… A threshold for release between 0.35 and 0.40 in mechanical index was found at 70 kHz and shown to correspond with the appearance of the subharmonic signal in the acoustic spectrum. Additionally, drug release was found to correlate with increase in subharmonic emission. No evidence of drug release …
-
Mechanism of ocular barriers modulation by low-intensity low-frequency ultrasound on sclera and retinal pigment epithelium
… that the application of 40 kHz ultrasound with a mechanical index (MI) = 0.20 could overcome the ocular barriers to deliver macromolecules into the eye. In this thesis, I mainly focus on: 1) exploring the effect of ultrasound on the scleral collagen arrangement and its correlation to the …
-
Low intensity low frequency ultrasound-assisted transcorneal delivery of riboflavin for corneal collagen cross-linking in treating keratoconus
… such as riboflavin concentration, ultrasound mechanical index, dwell-time and ocular surface area exposed were optimized to enhance the corneal permeability to riboflavin. Histological studies were also performed to examine the safety of LILF ultrasound. We optimized that LILF ultrasound at 40 …
-
Morphological effects of pulsed Doppler diagnostic ultrasound on rat adult lung and fetal tissues : a thesis presented in fulfillment of the requirements for the degree of Master of Science in Physiology and Anatomy at Massey University
… Three levels of exposure were represented by a mechanical index (Ml) of 0.5, 0.6 and 1.0. Subpleural multifocal intra-alveolar haemorrhage was found to a significant degree in exposed adult rat lung and less significantly in fetal lung. The threshold for adult lung haemorrhage was considered to …
-
Nonlinear Wave Propagation in High Frequency Ultrasound Imaging
… propagation results and used to calculate the Mechanical Index MI. We propose a slight modification to MI to solve the inconsistencies associated with the coverage of nonlinear effects in MI. A modification is also required in the existing upper limit for the hydrophone calibration bandwidth to …
-
Diagnostik des Vesikoureteralen Reflux : In-vitro-Vergleich eines Ultraschallkontrastmittels der 1. mit einem der 2. Generation
… mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25%, 0,5% und 1%, Levovist in einer Konzentration von 5% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese …
-
Η συμβολή των σκιαστικών ουσιών στην υπερηχογραφική μελέτη του ουροποιητικού συστήματος
… the technic of Contrast Tissue Imaging with low mechanical index. 5. Storage of the study in the hard disc unit of the ultrasound unit for a repeat second look (Images and Video). During our study 42 individuals were examined, specifically 29 men and 13 women. Ageing between 25 years till 78 …
-
Use of VEGFR-2 targeted microbubbles (BR55, Bracco imaging) for the early ultrasound evaluation of response to antiangiogenic treatment in a xenograft model of hepatocarcinoma
… then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated …
-
Theoretical modelling of ultrasound contrast agents
… the behaviour of some contrast agents at low mechanical index (MI) have been successful at higher MI the behaviour of MBs is still not well understood. Understanding and predicting the response ofMBs to medical ultrasound can lead to improvements in the clinical use of MBs through improved …
-
Quantifying the Impact of Imaging with Elevated Acoustic Output in Diagnostic Ultrasound
… and Drug Administration (FDA) guideline for the Mechanical Index (MI < 1.9). This value was derived from historic values, rather than being linked to scientific evidence of bioeffects. A recent report from the American Institute of Ultrasound in Medicine (AIUM) concluded that exceeding the …
-
Temporal SNR Guided Adaptive B-mode and Color Doppler Transmit Parameter Selection
… levels. Acoustic output can be described by the Mechanical Index (MI), which is based on the pulse pressure, or Thermal Index (TI), a measure of tissue heating. Following the ALARA (As Low As Reasonably Achievable) principle, acoustic output should be kept as low as possible to minimize any risks …
-
Spatial Coherence-Based Adaptive Acoustic Output Selection for Diagnostic Ultrasound
… imaging through metrics such as intensity, Mechanical Index (MI), and Thermal Index (TI). However, even within these guideline values, if the acoustic exposure levels used do not benefit image quality, they represent an unnecessary risk to patient safety. Ultrasound users have control over …
-
Backscatter Spatial Coherence for Ultrasonic Image Quality Characterization: Theory and Applications
… phantom and liver images formed with varying mechanical index (MI) to assess the feasibility of adaptive acoustic output selection using LOC feedback. Measurements of LOC in simulation and phantom demonstrated lower variability in LOC relative to contrast and CNR over a wide range of …
Page 1 of 2