Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 178 for “"Mechanical test"”

  1. Novel mechanical test methods applied to bulk metallic glasses

    … limited volumes. Therefore, to understand their mechanical behaviour, innovative small scales tests are required. Here aspects of mechanical behaviour covering elastic, time dependent and plastic deformation are explored. For indentation (elastic moduli and hardness measurements), test data …

    whiterose Repository record for Novel mechanical test methods applied to bulk metallic glasses (opens in a new tab)

  2. A Novel Quantitative Mechanical Test of Atherosclerotic Plaque Stability

    … human atherosclerosis, we also applied peeling tests on human Left Anterior Descending (LAD) coronary arteries to investigate interlaminar adhesive strength of vessels. Our results indicate a significant effect of genotype on measured G values for plaques in apoE knockout (KO) and apoE MMP12 …

    south-carolina Repository record for A Novel Quantitative Mechanical Test of Atherosclerotic Plaque Stability (opens in a new tab)

  3. Improvements in digital image correlation and application in material mechanical test

    … implemented and applied to the miniature tensile test. A convenient experimental method to determine the true stress-strain curve is proposed. The instantaneous cross-section area is estimated by only one camera in aid of DIC method. The derived true stress-strain curves and mechanical parameters …

    must-thes Repository record for Improvements in digital image correlation and application in material mechanical test (opens in a new tab)

  4. Design of an electro-mechanical hexapod for accelerated life testing of optical fiber assemblies

    … Degradation (FRD) [3]. Therefore, a life cycle test must be conducted to study fiber behavior and measure FRD as a function of time. This thesis describes the design and design methodology of an electro-mechanical test apparatus for accelerated life testing of optical fiber assemblies. The …

    texas Repository record for Design of an electro-mechanical hexapod for accelerated life testing of optical fiber assemblies (opens in a new tab)

  5. Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components

    … in which primary fixation is obtained through mechanical fixation immediately post-operative and secondary fixation is achieved through bone ingrowth at the bone-implant interface. To promote bone ingrowth, low micromotion between the bone and implant of 20 µm to 50 µm is required. Due to the …

    queens Repository record for Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components (opens in a new tab)

  6. Evaluation of Hot Mix Asphalt moisture sensitivity using the Nottingham Asphalt Test equipment

    … developed into two categories; visual inspection test and mechanical test. However, most of them have been developed in pre-Superpave mix design. This thesis summarizes the new mechanical test for Superpave using the Nottingham Asphalt Test equipment (NAT). The mechanisms of Hot Mix Asphalt (HMA) …

    iastate Repository record for Evaluation of Hot Mix Asphalt moisture sensitivity using the Nottingham Asphalt Test equipment (opens in a new tab)

  7. Exploration of the Additive Manufacturing Process Development Space using High-throughput Mechanical Property Assays

    … be addressed. One such discrepancy is in the mechanical testing of AM samples so they may be optimized, qualified, and certified. This is mainly due to the highly anisotropic nature of AM builds and the costs associated with fabricating and testing mechanical test coupons. To mitigate this …

    gatech Repository record for Exploration of the Additive Manufacturing Process Development Space using High-throughput Mechanical Property Assays (opens in a new tab)

  8. Processing - Structure - Property Relationships in Catalyst Cured Epoxy Systems (Morphology)

    … differential scanning calorimetry (DSC), tensile mechanical test, and transmission electron microscopy (TEM) were employed in the investigation.

    uiuc Repository record for Processing - Structure - Property Relationships in Catalyst Cured Epoxy Systems (Morphology) (opens in a new tab)

  9. Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula

    … of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were …

    brazil-ufrn Repository record for Avaliação mecânica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da região anterior de mandíbula (opens in a new tab)

  10. The Evaluation of Usefulness of the FEA and Relationship Between Trabecular Microstructural and Biomechanical Properties In Human Femoral Head

    … trabecular bone microstructure and its biomechanical properties, the microimage-based FEA and the experimental test were performed in the same bone cores from the primary compressive trabecular system of human femoral head. Twenty-one human femoral heads were obtained from 11 patients …

    ajou Repository record for The Evaluation of Usefulness of the FEA and Relationship Between Trabecular Microstructural and Biomechanical Properties In Human Femoral Head (opens in a new tab) Embargoed until 9999-12-31

  11. Ground reaction force estimation to assess football player movement on hybrid turfs

    … dataset and allowing me to borrow the AA test device for six weeks of testing in Germany. These mechanical test data provided important information for this work. Also thanks to David Rigby and Tom for teaching me how to use the mechanical test devices. Apart from the people directly …

    sheffield-hallam Repository record for Ground reaction force estimation to assess football player movement on hybrid turfs (opens in a new tab)

  12. Collagen Fiber Re-Alignment and Uncrimping in Response to Loading: Determining Structure-Function Relationships Using a Developmental Tendon Mouse Model

    … to load, how this change relates to tendon mechanical properties, and if these changes are dependent on the underlying structure. Throughout postnatal development, dramatic structural and compositional changes occur in tendon. Postnatal tendons, with immature collagen networks, may respond …

    penn Repository record for Collagen Fiber Re-Alignment and Uncrimping in Response to Loading: Determining Structure-Function Relationships Using a Developmental Tendon Mouse Model (opens in a new tab)

  13. Continuous measurement of aging response in aluminum alloys by eddy current methods

    … of such continuous measurements, combined with mechanical test data, will allow one to gain active control of the aging process and hence the material properties of aluminum alloys. The ultimate results would be higher reliability of engineering structures. The increased precision in control of …

    nps Repository record for Continuous measurement of aging response in aluminum alloys by eddy current methods (opens in a new tab)

  14. Mechanical Testing and Material Modelling of Rigid Polyurethane Foam, a Bone Surrogate

    … standard bone surrogate as it mimics the mechanical behaviour of cancellous bone. It is commonly used for the evaluation of medical implants through Finite Element Analysis (FEA) and mechanical testing. The first objective of this study was to outline methods for testing and evaluation of …

    queens Repository record for Mechanical Testing and Material Modelling of Rigid Polyurethane Foam, a Bone Surrogate (opens in a new tab)

  15. STRUCTURAL, MECHANICAL AND VISCOELASTIC CHANGES IN OVARIECTOMIZED RAT UPON DRUG TREATMENT AND VIBRATION THERAPY

    … bone was firstly revealed by BMD, biomarkers and mechanical test. Viscoelasticity of the bones were further examined using nanoindentation and dynamic mechanical analyzer. Combined treatment had better therapeutic effects in terms of increased viscosity and loss tangent. Besides drugs, WBV effect …

    nus Repository record for STRUCTURAL, MECHANICAL AND VISCOELASTIC CHANGES IN OVARIECTOMIZED RAT UPON DRUG TREATMENT AND VIBRATION THERAPY (opens in a new tab)

  16. Interfaces of Mono-Elemental Nanostructures: Edges, Grain Boundaries, and Junctions

    … and its surrounding atmosphere – define the mechanical strength and electronic band structure of the material, as well as provides active sites for chemical reactions and growth. Grain boundaries – the interface separating two grains of the same material – change the geometrical landscape, …

    rice Repository record for Interfaces of Mono-Elemental Nanostructures: Edges, Grain Boundaries, and Junctions (opens in a new tab)

  17. Stress Characterization of Stretchable Crystalline Semiconductors

    … 2D and 3D numerical analyses of the effect of mechanical anisotropy in (100) Si on crystalline stretchable behavior, revealing the <100> direction can be up to 36\% more stretchable than the <110> direction, and (0001) GaN has no anisotropic dependence. (ii.) A micro-fabrication procedure which …

    maryland Repository record for Stress Characterization of Stretchable Crystalline Semiconductors (opens in a new tab)

  18. A comparison of the fracture toughness, hardness, impact strength, and thermal expansion of two dental porcelains

    … this comparative study, a series of mechanical test were performed on both Optec HSP and Ceramco II.</p><p>An indentation technique was used to calculate the hardness and fracture toughness, the Izod method with a 1 ft-lb pendulum was used to obtain the impact strength, and the …

    njit Repository record for A comparison of the fracture toughness, hardness, impact strength, and thermal expansion of two dental porcelains (opens in a new tab)

  19. Development of an injectable gelatin material formulation for cartilage tissue engineering

    … tissue engineering was developed. Since the mechanical properties and degradation of uncross-linked gelatin cannot fulfill the requirements of tissue engineering, five crosslinking methods (UV, Rose Bengal, EDC/NHS, Genipin, Transglutaminase-TG) were screened in terms of their efficacy in …

    ohiolink Repository record for Development of an injectable gelatin material formulation for cartilage tissue engineering (opens in a new tab)

  20. Joining Carbon Fiber and Aluminum with Ultrasonic Additive Manufacturing

    … structures is necessary. Current adhesive and mechanical fastening methods used for joining CFRP to metals are not ideal due to poor mechanical properties and incompatibility with current manufacturing infrastructure. Consequently, new joining techniques are needed for increasing the use of …

    ohiolink Repository record for Joining Carbon Fiber and Aluminum with Ultrasonic Additive Manufacturing (opens in a new tab)

Page 1 of 9