Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Medical Dosimetry"”

  1. MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY

    MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY Dennis Sourvanos Joseph P. Fiorellini Timothy C. Zhu The successful application of Photobiomodulation (PBM) and Photodynamic Therapy (PDT) in clinical settings is challenging due to the complex tissue boundaries and …

    penn Repository record for MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY (opens in a new tab)

  2. Evaluating Assessment and Effectiveness Data to Program Characteristics in Accredited Medical Dosimetry Programs in the United States

    The purpose of this study is to analyze medical dosimetry programs in the United States with regard to their assessment data and specific program characteristics. I identified participating programs through the Joint Review Committee on Education in Radiologic Technology (JRCERT) program directory …

    siu-theses Repository record for Evaluating Assessment and Effectiveness Data to Program Characteristics in Accredited Medical Dosimetry Programs in the United States (opens in a new tab)

  3. An Evaluation of the Medical Dosimetry Program at the University of Texas MD Anderson Cancer Center School of Health Professions.

    … oncology teams, which consist of physicians, medical physicists, and several allied health professionals, such as medical dosimetrists, and radiation therapists, are responsible to design and deliver the proper dose of radiation to the patients. Medical dosimetrists are an integral part of …

    houston Repository record for An Evaluation of the Medical Dosimetry Program at the University of Texas MD Anderson Cancer Center School of Health Professions. (opens in a new tab)

  4. EVALUATING DIFFERENCES IN TEST ACHIEVEMENT OF MEDICAL DOSIMETRY STUDENTS PARTICIPATING IN INSTRUCTION WITH SYNCHRONOUS VERSUS ASYNCHRONOUS VIDEO CONSIDERING PERSONAL LEARNING STYLE AND BLOOM'S TAXONOMY LEVEL

    … was to determine the dominant learning style of dosimetry students. The study also investigated to see if there was a significant difference in test performance based on synchronous/asynchronous participation, specific learning style, and the Bloom's taxonomy level of the test questions. To …

    siu-theses Repository record for EVALUATING DIFFERENCES IN TEST ACHIEVEMENT OF MEDICAL DOSIMETRY STUDENTS PARTICIPATING IN INSTRUCTION WITH SYNCHRONOUS VERSUS ASYNCHRONOUS VIDEO CONSIDERING PERSONAL LEARNING STYLE AND BLOOM'S TAXONOMY LEVEL (opens in a new tab)

  5. Development and characterization of remote radiation dosimetry systems using optically stimulated luminescence of Al2O3:C and KBr:Eu

    … and test the performance of two different dosimetry systems; one for in situ, high-sensitivity, inexpensive environmental monitoring, and another for near-real-time medical dosimetry. The systems are based on remote interrogation of the optically stimulated luminescence (OSL) from Al2O3:C …

    okstate Repository record for Development and characterization of remote radiation dosimetry systems using optically stimulated luminescence of Al2O3:C and KBr:Eu (opens in a new tab)

  6. Monte Carlo simulations for heavy ion dosimetry

    … ( ) calculations for the ionization chamber dosimetry of clinically relevant ion beams with initial energies from 50 to 450 MeV/u have been performed using the Monte Carlo technique. To simulate the transport of a particle in water the computer code SHIELD-HIT v2 was used which is a …

    heid-diss Repository record for Monte Carlo simulations for heavy ion dosimetry (opens in a new tab)

  7. Characterization and calibration of a triple-GEM detector for medical applications

    … as to determine its possible applications in medical dosimetry. The detector's response to various sources of radiation was characterized in terms of amplitude, duration, shape, and polarity of pulses, as well as its efficiency, gain, energy resolution, and temporal resolution. The triple-GEM …

    un-colombia Repository record for Characterization and calibration of a triple-GEM detector for medical applications (opens in a new tab)

  8. BEHIND THE BEAM: UNDERSTANDING CERTIFIED MEDICAL DOSIMETRISTS’ VIEWS AND ROLES IN PSA SCREENING AND PATIENT ADVOCACY

    … has examined the perspectives of Certified Medical Dosimetrists (CMDs) regarding PSA screening guidelines or patient advocacy.This dissertation examined CMD awareness of PSA screening guidelines, their beliefs regarding guideline adequacy, and their perceptions of patient advocacy. A three …

    siu-theses Repository record for BEHIND THE BEAM: UNDERSTANDING CERTIFIED MEDICAL DOSIMETRISTS’ VIEWS AND ROLES IN PSA SCREENING AND PATIENT ADVOCACY (opens in a new tab)

  9. Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations

    … tomography (CT) is one of the most important medical imaging modalities. The high patient radiation doses and frequency of examinations encountered in CT, have sparked an increased scientific and clinical interest in individual patient dose estimation. In 2014, the Council of the European …

    greece Repository record for Development of an AI-assisted computational method for the determination of individual patient radiation dose from computed tomography examinations (opens in a new tab)

  10. Re-optimization of Radiation Therapy Dose to the Prostate Using CBCT: Reducing Dose to Organs at Risk

    Cancer of the prostate is the second most common cancer among American males. The prostate is small gland, located in the pelvis, posterior to the bladder and anterior/inferior to the rectum. Due to this location when irradiating the prostate the normal tissue organs at risk are the bladder and …

    gvsu Repository record for Re-optimization of Radiation Therapy Dose to the Prostate Using CBCT: Reducing Dose to Organs at Risk (opens in a new tab)