Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning
Beam commissioning is a critical component of linear accelerator (LINAC) implementation, requiring accurate measurement of percent depth dose (PDD), beam profiles, and output factors across a wide range of field sizes. Conventional commissioning workflows often require multiple detectors and can be …
-
Neutron production and transport at a medical linear accelerator
… Teaching Hospital (VTH) uses a Varian Trilogy™ linear accelerator (linac) for radiation oncology treatment. The high-energy electron beam is used to treat superficial tumors (deep tissues are spared with this modality) or is accelerated against a target to produce high-energy photons that are …
-
Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator
… on three clinically beam matched Varian iX linear accelerators. Measurements of the beam quality (%DD(10)), peak-to-valley dose ratio (PVDR), collimator factor (CF), and relative output factor (OF) were carried out for 2 cm x 2 cm, 3 cm x 3 cm, 4 cm x 4 cm, and 5 cm x 5 cm mini-beam …
-
Advanced Statistical Process Control Techniques for Analysis of Medical Linear Accelerator Performance
… of advanced SPC techniques in order to predict medical linear accelerator dysfunction. It will also assess which data set is most effective to implement SPC techniques that can accurately reflect the behavior of a process. Specific research objectives are addressed in the designated chapters of …
-
An Interface for Analysis of Medical Linear Accelerator Parameters Using Process Behavior Charts
Modern medical linear accelerators are complex digital devices capable of producing photon and electron beams of multiple energies. These accelerators are comprised of a number of subsystems that facilitate the treatment of cancer using an expanding range of clinical approaches. Accelerator design …
-
Implementation of an Analysis Database for a Medical Linear Accelerator Monthly Quality Assurance Program
… quality assurance (QA) test results for a medical linear accelerator. The goal is to assist medical physicists in evaluating machine performance over time and determining when recalibration may be necessary, using defined tolerance thresholds. Methods: A standardized Microsoft Excel …
-
Measurements of Photo-neutrons from a Medical Linear Accelerator Using Cr-39 Plastic Nuclear Track Dtetectors
… neutron absorbed dose and dose equivalent from medical linear accelerators have been measured from the LET spectrum of recoiled tracks produced in the CR-39 PNTDs for high energy neutrons (1-20 MeV) and the neutron dose equivalent for low energy (< 1 MeV) neutrons were measured using TRNDs. In …
-
Comparative dosimetric evaluation of voxel and mesh ICRP reference phantoms in a medical linear accelerator environment
… to various organs caused by radiation from a medical linear accelerator (LINAC). A Monte Carlo radiation transport code, Particle and Heavy Ion Transport code System (PHITS), was employed for these simulations. Discrepancies in organ doses were observed between the ICRP phantoms, resulting …
-
Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning
… of metal sitting within the treatment head of a linear accelerator, used to produce a flat, uniform beam of X-rays from the forward-peaked distribution exiting the target. Despite their routine use since the introduction of the linac in the 1950’s, however, there are still several unresolved …
-
Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc
… a stereotactic ablative radiation therapy (SABR) medical linear accelerator. This MC model can simulate a variety of radiotherapy delivery techniques, including three-dimensional conformal radiotherapy (3DCRT), dynamic conformal arc (DCA) therapy, as well as complex treatments such as static-field …
-
X-Ray Induced Mutagenesis in Sunflower Pollen
… By using a 50-Gray dose of radiation from a medical linear accelerator, mutagenesis was successfully induced in sunflower at an effective, yet non-lethal level. This paper outlines the methodology behind this project and the resulting mutants.
-
Evaluation of a Modern Implementation of Dynamic Conformal Arc Therapy
… target is treated with the gantry head of the medical linear accelerator rotating around the patient while conforming the radiation beam to the target shape at each gantry angle. A modern implementation of DCAT (mDCAT) has recently been released, in which the dose rate can be varied and the …
-
Desenvolvimento de uma metodologia para equiparação de aceleradores lineares de uso médico utilizando modelagem computacional
The medical linear accelerator became the predominant equipment in radiotherapy, that is, in teletherapy. Its use requires continuous quality control due to the complexity of both the equipment and the patient. The process of dose calculation for treatment depends on several factors, mainly the …
-
Development and Realization of the IGRT Inline Concept
… for the integration of an imaging system into a medical linear accelerator for radiotherapy is presented, and its technical realization is described. An x-ray tube and a flat panel detector were installed along the treatment beam axis, such that the detector could not only be used for x-ray …
-
Characterization of a micro-ionization chamber for electron FLASH dosimetry
… beams generated by a modified Varian TrueBeam medical linear accelerator. To establish a benchmark, the performance of the CC01 chamber was compared against dose-rate independent alanine dosimeters, which are known for their stable response across various radiation dose rates. The results from …
-
Measurement of Neutron Activation from a High Energy Varian Linear Accelerator
Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced …
-
Advancements in Magnetic Resonance Image Guided Radiotherapy
… and real-time imaging capabilities of MRI with a medical linear accelerator (Linac). This provides an unprecedented ability to guide and adapt radiation therapy treatments based on real-time cine imaging. However, the merging of these technologies has come with unique challenges. MRI lacks the …
-
Monte Carlo Validation of Dose, Quality Assurance Protocols and Shielding in Radiation Therapy
… Monte Carlo study of radiation transport through medical linear accelerator treatment heads and the shielded rooms that house them. Firstly, a Monte Carlo model of the Elekta Agility treatment head in use at the Walker Family Cancer Center was created and validated using experimental data for …
-
Using Varian TrueBeam Developer Mode and Varian TrueBeam couch (6-DOF) to Simulate 4D Respiratory Motion and to Counteract the Phantom Motion in Real Time
… care and very gentle handling. However, TrueBeam medical linear accelerator allow low-level control of various machine and beam parameters under computer control and allow creation of standard motion designs by simulating equivalent couch motion for research purposes. It can incorporate patient …