Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 52 for “"Medical Physics Unit"”

  1. Developing the hydrated electron dosimeter and investigation of the G-value of hydrated electrons

    Hydrated electron (e-aq) dosimetry uses absorption spectrophotometry to monitor the concentration of e-aq, leading to the determination of absorbed dose. This technique has been employed in radiotherapy applications in the high dose-per-pulse regime (~ 10-100 Gy per pulse) for the past 60 years; …

    mcgill Repository record for Developing the hydrated electron dosimeter and investigation of the G-value of hydrated electrons (opens in a new tab)

  2. Development of dosimetry tools and dose optimization methodology for the clinical translation of intensity modulated brachytherapy for rectal cancer

    La curiethérapie à haut débit de dose utilise des sources radioactives à haute activité, typiquement de l'iridium-192, qui sont guidées temporairement à l'intérieur du corps. La curiethérapie à haut débit de dose pour le cancer rectal est utilisée dans deux applications distinctes : pour la …

    mcgill Repository record for Development of dosimetry tools and dose optimization methodology for the clinical translation of intensity modulated brachytherapy for rectal cancer (opens in a new tab)

  3. Image registration for dose accumulation between external beam radiotherapy and brachytherapy for cervical cancer: Comparison to clinical practice

    … by using Velocity software v4.1 (Varian Medical Systems, Palo Alto, California, USA). All five patients had CT scans from the EBRT treatment and 2 MR image sets from the first (BT1) and third (BT3) BT fractions, corresponding to 2 different BT implants. Each BT implant was delivered over …

    mcgill Repository record for Image registration for dose accumulation between external beam radiotherapy and brachytherapy for cervical cancer: Comparison to clinical practice (opens in a new tab)

  4. Patient-specific intravascular brachytherapy dosimetry

    Background: Cardiovascular disease is the leading cause of death globally, with coronary artery disease being its most common form. It is caused by excess plaque along the arterial wall, blocking blood flow to the heart (stenosis). A percutaneous coronary intervention widens the arterial wall with …

    mcgill Repository record for Patient-specific intravascular brachytherapy dosimetry (opens in a new tab)

  5. Dosimetric evaluation of an improved algorithm for computed tomography synthesis

    Radiotherapy is one of the primary approaches used to treat cancer, which involves the use of ionizing radiation such as photons and electrons. The radiation dose damages cells and controls their growth and division. Radiotherapy is often delivered from an external source of ionizing radiation, …

    mcgill Repository record for Dosimetric evaluation of an improved algorithm for computed tomography synthesis (opens in a new tab)

  6. Dose-to-outcome modeling for lung robotic stereotactic body radiation therapy

    L'algorithme Ray-Tracing du CyberKnife est une méthode de calcul de dose rapide en grande partie dû à sa simplicité. Cependant, plusieurs études ont démontré que cet algorithme surestime la dose au volume cible prévisionel (PTV) lorsqu'il est utilisé pour les plans de traitement du cancer du …

    mcgill Repository record for Dose-to-outcome modeling for lung robotic stereotactic body radiation therapy (opens in a new tab)

  7. Numerical design and development of a probe-format graphite absorbed dose calorimeter for use in small-field radiotherapy

    The aim of this work is to adapt the previously developed graphite probe absorbed dose calorimeter (GPC, a.k.a. Aerrow) to be able to perform accurate and precise dosimetry in the smallest irradiation field size used in external beam radiotherapy. Using a scaled-down version of the previous Aerrow, …

    mcgill Repository record for Numerical design and development of a probe-format graphite absorbed dose calorimeter for use in small-field radiotherapy (opens in a new tab)

  8. Microdosimetric evaluation of photon emitting brachytherapy sources in tissue-specific models

    Les effets biologiques des rayonnements ionisants dépendent du tissus, du type de tumeur, de la qualité du rayonnement et des facteurs spécifiques au patient. Les variations de la taille des cellules / noyaux peuvent influencer la réponse d’un patient spécifique à la dose. Cependant, cette …

    mcgill Repository record for Microdosimetric evaluation of photon emitting brachytherapy sources in tissue-specific models (opens in a new tab)

  9. Robust phase pre-processing for quantitative susceptibility mapping

    … are as follows: to develop a foundation of MRI physics with a focus on the development of phase data and multi-echo MRI sequences; to review the literature of QSM, with a focus on the pre-processing steps; to provide a comparison of spatial unwrapping techniques currently available in the field …

    mcgill Repository record for Robust phase pre-processing for quantitative susceptibility mapping (opens in a new tab)

  10. Measurement of neutron fluence spectra using a passive nested neutron spectrometer with gold foils

    … de réactions de capture de neutrons (n, g) par unité de fluence neutronique enfonction de l’énergie des neutrons (c’est-à-dire la réponse du détecteur). Les fonctions de réponse générées ont montré que la réponse du détecteur passe à des énergies plus élevées à mesure que l’épaisseur du …

    mcgill Repository record for Measurement of neutron fluence spectra using a passive nested neutron spectrometer with gold foils (opens in a new tab)

  11. Characterizing the mutational signature of photons through single cell whole genome sequencing

    L'efficacité biologique relative des neutrons (RBE) a été estimée au moyen de divers moyens notamment avec des simulations informatiques et des expériences biologiques au fil des ans. Cependant, les mesures RBE des neutrons manquent de consensus, en partie parce que le RBE dépend fortement de …

    mcgill Repository record for Characterizing the mutational signature of photons through single cell whole genome sequencing (opens in a new tab)

  12. Predictive modeling of post radiation-therapy recurrence for gynecological cancer patients using clinical and histopathology imaging features

    La modélisation des résultats peut caractériser le comportement d’une réponse tissulaire à un traitement qui est basé sur des données multi-omiques spécifiques au patient (par ex. informations cliniques, démographie, profils dosimétriques, radiomique, génomique, protéomique et pathologie). Elle …

    mcgill Repository record for Predictive modeling of post radiation-therapy recurrence for gynecological cancer patients using clinical and histopathology imaging features (opens in a new tab)

  13. Development of a small, cost-efficient scintillation detector for use in automated synthesis of PET radiopharmaceuticals.

    … process has been broken downinto basic automated unit operations, executed within a synthesis module placed inside a hot cell. Within the synthesis module, radiation detectors play a key role by allowing the radiochemists to monitor radioactivity transfer across compartments and ensure the …

    mcgill Repository record for Development of a small, cost-efficient scintillation detector for use in automated synthesis of PET radiopharmaceuticals. (opens in a new tab)

  14. A microdosimetric analysis of the interactions of mono-energetic neutrons with human tissue

    … Building on recent work, this thesis studies the physics underlying neutron RBE by using the microdosimetric quantity dose-mean lineal energy (yD) as a proxy.A simulation pipeline was constructed to explicitly calculate the yD of radiation fields that consists of (i) the open source Monte Carlo …

    mcgill Repository record for A microdosimetric analysis of the interactions of mono-energetic neutrons with human tissue (opens in a new tab)

  15. Towards a relaxation-based MR-oximetry technique for the measurement of tumor hypoxia

    … Imaging tumour hypoxia would, therefore, provide medical teams with important insights to tailor treatment approaches and improve outcomes. Magnetic ressonance imaging (MRI)-based oximetry with endogenous contrast relies on the sensitivity of the $R_2^*$ relaxation rate to changes in blood …

    mcgill Repository record for Towards a relaxation-based MR-oximetry technique for the measurement of tumor hypoxia (opens in a new tab)

  16. Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK

    Mixed electron-photon beam radiation therapy (MBRT) is an emerging treatment technique that combines both particles in a single plan to exploit their advantageous characteristics. An MBRT plan uses multiple beam energies and a large number of apertures to achieve a highly conformal dose to the …

    mcgill Repository record for Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK (opens in a new tab)

  17. Using Colour Image Segmentation with Magnetic Resonance Images for Computed Tomography Synthesis

    Mostly known for its use in cancer care, radiotherapy is a treatment modality that uses ionizing radiation to kill malignant cells. This form of therapy requires careful planning that for nearly three decades has been based on computed tomography (CT) images, from which the position of tumours and …

    mcgill Repository record for Using Colour Image Segmentation with Magnetic Resonance Images for Computed Tomography Synthesis (opens in a new tab)

  18. On the Monte Carlo simulation of neutron-induced indirect DNA damage to estimate neutron carcinogenic potential

    The exposure of patients undergoing high-energy radiotherapy to secondary radiation of neutronsposes a serious risk of iatrogenic secondary cancer induction. Ionizing radiation, such asneutrons, inflicts damage to the DNA via energy depositions to DNA moieties (direct action)and via the radiolysis …

    mcgill Repository record for On the Monte Carlo simulation of neutron-induced indirect DNA damage to estimate neutron carcinogenic potential (opens in a new tab)

  19. Intensity modulated brachytherapy for focal prostate cancer and vaginal malignancies

    Optimizing dose distribution in brachytherapy by adjusting dwell positions and dwell times has inherent limitations in conforming the absorbed dose to the tumour's shape and sculpting it around organs at risk (OARs). This is largely due to the near-isotropic dose distribution of conventional …

    mcgill Repository record for Intensity modulated brachytherapy for focal prostate cancer and vaginal malignancies (opens in a new tab)

  20. Robust characterization of longitudinal magnetic resonance relaxation with application to novel nanoparticles

    La cartographie T_1 a une multitude d'applications dans le domaine de la recherche en imagerie par résonance magnétique (IRM). L'objectif global était d'utiliser la cartographie T_1 pour caractériser des nanoparticules (NPs) théranostiques à base de lanthanide comme agents de contraste (AC) pour …

    mcgill Repository record for Robust characterization of longitudinal magnetic resonance relaxation with application to novel nanoparticles (opens in a new tab)