Anthropomorphic Model for Medical Image Quality Assessment
… dissertation explores advancements in task-based image quality assessment through the development and evaluation of an anthropomorphic visual search model observer. The model incorporates a novel threshold mechanism inspired by human visual system principles, particularly emphasizing the selective …
-
Feasibility of a user-independent systematic method for medical image quality assessment
Commonly used image quality assessment methods are influenced by the user manual selection, or the algorithm automatic selection, of a Region of Interest (ROI). An ROI is used in measurements of the signal mean, the signal standard deviation, and a signal representing the system response such as an …
-
Task-Based Medical Image Quality Assessment by Numerical Observer : Use case of adrenal CT imaging
La qualité des images naturelles peut être évaluée perceptivement, selon le critère intuitif de l’esthétique, et scientifiquement, à l’aide de métriques d’évaluation de la qualité d’image (IQA) ; Cependant, les images médicales ne disposent pas de standards communs ni de métriques mathématiques …
-
Comparison of AI/ML and image processing algorithms for modern medical applications
Noise in medical imaging, especially in low-dose CT scans, poses significant challenges to accurate diagnosis. This dissertation explores and compares classical and deep learning-based denoising algorithms to identify effective methods for enhancing medical image quality while preserving structural …
-
Learning with imperfect datasets in medical image segmentation
Medical image segmentation partitions medical images into distinct physiological regions, such as organs and lesions, essential for diagnosis and treatment planning. Deep neural networks have advanced this field recently, yet real-world performance remains unsatisfactory due to imperfect data and …
-
Investigation of optical and imaging characteristics of fluorescent screens for use in digital imaging detectors suitable for telemedicine
… detection digital imaging systems used in medical imaging, compromises powder phosphor scintillators as X-ray to light converters. Powder phosphors should combine image quality and light output parameters in order to produce high quality diagnostic images, with the parallel dose reduction …
-
Investigation of optical and imaging characteristics of fluorescent screens for use in digital imaging detectors suitable for telemedicine
… detection digital imaging systems used in medical imaging, compromises powder phosphor scintillators as X-ray to light converters. Powder phosphors should combine image quality and light output parameters in order to produce high quality diagnostic images, with the parallel dose reduction …
-
Model observers for predicting human performance on signal detection tasks.
… have been applied to the objective assessment of medical image quality. However, the relevance of this application to clinical efficacy depends largely on how well model observers predict human performance. Attempting to answer this question, this dissertation focuses on the investigation of a …
-
Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer
The goal of medical imaging is to acquire and display images of human anatomy and function such that they can be optimally interpreted by a trained observer, e.g., a radiologist. Start-of-art medical image quality is measured by the performance of an observer on a given clinical task. Since …
-
Quality control of medical film digitizers
Medical film digitizers play an important transitory role as digital to analogue bridges inradiology. Their use requires performance evaluation to assure high medical image quality. The aim of this work was to design and develop a quality assurance procedure for medical film digitizers. A complete …
-
DESIGN AND DEVELOPMENT OF A MEGAVOLTAGE CT SCANNER FOR RADIATION THERAPY.
… volume and high contrast scout-mode verification images and (iii) to provide a means for periodically checking the patients anatomical conformation against what was used to generate the original therapy plan. The treatment machine was modified by mounting an array of detectors on a frame bolted to …
-
A Unified Probabilistic Computational Framework for Cross-Domain Compensated Medical Imaging
The quality of medical imaging is an important factor that can directly affect on the results of different medical imaging tests which routinely being used for various clinical studies and related research. The existence of any type of image imperfection such as different noise and artifacts can make …
-
Visual-Search Model Observers in Assessing CT Acquisition Parameters
Medical images are commonly used by radiologists for diagnostic purposes. With the ever-evolving technology in the medical imaging systems’ technology, radiologists and medical experts face numerous choices between different imaging modalities, acquisition protocols, and reconstruction algorithms. …
-
Learning Effectively from Medical Imaging Datasets
… (CNNs) are playing important roles in developing image-based automated disease recognition and analysis systems. However, training such an automated medical image analysis system often requires large amounts of well annotated medical imaging data. The high costs of collecting and labelling medical …
-
Learning Effectively from Medical Imaging Datasets
… (CNNs) are playing important roles in developing image-based automated disease recognition and analysis systems. However, training such an automated medical image analysis system often requires large amounts of well annotated medical imaging data. The high costs of collecting and labelling medical …
-
Reporting on radiographic images in after-hours trauma units :Experiences of radiographers and medical practitioners
… or a delay in reporting on radiographic images even in emergency situations. In order to mitigate and alleviate the situation, and optimise the utilisation of radiographers a red dot system was introduced in the United Kingdom, which later aided in the transformation of the role of …