Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 59 for “"Membrane action"”

  1. Membrane action in simply supported slabs

    Abstract unavailable please refer to PDF

    heriot-watt Repository record for Membrane action in simply supported slabs (opens in a new tab)

  2. Compressive Membrane Action In Bridge Deck Slabs

    … analysis of restrained slab strips shows that membrane action enhances serviceability behaviour. However, the enhancement is not as great as for strength and serviceability is critical when membrane action is considered in design. A relatively simple form of non-linear finite element analysis …

    plymouth Repository record for Compressive Membrane Action In Bridge Deck Slabs (opens in a new tab)

  3. Punching failure and compressive membrane action in reinforced concrete slabs

    This study of punching failure and compressive membrane action in reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to concentrated loadings.The results of an extensive series of tests on one quarter scale models of the …

    qu-belfast Repository record for Punching failure and compressive membrane action in reinforced concrete slabs (opens in a new tab)

  4. Numerical Modelling of Tensile Membrane Action in Reinforced Concrete Beams

    … enhanced through the development of membrane actions if sufficient lateral restraints are provided. Membrane actions include two distinct mechanisms: compressive membrane action (CMA) and tensile membrane action (TMA) or catenary action. CMA is activated sequentially after the …

    chalmers Repository record for Numerical Modelling of Tensile Membrane Action in Reinforced Concrete Beams (opens in a new tab)

  5. Tensile membrane action of reinforced concrete slabs at ambient and elevated temperatures.

    … to the Simple Design Method which incorporates membrane action of composite floor slabs into the estimation of their load capacity in fire and shows that the design method compares well with experimental results and is generally conservative. The numerical results at ambient temperature showed …

    whiterose Repository record for Tensile membrane action of reinforced concrete slabs at ambient and elevated temperatures. (opens in a new tab)

  6. The Tensile Membrane Action of Non-orthogonal Composite Slabs at Elevated Temperatures

    … at high deflections, which utilizes tensile membrane action in the slabs, the meshing of such floor systems cannot be restricted to orthogonal grids. A separate but related issue is that nonlinear numerical modelling of internal slab panels with continuity across their edges has shown that …

    whiterose Repository record for The Tensile Membrane Action of Non-orthogonal Composite Slabs at Elevated Temperatures (opens in a new tab)

  7. Evaluation of tensile and compressive membrane action in isolated slab column specimen

    … mechanisms such as compressive and tensile membrane action may enhance the strength and ductility of a slab and arrest the progression of the collapse. It is hoped that providing sufficient in-plane lateral restraint on an isolated slab-column specimen with continuous reinforcement will …

    missouri Repository record for Evaluation of tensile and compressive membrane action in isolated slab column specimen (opens in a new tab)

  8. An Investigation into tensile membrane action as a means of emergency load redistribution

    … non-military) buildings subjected to malicious actions and has also investigated the capability of tensile membrane (catenary) action as a means of emergency load redistribution in reinforced concrete (RC) framed buildings, designed in accordance with BS 8110 and Eurocode 2.<br/><br/>Case …

    soton Repository record for An Investigation into tensile membrane action as a means of emergency load redistribution (opens in a new tab)

  9. Compressive membrane action and the ultimate capacity of uniformly loaded reinforced concrete slabs.

    This research into compressive membrane action and the ultimate capacity of reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to uniformly distributed loading. <br/><br/>The results of a series of tests on both one-way …

    qu-belfast Repository record for Compressive membrane action and the ultimate capacity of uniformly loaded reinforced concrete slabs. (opens in a new tab)

  10. Reliability-Based design for robustness : evaluation of progressive collapse in concrete structures taking into account membrane action

    Constructieve veiligheid en robuustheid zijn twee bijzondere aandachtspunten geworden bij het ontwerp van bouwkundige constructies. De significante gevolgen gerelateerd aan enkele catastrofale instortingen in de voorbije decennia, hebben het belang van deze aspecten dan ook in de schijnwerpers …

    ghent Repository record for Reliability-Based design for robustness : evaluation of progressive collapse in concrete structures taking into account membrane action (opens in a new tab)

  11. Experimental and numerical analysis of tensile membrane action in reinforced concrete slabs in the framework of structural robustness

    … the European Standard EN 1991-1-7 (2006) ‘Actions on structures – Part 1-7: Accidental actions’ points to strategies to enhance structural robustness, emphasising amongst others the favourable contribution of developing alternate load paths in case of abnormal loading events. The …

    ghent Repository record for Experimental and numerical analysis of tensile membrane action in reinforced concrete slabs in the framework of structural robustness (opens in a new tab)

  12. Behaviour of Axially Restrained Concrete Slabs

    … the combined effect of bending and compressive membrane action. The existing methods for allowing for membrane action in predicting the plastic behaviour of reinforced concrete slabs are reviewed and their limitations outlined. A new theory of the plastic behaviour of materials with tension …

    ucl Repository record for Behaviour of Axially Restrained Concrete Slabs (opens in a new tab)

  13. A mathematical reconstruction of the frog atrial action potential based on voltage clamp data

    … These models are then combined, and a membrane action potential is reconstructed based on the analyzed ionic current data. This membrane action potential is then used as input to a nonlinear least-squares fitting routine in an attempt to accurately fit the model to experimental action …

    rice Repository record for A mathematical reconstruction of the frog atrial action potential based on voltage clamp data (opens in a new tab)

  14. Development of a Mechanically Correct Fire Resistance Design Process for Composite Floor systems in Buildings

    An alternative simplified method of tensile membrane action (TMA) of thin-flat concrete slabs at ambient temperature was extended to consider composite slabs in fire. The existing simplified method (Bailey-BRE) of estimating the influence of tensile membrane action on the slab strength in fire has …

    whiterose Repository record for Development of a Mechanically Correct Fire Resistance Design Process for Composite Floor systems in Buildings (opens in a new tab)

  15. The Study of Glyceraldehyde -3 -Phosphate Dehydrogenase (Gapdh) Function Targeted by Estrogen and Progesterone in the Central Nervous System: Physiological Implications

    … results and describes a proposed model for the membrane action of estradiol on GAPDH in the hippocampus that reflects recent interesting reports from other laboratories as well as my own contributions to these novel functions of GAPDH.

    uiuc Repository record for The Study of Glyceraldehyde -3 -Phosphate Dehydrogenase (Gapdh) Function Targeted by Estrogen and Progesterone in the Central Nervous System: Physiological Implications (opens in a new tab)

  16. Progressive collapse mitigation using CMA in RC framed buildings

    … for some time that the omission of compressive membrane action (CMA), also termed ‘arching action’, can lead to a significant underestimation of load capacity. An investigation has been conducted to ascertain whether the additional load carrying capacity from CMA can provide an inherent …

    soton Repository record for Progressive collapse mitigation using CMA in RC framed buildings (opens in a new tab)

  17. The real strength of laterally restrained reinforced concrete slabs

    It is widely recognised that Compressive Membrane Action (CMA ) is the reason for the strength enhancement exhibited by laterally restrained slab system . This strength enhancement is in excess of that estimated by standard flexural and shear design methods.<br/><br/>Although of the fact that the …

    qu-belfast Repository record for The real strength of laterally restrained reinforced concrete slabs (opens in a new tab)

Page 1 of 3