Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"Metal stent"”.

  1. Designing a braided bioabsorbable magnesium metal stent

    Bioabsorbable biliary stents, made from magnesium, zinc or iron, offer a promising solution to address complications of traditional stents, such as inflammation and recurrent procedures. This study focused on developing a braided bioabsorbable stent made out of Magnesium alloy WE22, developing and …

    bu Repository record for Designing a braided bioabsorbable magnesium metal stent (opens in a new tab)

  2. Fully Covered,Retrievable Self-Expanding Metal Stent(Niti-S) in Palliation of Malignant Esophageal Obstruction

    "Background: The covered self expanding metal stent (SEMS) has become the main treatment option of malignant esophageal obstruction. However, the fully covered SEMS has not been as popular as the partially covered one for the fear of migration in spite of much advantage. So, we performed a …

    ajou Repository record for Fully Covered,Retrievable Self-Expanding Metal Stent(Niti-S) in Palliation of Malignant Esophageal Obstruction (opens in a new tab) Embargoed until 9999-12-31

  3. Traumatic arterial dissection of the lower extremity: computed tomography findings and endovascular management

    … angioplasty was primarily performed while stenting was reserved for cases of ineffective initial balloon angioplasty. Computed tomography (CT) findings, treatment results, and patient outcomes were assessed. Technical success was defined as recanalization of injured vessels in completion …

    ajou Repository record for Traumatic arterial dissection of the lower extremity: computed tomography findings and endovascular management (opens in a new tab) Embargoed until 9999-12-31

  4. Η διαδερμική χρήση επικαλυμμένων με ePTFE/FEP ενδοπροθέσεων στην αντιμετώπιση των κακοήθους αιτιολογίας στενώσεων των χοληφόρων

    Purpose: The definition of the role of ePTFE/FEP metallic covered endoprostheses in the palliation of malignant jaundice. Methodology: in the feasibility study 36 patients with malignant jaundice were included in which an ePTFE/FEP covered endoprosthesis was deployed (fully covered or with side …

    greece Repository record for Η διαδερμική χρήση επικαλυμμένων με ePTFE/FEP ενδοπροθέσεων στην αντιμετώπιση των κακοήθους αιτιολογίας στενώσεων των χοληφόρων (opens in a new tab)

  5. Μηχανισμοί εμφράγματος που αποδίδεται σε θρόμβωση ενδοστεφανιαίας ενδοπρόσθεσης (STENT) με τη χρήση της οπτικής συνετικής τομογραφίας

    … infarction (MI) occurring late following stenting may be related to either the stent or disease progression at the same or other coronary arteries.1 Stent-related MI involves stent thrombosis, with or without restenosis. Pathologic and intravascular ultrasoundstudies have shown that …

    greece Repository record for Μηχανισμοί εμφράγματος που αποδίδεται σε θρόμβωση ενδοστεφανιαίας ενδοπρόσθεσης (STENT) με τη χρήση της οπτικής συνετικής τομογραφίας (opens in a new tab)

  6. Tulžies latakų anastomozės ir jų komplikacijų gydymas. Sisteminė analizė /

    … The most common complication of these methods is stent occlusion—4.66 %. The most popular stent is the metal stent that closes the lumen, 49.14 %. Conclusions. A review of the literature showed that open surgical techniques remain the most commonly performed procedures. The most common technique …

    vilnius Repository record for Tulžies latakų anastomozės ir jų komplikacijų gydymas. Sisteminė analizė / (opens in a new tab)

  7. Η επίδραση των εμποτισμένων με διάφορες φαρμακευτικές ουσίες μεταλλικών ενδοπροθέσεων στο τοίχωμα των νεφρικών αρτηριών

    … have proposed the use of drug-eluting metal stents (MS) to improve clinical and angiographic outcomes. Based on these reports, we used paclitaxel-eluting MS within an animal renal artery lumen and compared the results with those using a bare-metal stent.Materials and methods The …

    greece Repository record for Η επίδραση των εμποτισμένων με διάφορες φαρμακευτικές ουσίες μεταλλικών ενδοπροθέσεων στο τοίχωμα των νεφρικών αρτηριών (opens in a new tab)

  8. Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου

    Purpose: Drug eluting stents (DES) proved to minimize neointimal hyperplasia in coronary vessels. Hyperplastic reaction is the most common unwelcome event related to the use of metal mesh stents in the ureter. We evaluated the effect of zotarolimus eluting stent (ZES- Endeavor Resolute, Medtronics …

    greece Repository record for Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου (opens in a new tab)

  9. Conducting polymers as novel coatings for optimised drug release from coronary stents

    … Coronary Angioplasty (PTCA) procedure, where a metal stent is implanted into the artery to provide mechanical support to ensure the artery does not become renarrowed. Today, the most advanced PTCA procedures use drug-eluting stents, and although these have improved outcomes in many cases, they …

    strathclyde Repository record for Conducting polymers as novel coatings for optimised drug release from coronary stents (opens in a new tab)

  10. Πρόκληση υπερτροφίας αριστερής κοιλίας μετά από πειραματική στένωση κατιούσης θωρακικής αορτής σε κονίκλους Νέας Ζηλανδίας

    … aortic catheterization. Under fluoroscopy a bare metal stent was partially deployed in the descending thoracic aorta (balloon length / stent length = 1 / 2) so as to produce a funnel-shaped thoracic stent. Another 9 animals underwent a sham procedure without stent placement (control). Follow-up …

    greece Repository record for Πρόκληση υπερτροφίας αριστερής κοιλίας μετά από πειραματική στένωση κατιούσης θωρακικής αορτής σε κονίκλους Νέας Ζηλανδίας (opens in a new tab)

  11. Development and Evaluation of a Nanomatrix Coated Stent Using a Vascular Sheet With Atherosclerosis Model

    While cardiovascular stent technology has considerable advances, there are hurdles to overcome due to the dysfunctional stented arteries which fail to maintain vascular homeostasis. Current stent designs ignored the significance of promoting functional artery healing (pro-healing). Therefore, we …

    uab Repository record for Development and Evaluation of a Nanomatrix Coated Stent Using a Vascular Sheet With Atherosclerosis Model (opens in a new tab)

  12. Development and Utilization of a Tissue Engineered Blood Vessel Mimic to Assess the Neointimal Response to Intravascular Stents

    The use of intravascular stents to restore blood flow through restricted vessels in patients with coronary artery disease has become the preferred method for treating a variety of lesion locations and pathologies. As new stent configurations and coatings are developed, a great need exists for …

    arizona-thes Repository record for Development and Utilization of a Tissue Engineered Blood Vessel Mimic to Assess the Neointimal Response to Intravascular Stents (opens in a new tab)

  13. Clinical, Invasive and Non-Invasive Factors Affecting Outcomes in Patients with Acute Coronary Syndromes

    … costs, selective criteria for drug-eluting stents (DES), which reduce restenosis, were developed in 2003 at Liverpool Hospital, Sydney, Australia. Clinical outcomes were examined in 2075 patients undergoing PCI (29% ≥1 DES and 71% bare metal stent [BMS]); there were no differences …

    unsw Repository record for Clinical, Invasive and Non-Invasive Factors Affecting Outcomes in Patients with Acute Coronary Syndromes (opens in a new tab)

  14. Prohealing Multifunctional Endothelium Nanomatrix Coated Stents

    … in the United States, and indeed, worldwide. Stents are the most commonly implanted devices used to treat cardiovascular disease. Bare metal stent use remains limited by relatively high rates of in-stent restenosis, a re-narrowing of the artery after stent deployment. Restenosis within stents …

    uab Repository record for Prohealing Multifunctional Endothelium Nanomatrix Coated Stents (opens in a new tab)

  15. Application of discrete multiphysics to fluid-structure-interaction simulation of vascular flows

    … fluid (blood) and solid (arterial wall and stent) within a coronary artery implanted with a metal stent. In the case of aortic valve, the effects of various calcification stages (ranging from mild to severe) on cardiac output were simulated and evaluated. It was found that increasing levels …

    birmingham Download PDF for Application of discrete multiphysics to fluid-structure-interaction simulation of vascular flows (opens in a new tab)

  16. Characterization and Implementation of a Decellularized Porcine Vessel as a Biologic Scaffold for a Blood Vessel Mimic

    … angioplasty procedures in combination with a metal stent often result in successful restoration of normal blood flow. However, bare metal stents often lead to restenosis and other complications. To compensate for this problem, industry has created drug-eluting stents to promote healing of the …

    calpoly Repository record for Characterization and Implementation of a Decellularized Porcine Vessel as a Biologic Scaffold for a Blood Vessel Mimic (opens in a new tab)

Page 1 of 2