Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"Metallic biomaterials"”.

  1. A Rubric for Electrochemical Testing of Metallic Biomaterials

    Corrosion is a major factor for the failure of metallic medical implants. Testing a metal’s suseptability to corrosion prior to implantation is key to a successful implantation. Electrochemical processes were used in this study to evaluate the characteristics of corrosion of both AISI 316 stainless …

    calpoly Repository record for A Rubric for Electrochemical Testing of Metallic Biomaterials (opens in a new tab)

  2. Surface Engineering and Characterization of Laser Deposited Metallic Biomaterials

    Novel net shaping technique Laser Engineered Net shaping™ (LENS) laser based manufacturing solution (Sandia Corp., Albuquerque, NM); Laser can be used to deposit orthopedic implant alloys. Ti-35Nb-7Zr-5Ta (TNZT) alloy system was deposited using LENS. The corrosion resistance being an important …

    unt Repository record for Surface Engineering and Characterization of Laser Deposited Metallic Biomaterials (opens in a new tab)

  3. The Fundamentals of Fretting Crevice Corrosion of Metallic Biomaterials for Orthopedic Implants

    Metallic medical devices have been widely used in clinical applications, especially for joint arthroplasty or joint replacement surgery. Fretting corrosion, one of the most common forms of mechanically-assisted corrosion (MAC), has become a major concern associated with orthopedic medical devices. …

    clemson Repository record for The Fundamentals of Fretting Crevice Corrosion of Metallic Biomaterials for Orthopedic Implants (opens in a new tab)

  4. The effect of bleaching agents on mineralised tooth tissues and metallic biomaterials

    … to cause adverse changes to dental tissues and biomaterials. The aim of this research was to assess the effect of varying concentrations of bleaching agents on (i) tooth demineralisation and microhardness, and (ii) metal ion release from dental amalgams and casting alloys. Freshly extracted …

    whiterose Download PDF for The effect of bleaching agents on mineralised tooth tissues and metallic biomaterials (opens in a new tab)

  5. Single Asperity Fretting Corrosion of Traditional and Additively Manufactured Metallic Biomaterials: Quantitative Analysis from Acetabular Tapers to Micron and Nanometer Scale Tribocorrosion

    Mechanically assisted crevice corrosion (MACC) of metallic biomaterials continues to be a significant degradation mode. This is, in part, due to a lack of understanding of fundamental micron- and sub-micron scale mechanisms of metal degradation in biological environments. Metal-metal (or …

    clemson Repository record for Single Asperity Fretting Corrosion of Traditional and Additively Manufactured Metallic Biomaterials: Quantitative Analysis from Acetabular Tapers to Micron and Nanometer Scale Tribocorrosion (opens in a new tab)

  6. Electrochemical Assessment of Alumina-TiC Composite: A Potential Biomaterial

    … composites are gaining popularity over their metallic counterparts for orthopedic applications. Metallic biomaterials, like titanium alloys and CoCrMo alloy, exhibit good performance under concentrated loads but there have been plenty cases of implant failure due to release of metallic debris …

    clemson Repository record for Electrochemical Assessment of Alumina-TiC Composite: A Potential Biomaterial (opens in a new tab)

  7. In Vitro Polarization Evaluation of Carbon-Metal Galvanic Couples.

    … been recognized as a problem with synthetic, metallic materials for applications in biological environments. This is one of the main reasons type 316L stainless steel and Ti-6Al-4V ELI-grade alloy have emerged as two of the more widely used metallic biomaterials. In recent years with more and …

    uab Repository record for In Vitro Polarization Evaluation of Carbon-Metal Galvanic Couples. (opens in a new tab)

  8. Corrosion behavior of metallic bio-implant alloys

    The most common metallic biomaterials are 316L, Co-28Cr-6Mo, and Ti-6Al-4V alloys used as prostheses and fixation devices. These materials are biocompatible and have high corrosion resistance. However, metallic biomaterials are not completely inert in the body. The presence of dissolved oxygen, …

    ubc Repository record for Corrosion behavior of metallic bio-implant alloys (opens in a new tab) Download PDF for Corrosion behavior of metallic bio-implant alloys (opens in a new tab)

  9. Ajuste das propriedades de superfície do titânio via μPPEO para melhorar a osseointegração e a adesão celular

    … with direct applications in dental implants and biomaterials. μPPEO is a promising approach for surface modification of metallic biomaterials aimed at bone regeneration and drug delivery systems.

    brazil-ufrn Repository record for Ajuste das propriedades de superfície do titânio via μPPEO para melhorar a osseointegração e a adesão celular (opens in a new tab)

  10. Surface modification of ASTM F-1537 Co-Cr alloy by low temperature plasma surface alloying

    … (Co-Cr) alloys are one of the most suitable metallic biomaterials especially for high load body implants. However, recently, there are concerns over the wear of metal-on- metal artificial hip joints made from Co-Cr alloys due to the formation of numerical nano- sized wear debris from the …

    birmingham Download PDF for Surface modification of ASTM F-1537 Co-Cr alloy by low temperature plasma surface alloying (opens in a new tab)

  11. The response of ASTM F1537 Co-28Cr-6Mo alloy with different phase constituents to low-temperature plasma carburising

    Co-Cr alloys are the most widely used metallic biomaterials for metal-on-metal joint prostheses. However, concerns about increased revision rate associated with metal-on-metal replacements have been raised recently. This research was aimed at studying the response of medical grade ASTM Fl537 …

    birmingham Download PDF for The response of ASTM F1537 Co-28Cr-6Mo alloy with different phase constituents to low-temperature plasma carburising (opens in a new tab)

  12. ADDITIVELY MANUFACTURED BETA–TI ALLOY FOR BIOMEDICAL APPLICATIONS

    Metallic biomaterials have an essential portion of uses in biomedical applications. Their properties can be tuned by many factors resulting in their process tuneability. Among metallic biomaterials for biomedical and specifically orthopedic applications, titanium and its alloys exhibit the most …

    trento Repository record for ADDITIVELY MANUFACTURED BETA–TI ALLOY FOR BIOMEDICAL APPLICATIONS (opens in a new tab) Download PDF for ADDITIVELY MANUFACTURED BETA–TI ALLOY FOR BIOMEDICAL APPLICATIONS (opens in a new tab)

  13. Tin-Silver as a Novel Biodegradable Metallic Biomaterial

    … tissue, documenting signs of degradation and metallic degradation products, then to characterize the electrochemical behavior of Sn-Ag in biologically representative environments and finally, to assess the biological interaction of Sn-Ag. Retrieval analyses developed successful methods, …

    clemson Repository record for Tin-Silver as a Novel Biodegradable Metallic Biomaterial (opens in a new tab)

  14. The effects of cathodic polarization and simulated infection on the electrochemical properties of CoCrMo and coupled Ti6Al4V+CoCrMo alloy

    Metallic biomaterials are the most commonly used materials for medical devices because of their unique combination of; strength, wear resistance, and corrosion resistance. However, they also pose some concern due to how they interact electrochemically with the body and the risk of metallic ion …

    buffalo Repository record for The effects of cathodic polarization and simulated infection on the electrochemical properties of CoCrMo and coupled Ti6Al4V+CoCrMo alloy (opens in a new tab)

  15. A Biodegradable Mg Alloy for Orthopedic Applications

    … interest as a new generation of biodegradable metallic biomaterials. Current metallic orthopedic implants cause stress shielding effects and may require removal surgery as permanent implants. The biocompatibility, biodegradability, close mechanical properties to human cortical bone tissue, …

    ucf Repository record for A Biodegradable Mg Alloy for Orthopedic Applications (opens in a new tab)

  16. Tribocorrosion and tribochemistry of cobalt-chromium alloy used for total hip replacement

    Cobalt-based metallic biomaterials are mostly employed as bearing materials for Total Hip Replacement (THR) owing to their high strength, their biocompatibility, as well as their wear and fatigue resistance. Cobalt-chromium-molybdenum (CoCrMo) alloys also have excellent passivity characteristics as …

    whiterose Download PDF for Tribocorrosion and tribochemistry of cobalt-chromium alloy used for total hip replacement (opens in a new tab)

  17. Laser Powder Bed Fusion Ta-Ti alloys for biomedical application

    Despite advancements, metallic materials for load-bearing medical applications still face ongoing challenges. Titanium (Ti) and tantalum (Ta) are widely used due to their mechanical and biological properties, but both have limitations: Ta is highly bioactive but heavy and expensive, while Ti is …

    unsw Repository record for Laser Powder Bed Fusion Ta-Ti alloys for biomedical application (opens in a new tab)

  18. Investigating the in vitro corrosion behaviour of four as-cast magnesium-zinc alloys for orthopaedic applications in Simulated Body Fluid

    The use of metallic biomaterials, such as titanium alloys, stainless steels and cobalt-chromium alloys in bone implant devices is indispensable to support the bone during the healing period. However, prolonged use of implantation devices made of these inert biomaterials may lead to stress shielding …

    ubc Repository record for Investigating the in vitro corrosion behaviour of four as-cast magnesium-zinc alloys for orthopaedic applications in Simulated Body Fluid (opens in a new tab) Download PDF for Investigating the in vitro corrosion behaviour of four as-cast magnesium-zinc alloys for orthopaedic applications in Simulated Body Fluid (opens in a new tab)

Page 1 of 2