  1. Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy

    … result in a depleted resource. Generally, flow meters need a flow profile to be fully developed so to optimizemeasurement accuracy. In order to produce accurate measurements, most flow meters require a straight section of pipe immediately upstream of the meter. The straight pipe helps to develop …

    utahstate Repository record for Partially Closed Valve Effects on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  2. The Effects of Pipewall Offsets on Water Meter Accuracy

    … of any type of fluid system. In order for a meter to accurately measure the flow, some installation requirements must be met. These installation requirements are meant to produce a condition where there are limited flow disturbances as the fluid enters the meter. If flow disturbances do …

    utahstate Repository record for The Effects of Pipewall Offsets on Water Meter Accuracy (opens in a new tab)

  3. The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy

    … measure flow is absolutely essential. For many meter designs, including electromagnetic induction meters (also known as magnetic flow meters), the greatest accuracy is achieved when the device is calibrated correctly. Optimal meter accuracy often depends on the flow conditions associated with …

    utahstate Repository record for The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy (opens in a new tab)

  4. Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy

    … profiles on electromagnetic (magnetic) flow meters. According to the American Water Works Association, “No tool available to water utilities has played a greater part in the conservation of water than the water meter (AWWA 2002).” Consequently, it is imperative to understand what variables …

    utahstate Repository record for Assessing the Effects of Local Turbulence and Velocity Profiles on Electromagnetic Flow Meter Accuracy (opens in a new tab)

  5. A robust 2.4 GHz time-of-arrival based ranging system with sub-meter accuracy : feasibility study and realization of low power CMOS receiver

    Draadloze sensornetwerken worden meer en meer aangewend om verschillende soorten informatie te verzamelen. De locatie, waar deze informatie verzameld is, is een belangerijke eigenschap en voor sommige toepassingen, zoals het volgen van personen of goederen, zelfs de meest belangrijke en …

    ghent Repository record for A robust 2.4 GHz time-of-arrival based ranging system with sub-meter accuracy : feasibility study and realization of low power CMOS receiver (opens in a new tab)

  6. Analysis of the positional accuracy of a range difference missile position measuring system

    … range differences to obtain missile TSPI with 1-meter accuracy. The TM Tracker was fielded during live missile firings and measurements indicated that the desired TSPI accuracy was not attained. This thesis examines system requirements and limitations of the TM Tracker to obtain TSPI with 1-meter …

    nps Repository record for Analysis of the positional accuracy of a range difference missile position measuring system (opens in a new tab)

  7. An investigation of effects of flow conditioning on straight tube Coriolis meter

    Coriolis meter, despite being very accurate in single phase conditions, fails to accurately measure two-phase flows. It poses a complex fluid-structure interaction problem in case of two-phase operation; there is a scarcity of theoretical models available to predict the errors reported by Coriolis …

    tamu Repository record for An investigation of effects of flow conditioning on straight tube Coriolis meter (opens in a new tab)

  8. Improvements and assessments of water auditing techniques

    … and defining procedures for assessing customer meter accuracy for a system. Application of the improved IWA audit method to SAWS discovered that its system input volume is being significantly undermeasured by current practices, current water loss control programs are very effective, customer …

    tamu Repository record for Improvements and assessments of water auditing techniques (opens in a new tab)

  9. Effect of corn variety, mechanical damage, and drying temperature on electronic moisture meters

    <p>In the grain trade, electronic moisture meters are used for most moisture content determinations. These meters provide a fast indication of moisture content by measurement of certain electrical properties of grain, most often dielectric constant;The objective of this study was to quantify the …

    iastate Repository record for Effect of corn variety, mechanical damage, and drying temperature on electronic moisture meters (opens in a new tab)

  10. Post processing of multiple GPS receivers to enhance baseline accuracy

    … Global Positioning Receivers (GPS) have typical accuracy of ±3 meters when augmented by the Wide Areas Augmentation System (WAAS). There exist applications that require position measurements between two moving targets. The focus of this work is to explore the viability of using clusters of COTS …

    mtu Repository record for Post processing of multiple GPS receivers to enhance baseline accuracy (opens in a new tab)

  11. Angular Diversity Based Visible Light Positioning

    … technology. The experiments prove that sub-meter accuracy is obtainable, even when the receiver is oriented away from the transmitter.

    mcmaster Repository record for Angular Diversity Based Visible Light Positioning (opens in a new tab)

  12. Precise positioning with AM radio stations

    … suggest that the technique is capable of sub-meter accuracy.

    manitoba Repository record for Precise positioning with AM radio stations (opens in a new tab)

  13. The Effects That Non-Recommended Conditions Have on Residential Water Meter Accuracies

    … available water becomes more and more scarce. Metering water usage is a way to make users more aware of how much water they use, which in turn will increase the desire to conserve water and to reduce their water bill. When meters are tested in their new condition, it is normally performed under …

    utahstate Repository record for The Effects That Non-Recommended Conditions Have on Residential Water Meter Accuracies (opens in a new tab)

  14. Automotive radar using IEEE 802.11p signals

    … and velocity information is encoded in the parameters of the reflected path. We estimate the parameters of the direct and reflected path using a variant of least squares matching pursuit algorithm by exploiting their relative power difference. The performance of the algorithm is evaluated …

    texas Repository record for Automotive radar using IEEE 802.11p signals (opens in a new tab)

  15. Accuracy of Residential Water Meters in Response to Short, Intermittent Flows

    In this study, water meter accuracy in response to short, intermittent flows was tested. Burst flows have short durations (a few seconds or less), and occur at a variety of flow rates. For some types of meters, it is difficult to accurately measure short, intermittent flow rates. Depending on the …

    utahstate Repository record for Accuracy of Residential Water Meters in Response to Short, Intermittent Flows (opens in a new tab)

  16. Calbration and evaluation of water speed indicator and compass for the small autonomous underwater vehicle navigation filter

    … that the SANS filter is capable of obtaining 3 meter accuracy with no Global Positioning Update for an excess of two minutes. This is well beyond the initial goals set for the system

    nps Repository record for Calbration and evaluation of water speed indicator and compass for the small autonomous underwater vehicle navigation filter (opens in a new tab)

  17. Advancing livestock welfare sensors: an optimization-based BLE & IMU localization approach

    … the algorithm successfully achieved sub 1 meter accuracy without requiring gate analysis or fingerprinting techniques. An ArUco-based camera ground truth system was established to evaluate the system performance. While the integrated IMU sensor did not directly enhance positional estimation …

    colo-mines Repository record for Advancing livestock welfare sensors: an optimization-based BLE & IMU localization approach (opens in a new tab)

  18. Scalable and Generalizable Visible Light Positioning: Spectral Sensing, Synthetic Fingerprints, and Large Language Model Integration

    … indoor localization solution, offering high accuracy and privacy preservation. However, existing VLP systems face key challenges, including sensitivity to dynamic lighting, reliance on labor- intensive fingerprint collection, and limited generalization across environments. This thesis …

    unsw Repository record for Scalable and Generalizable Visible Light Positioning: Spectral Sensing, Synthetic Fingerprints, and Large Language Model Integration (opens in a new tab)

  19. Monocular Vision for Reliable Vehicle Navigation: From Visual Semantics to Map-Based Positioning

    … a monocular RGB camera, inertial sensors, odometer measurements, and prior 3-D digital maps. Experimental results validate both contributions. The integration of camera-derived semantics improves the robustness of LiDAR odometry, increases map-matching reliability, and enables cost-effective …

    queens Repository record for Monocular Vision for Reliable Vehicle Navigation: From Visual Semantics to Map-Based Positioning (opens in a new tab)

  20. A test of differential GPS correction methods at Fort Huachuca, Arizona

    High accuracy GPS using inexpensive field equipment is increasingly made possible through use of reference data provided by the (CORS) network. There are currently three CORS within 100km of Fort Huachuca, Arizona, but use of CORS data in differential correction has previously proven unreliable. …

    missouri Repository record for A test of differential GPS correction methods at Fort Huachuca, Arizona (opens in a new tab)