Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 60 for “"Micro Particle Image Velocimetry"”
-
Micro-particle image velocimetry for lymphatic flow
… a reduced spatial resolution.The time-resolved micro-Particle Image Velocimetry technique, a well established method has been employed to study this transient flow. To that end, a bespoke light source was developed, utilising high-power light-emitting diodes, as well as associated control and …
-
Rheological and Velocity Profile Measurements of Blood in Microflow Using Micro-particle Image Velocimetry
Microhemodynamics is the study of blood flow in small vessels, usually on the order of 50 to 100 µm. The in vitro study of blood flow in small channels is analogous to the in vivo study of the microcirculation. At this scale the Reynolds and Womersly numbers are significantly less than 1 and the …
-
Blood Microflow Characterization Using Micro-Particle Image Velocimetry and 2-Beam Fluorescence Cross-Correlation Spectroscopy
Blood flow through microcirculation in both simple and complex geometry has been difficult to predict due to the composition and complex behavior of blood at the microscale. Blood is a dense suspension of deformable red blood cells that is comparable in dimensions to the microchannels that it flows …
-
In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve
… demonstrates the ability of high-resolution Micro Particle Image Velocimetry to assess the fluid flow fields within the hinges of bileaflet mechanical heart valves, which can be extended to investigate micro-scale flow domains in critical regions of other cardiovascular devices to assess …
-
A comrehensive model study for Flash Nanoprecipitation: computational fluid dynamics, micro- particle image velocimetry, and population balance modeling
… - a novel approach to produce functional nanoparticles. A mixing study has been conducted in a custom-designed microscale multi-inlet vortex reactor (MIVR) and a scalar mixing model was validated against experimental data. A microPIV experiment was conducted to further validate the turbulent …
-
Particle transport in microfluidic environments : particle adsorption at the polydimethylsiloxane-water interface and the effects of flow field and image processing on the measurement depth in micro particle image velocimetry
… questions associated with the transport of microscopic particles in microfluidic environments. This includes an investigation of the motion and deposition of micron sized polystyrene particles at the planar polydimethylsiloxane–water interface. Particle tracking shows that particles near the …
-
Experimental investigation of pore scale velocity within micro porous media
… to quantify velocity field at pore scale within micro porous media, formed by packing of micro glass spheres inside a glass micro-model, is presented. A scanning micro particle image velocimetry (µ-PIV) system is used to obtain two component two dimensional (2C2D) velocity field at two different …
-
Measurement and Modeling of Entropy Generation in Microchannels
… transfer, for predicting entropy generation in a microchannel. The model includes the effects due to developing and fully developed flow, entrance and exit geometries, cross-sectional shapes, aspect ratio, and different thermal boundary conditions. An experimental technique is presented that …
-
Investigation of Determining Velocity Profiles in Microfluidic Channel Using Micro PIV
An investigation of the velocity profile in a microscale (<5mm) channel using micro PIV technique is presented. Measuring the velocity profile in the microchannel becomes increasingly important with the improved attention to microscale devices. Theory dictates that flow in the channel has a …
-
Yield-Stress Fluids in Confined Geometries
… comparable to the characteristic scale of its microstructure. The particle size and polydispersity of two yield-stress fluids, Carbopol and poly(N-isopropylacrylamide), were determined using dynamic light scattering. A rheological characterization was performed on these two yield-stress fluids. …
-
Development of a microfluidic model system to study the response of endothelial cells to pulsatile shear
… The aims of this thesis were to develop a microfluidic chip to mimic the embryonic heart and circulation and examine the response of endothelial cell to pulsatile shear flow. The chip was manufactured in PDMS consisting of a peristaltic pump with pneumatic actuated microvalves and …
-
Smart microsystems for cell manipulations
… and testing of a passive and non-invasive micro-scale planar particle-from-fluid filter for segregating cell types from a homogeneous suspension. The microfluidics system can be used to separate spermatogenic cells from testis biopsy samples, providing a mechanism for filtrate retrieval for …
-
Development of a Vascularized Tumor-on-a-Chip for Modeling Directed Vasculogenesis in Colorectal Cancer
… chamber. This thesis develops a three-chamber microfluidic colorectal tumor-on-a-chip in which the directed interstitial-flow field is measured, spatially uniform, and tunable. Two endothelial chambers flank a central tumor chamber, and flow is driven by hydrostatic head across three flow …
-
High-speed microscale flows across obstacles for enhanced mixing
In microfluidics, mixing remains a challenge due to the diffusion-dominated nature of the flows therein. Inserting obstacles such as cylindrical pins in a micromixer has the potential to significantly enhance mixing. However, it is unclear how the mixing efficiency in confined microchannel flows is …
-
Optical Techniques for Experimental Tests in Microfluidics
… investigation of single and two-phase flows in microchannels. Different experimental techniques are presented and the achieved results are critically discussed. Firstly, the inverse use of the micro Particle Image Velocimetry technique for the detection of the real shape of the inner …
-
Micro-scale fluid flows: the application of acoustic streaming to biomedical research
… in vitro. Within the thesis, stable cavitation microstreaming was harnessed as a method for mimicking in vivo shear stress with the aim of developing a generic method for stressing cells. Stable cavitation microstreaming is a steady fluid flow generated by the transfer of acoustic energy into a …
-
Optical fiber coupled low power micro-PIV measurement of flow in microchambers : modeling, fabrication, testing and validation
Microfluidic chip is one of the important tools for modem analytical sciences. It is an important and fast developing component for applications in life science. environment science, medicine and chemistry. While its development is spread over tens of years, the basic research on flow mechanism in …
-
Liquid Flow Rates Measurements Through Graphene Nanopores by Micro-PIV
… develop a method to measure flow rates through micro and nanopores in membranes by analyzing velocity fields obtained through micro particle image velocimetry (micro-PIV). We validate our method and determine the Reynolds number limit for which it is valid by conducting experiments with …
-
In silico study of the mechanisms of cell deposition into 3D rapid prototyping scaffolds under in vitro hydrodynamic conditions
… scaffolds with controlled regular internal microstructure. However, inaccuracies in the fabrication process could deviate the actual scaffold from its intended design leading to variations in the micromechanical cell environment and thereby final tissue properties. In this thesis, a …
-
Blood flow measurement in the zebrafish heart using light sheet microscopy
… which combines selective plane illumination microscopy (SPIM), with optical gating techniques, and micro particle image velocimetry (uPIV). This combination (referred here as SPIM-uPIV) allowed non-invasively measuring blood flow in the developing zebrafish heart in a depth and time-resolved …
Page 1 of 3