Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 39 for “"Micro-CT scanner"”

  1. Advances of Interfacial Property Determination Using X-Ray Micro Imaging

    The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of …

    calgary Repository record for Advances of Interfacial Property Determination Using X-Ray Micro Imaging (opens in a new tab)

  2. Retrospectively Gated Computed Tomography in Mice

    Objective: To develop and characterize a technique for optimizing image quality in retrospectively gated micro-computed tomography (micro-CT) images of mice caused by insufficient and irregular angular sampling. Materials and Methods: A least error sorting technique was developed where, for each …

    uwo Repository record for Retrospectively Gated Computed Tomography in Mice (opens in a new tab)

  3. Development of a Three-Dimensional Image-Guided Needle Positioning System for Small Animal Interventions

    … needle positioning techniques for small animal microinjections are fraught with issues of repeatability and targeting accuracy. To improve the outcomes of these interventions a small animal needle positioning system guided by micro-computed tomography (micro-CT) imaging was developed. A phantom …

    uwo Repository record for Development of a Three-Dimensional Image-Guided Needle Positioning System for Small Animal Interventions (opens in a new tab)

  4. Radio-Translucent 3-axis Mechanical Testing Rig for Spine in Micro-CT

    … rig for spinal mechanical testing used in conjunction with a Shimadzu micro-CT scanner. Several tests were conducted to verify the feasibility of the rig design. Firstly, the rig was able to exert pure moment loading in the compression, flexion\extension and lateral bending of a goat lumbar …

    nus Repository record for Radio-Translucent 3-axis Mechanical Testing Rig for Spine in Micro-CT (opens in a new tab)

  5. Influencing factors of orthodontic tooth movement and root resorption, and evaluation of its radiographic diagnostic means

    … investigate whether patient- or tooth-related factors like jaw location or intra- and interarch obstacles influence the amount of orthodontic tooth movement and orthodontically induced root resorption, and to evaluate if the concept of slow and fast movers is valid in humans. Furthermore, to …

    goteborg Repository record for Influencing factors of orthodontic tooth movement and root resorption, and evaluation of its radiographic diagnostic means (opens in a new tab)

  6. Development and Assessment of a Micro-CT Based System for Quantifying Loaded Knee Joint Kinematics and Tissue Mechanics

    … anterior cruciate ligament (ACL) reconstruction is a highly developed surgical procedure, sub-optimal treatment outcomes persist. This can be partially attributed to an incomplete understanding of knee joint kinematics and regional tissue mechanic properties. A system for minimally-invasive …

    uwo Repository record for Development and Assessment of a Micro-CT Based System for Quantifying Loaded Knee Joint Kinematics and Tissue Mechanics (opens in a new tab)

  7. An Investigation of Electronic Cigarette Aerosol Mixture on Craniofacial Development in Mouse Embryos

    … The aim of this study was to determine the effects of exposure to e-cig aerosol mixtures (e-cigAMs) on proliferation, migration, and differentiation of NCCs in vitro and craniofacial development in mouse embryos in vivo. E-cigAM was produced by bubbling e-cig aerosol into saline. E-cigAMs were …

    vcu Repository record for An Investigation of Electronic Cigarette Aerosol Mixture on Craniofacial Development in Mouse Embryos (opens in a new tab)

  8. Silica-Based Nanoparticles: Synthesis, Characterization, And Structural Control

    … materials. This class of materials is characterized by ordered pore structures, controllable pore size, and large surface area. Significant research efforts have been devoted to achieve the control over particle size, morphology, pore size, and mesostructure. In this dissertation, I will …

    cornell Repository record for Silica-Based Nanoparticles: Synthesis, Characterization, And Structural Control (opens in a new tab)

  9. High performance digital volume correlation

    … available in the literature. Using an X-ray micro-CT scanner, we can resolve features at the 5 micron scale, generating 3D images with up to 36 billion voxels. We utilize linear and quadratic shape functions with tricubic spline interpolation to achieve high accuracy. We improve the …

    uiuc Repository record for High performance digital volume correlation (opens in a new tab)

  10. Quantitative analysis of breast lumpectomies using histology and micro-CT data

    OBJECTIVE: Breast cancer represents a significant risk in women's health, affecting many women worldwide. Current treatment options in the U.S involve a multidisciplinary approach, most often beginning with surgery to remove cancerous tissue. Evaluation of margins for cancer on excised tissue is an …

    bu Repository record for Quantitative analysis of breast lumpectomies using histology and micro-CT data (opens in a new tab)

  11. Presence of accessory canals in the furcation region of primary molars

    … region of primary molars has been the subject of extensive research. The objective of this study was to use a micro-computed tomography scanner to analyze accessory canals in the furcation region of extracted primary molars. Sixty-five primary molars which were extracted for purposes not …

    manitoba Repository record for Presence of accessory canals in the furcation region of primary molars (opens in a new tab)

  12. Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis

    … bone of short implants plateau-designed connected with different crown heights, and to compare these findings with those of regular implants. Material and Methods: Two implant designs (∅5 mm×6 mm and ∅5 mm×11 mm) and abutments (∅5 mm×9 mm and ∅5 mm×5 mm) were scanned using a micro-CT scanner. …

    umn Repository record for Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis (opens in a new tab)

  13. Automation Process for Morphometric Analysis of Volumetric CT Data from Pulmonary Vasculature of Rats

    … analysis of the rat lung vascular structure. The primary objective of our group is to develop a structural and functional understanding of pulmonary vascular remodeling (PVR). PVR can be defined as certain structural as well as biomechanical changes in the normal architecture of the …

    marquette Repository record for Automation Process for Morphometric Analysis of Volumetric CT Data from Pulmonary Vasculature of Rats (opens in a new tab)

  14. Lanthanide Nanoparticles as Contrast Agents for In Vivo Dual Energy Microcomputed Tomography of the Mouse Vasculature

    Dual energy (DE) computed tomography (CT) has the capability to influence medicine and pre-clinical research by providing quantitative information that can detect nascent lesions, identify perfusion restoration or inhomogeneities within tissues, and recognize the presence of calcium deposits. A …

    uwo Repository record for Lanthanide Nanoparticles as Contrast Agents for In Vivo Dual Energy Microcomputed Tomography of the Mouse Vasculature (opens in a new tab)

  15. Epoxidized Natural Rubber in Vibration and Noise Control Applications

    … These are referred as ENR-25 and ENR-50 respectively. ENR has been developed mainly to be used in the tyre industry, but its actual ability to control vibration and noise is poorly understood. Therefore, the aim of the research is to develop a method to design Epoxidized Natural Rubber (ENR) …

    whiterose Repository record for Epoxidized Natural Rubber in Vibration and Noise Control Applications (opens in a new tab)

  16. External and internal carpal morphology of knuckle-walking apes among mammals

    … Little work, however, has focused on the effect of body size on carpal morphology, or on the internal trabecular structure of carpals. Here, I analyze the relationship between external carpal morphology and estimated body mass (EBM) in African apes among mammals, and the internal trabecular …

    jhu Repository record for External and internal carpal morphology of knuckle-walking apes among mammals (opens in a new tab)

  17. Assessment of fluorescently-labeled gold nanoparticles in mice as a contrast agent for micro-computed tomography and optical projection tomography

    Objectives: Contrast agents are required to be able to view and differentiate tissues in 3-D computed tomography (CT) due to similarities in density. Pre-clinical contrast agents used for radiology are not visible when viewed histologically, and visa versa. Identifying a single agent that is …

    ubc Repository record for Assessment of fluorescently-labeled gold nanoparticles in mice as a contrast agent for micro-computed tomography and optical projection tomography (opens in a new tab)

  18. Micro-CT analysis of paraffin embedded lung tissue : is small airway obstruction an early feature of COPD?

    Rationale: Airflow obstruction, the hallmark characteristic of Chronic Obstructive Pulmonary Disease (COPD) has long been attributed to a combination of small airways disease and emphysematous destruction, however, the relative role of each pathological feature has not been well understood. …

    ubc Repository record for Micro-CT analysis of paraffin embedded lung tissue : is small airway obstruction an early feature of COPD? (opens in a new tab)

  19. An in vitro study of the failure of short-fibre reinforced composite post and core restoration of endodontically treated teeth

    … with SFRC as a post and core restoration. Objectives: To comprehensively analyse the failure of ETT restored with SFRC as a post and core by conducting the following investigations: (1) analysis of the internal structures of SFRC posts and cores using micro-CT; (2) evaluation of failure load …

    adelaide Repository record for An in vitro study of the failure of short-fibre reinforced composite post and core restoration of endodontically treated teeth (opens in a new tab)

Page 1 of 2