Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Micro-PIV"”.

  1. Micro-PIV measurement of flow through forming fabrics

    … are typically used in the paper making process. Micro Particle Image Velocimetry was used to measure the velocity distribution upstream of a forming fabric. The velocity upstream of two different types of forming fabrics, namely Monoflex D60TM and IntegraTM, was studied. As expected, the …

    ubc Repository record for Micro-PIV measurement of flow through forming fabrics (opens in a new tab) Download PDF for Micro-PIV measurement of flow through forming fabrics (opens in a new tab)

  2. Experimental study of microfluidic flow using a Micro-PIV system

    … study of a creeping flow of water inside a micro-scale rectangular cross-sectional channel (110 µm × 40 µm) using Micro-Particle Image Velocimetry (Micro-PIV). Micro-PIV is designed to achieve the micro-scale resolution required for microfluidic flow investigation. One of the most important …

    sask Repository record for Experimental study of microfluidic flow using a Micro-PIV system (opens in a new tab)

  3. Micro PIV and Numerical Investigation of a Micro-Couette Blood Flow

    … purpose of this thesis is to design a physical microchannel model for micro-Couette blood flow that provides constant and controlled conditions to study and analyze Red Blood Cell (RBC) aggregation. The innovation of this work is that the Couette blood flow is created by the motion of a second …

    ottawa-retro Repository record for Micro PIV and Numerical Investigation of a Micro-Couette Blood Flow (opens in a new tab)

  4. Micro--PIV Measurements and Numerical Simulations of Induced Charge Electro-Osmosis Around a Conducting Metal Rod

    … metal rod positioned in the center of a microchannel was analyzed through physical experimentation and numerical simulation. The experimental set up consisted of a straight microchannel connecting two fluid reservoirs with a square wave AC electric field applied across the microchannel. …

    odu Repository record for Micro--PIV Measurements and Numerical Simulations of Induced Charge Electro-Osmosis Around a Conducting Metal Rod (opens in a new tab)

  5. Optical fiber coupled low power micro-PIV measurement of flow in microchambers : modeling, fabrication, testing and validation

    Microfluidic chip is one of the important tools for modem analytical sciences. It is an important and fast developing component for applications in life science. environment science, medicine and chemistry. While its development is spread over tens of years, the basic research on flow mechanism in …

    concordia Download PDF for Optical fiber coupled low power micro-PIV measurement of flow in microchambers : modeling, fabrication, testing and validation (opens in a new tab)

  6. Study of microfluidic measurement techniques using novel optical imaging diagnostics

    Novel microscale velocity and temperature measurement techniques were studied based on confocal laser scanning microscopy (CLSM) and optical serial sectioning microscopy (OSSM). Two microscopic measurement systems were developed, 1) a CLSM micro particle image velocimetry (PIV) system with a dual …

    tamu Repository record for Study of microfluidic measurement techniques using novel optical imaging diagnostics (opens in a new tab)

  7. Experimental and computational investigation of turbulent mixing in microscale reactors

    … as the particle morphology. Turbulent mixing in microscale nanoprecipitation reactors, i.e., the planar conned impinging-jet reactor (CIJR) and the multi-inlet vortex reactor (MIVR), is therefore investigated by means of numerical simulations as well as experimental flow visualization methods. In …

    iastate Repository record for Experimental and computational investigation of turbulent mixing in microscale reactors (opens in a new tab)

  8. Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices

    A stacked microchannel heat sink was developed to provide efficient cooling for microelectronics devices at a relatively low pressure drop while maintaining chip temperature uniformity. Microfabrication techniques were employed to fabricate the stacked microchannel structure, and experiments were …

    gatech Repository record for Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices (opens in a new tab)

  9. The Kinematics and Aerodynamics of Freely Flying Tiny Insects

    … the data. First, we describe a novel brightfield micro-PIV methodology to enhance the signal-to-noise ratio of the first measurements of a freely flying tiny insect. Second, we conduct an in-depth experimental analysis of tiny insects to quantify and describe relevant vortex interactions. Third, …

    usf Repository record for The Kinematics and Aerodynamics of Freely Flying Tiny Insects (opens in a new tab)

  10. Projeto, fabricação e ensaio de dispositivo microfluídico para separação de células sanguíneas baseado no efeito Zweifach-Fung

    … and contribute to a low-cost manufacture of cell microsseparation based on the bifurcation law (or Zweifach-Fung Effect). The molds of the devices were manufactured in acrylic without the necessity of a clean-room and the microsseparations were molded in two different polymers: Urethane-Acriltato …

    brazil-uerj Repository record for Projeto, fabricação e ensaio de dispositivo microfluídico para separação de células sanguíneas baseado no efeito Zweifach-Fung (opens in a new tab)

  11. The effect of stochastic nano-scale surface roughness on microfluidic flow in computational microchannels

    <p>Microfluidics is a promising technology that is used extensively in biomedical devices, so called lab-on-a-chip devices. These devices harness a network of microchannels to mix, react, and conduct fluid flow. Most microchannel fabrication methods produce a stochastic surface roughness with …

    iastate Repository record for The effect of stochastic nano-scale surface roughness on microfluidic flow in computational microchannels (opens in a new tab)

  12. Development of a microfluidic model system to study the response of endothelial cells to pulsatile shear

    … The aims of this thesis were to develop a microfluidic chip to mimic the embryonic heart and circulation and examine the response of endothelial cell to pulsatile shear flow. The chip was manufactured in PDMS consisting of a peristaltic pump with pneumatic actuated microvalves and …

    unsw Repository record for Development of a microfluidic model system to study the response of endothelial cells to pulsatile shear (opens in a new tab)

  13. Advanced optical diagnostic techniques for heat transfer measurments in supercritical CO2 flows

    … Fluorescence) for temperature measurement, and PIV ( Particle Image Velocimetry) for measurement of the velocity flow field. Different experimental setups have been built to apply the advanced optical technique. The Schlieren imaging has been used to capture the density gradient of the methane …

    ucf Repository record for Advanced optical diagnostic techniques for heat transfer measurments in supercritical CO2 flows (opens in a new tab)

  14. Microscopic Light Field Particle Image Velocimetry

    … system that combines the concepts of light field microscopy and particle image velocimetry (PIV) to measure three-dimensional velocities within a microvolume. Rectanglar microchannels were fabricated with dimensions on the order of 350-950 micrometers using a photolithographic process and …

    byu Repository record for Microscopic Light Field Particle Image Velocimetry (opens in a new tab) Download PDF for Microscopic Light Field Particle Image Velocimetry (opens in a new tab)

  15. Experimental Investigation of Micro-Channel Blockage Phenomena

    … and a study of fluid and particle motion within micro-channels having a variety of cross-sectional geometries have been conducted over a wide range of flow conditions. A micro-channel can be blocked by particles in dilute particle-laden fluid, if they have a relatively high particle-to-channel …

    uiuc Repository record for Experimental Investigation of Micro-Channel Blockage Phenomena (opens in a new tab)

  16. μ-PIV Study of the Effect of Surfactant Concentration On the Internal Flow Fields Inside a Moving Droplet

    Droplet microfluidics has enormous potential in scientific research as well as in industrial and medical applications. Droplet microfluidics enables the generation of segments in the form of discrete fluid packets. These liquid segments are mono dispersed in a continuous phase and have wide range …

    waterloo Repository record for μ-PIV Study of the Effect of Surfactant Concentration On the Internal Flow Fields Inside a Moving Droplet (opens in a new tab)

  17. AN EXPERIMENTAL INVESTIGATION ON SOLUTE NATURAL CONVECTION IN A VERTICAL HELE-SHAW CELL

    … of experimental measurement techniques in microfluidic systems, more specifically in a thin-gap device that is used as a model for a saturated porous medium. Initially, quantitative in-plane velocity measurement by means of particle image velocimetry (PIV) within thin gap devices subject to …

    maryland Repository record for AN EXPERIMENTAL INVESTIGATION ON SOLUTE NATURAL CONVECTION IN A VERTICAL HELE-SHAW CELL (opens in a new tab)

  18. Micro-particle image velocimetry for lymphatic flow

    … a reduced spatial resolution.The time-resolved micro-Particle Image Velocimetry technique, a well established method has been employed to study this transient flow. To that end, a bespoke light source was developed, utilising high-power light-emitting diodes, as well as associated control and …

    strathclyde Repository record for Micro-particle image velocimetry for lymphatic flow (opens in a new tab)

  19. Surface acoustic wave streaming in a PDMS microfluidic system: effect of frequency and fluid geometry & A remote ultrasonic glucose sensor

    … of surface acoustic wave streaming in microfluidics. The second is the development of a novel acoustic glucose sensor. A separate abstract is given for each here. Optimization of acoustic streaming in microfluidic channels by SAWs Surface Acoustic Waves, (SAWs) actuated on flat …

    glasgow Download PDF for Surface acoustic wave streaming in a PDMS microfluidic system: effect of frequency and fluid geometry & A remote ultrasonic glucose sensor (opens in a new tab)

Page 1 of 2