  1. Grain size effects in micro-tensile testing of austenitic stainless steel

    A micro-tensile test system is under development at the National Institute for Standards and Technology (NIST) and is based on tensile test techniques developed for thin films, but it provides the capability of testing samples from bulk material. Example specimen dimensions are a gage section …

    colo-mines Repository record for Grain size effects in micro-tensile testing of austenitic stainless steel (opens in a new tab)

  2. Development of a Gripping Fixture for Micro-Tensile Testing of Bonded Ceramic Dumbbells

    … and the mismatch of elastic moduli influence the tensile strengths of dental bonds attaching restorative ceramics to dentin. Prior calculations indicate this to be due to peripheral interface stress singularities. A physical testing approach to examine and validate the theoretical conclusions …

    buffalo Repository record for Development of a Gripping Fixture for Micro-Tensile Testing of Bonded Ceramic Dumbbells (opens in a new tab)

  3. Micro-Tensile bond strength of four luting resins to human enamel and dentin

    The current study aimed to investigate the influence of pulpal pressure (PP) and thermal cycling (TC) as a form of artificial aging on the bonding durability of one-step, two-step and a three-step adhesive luting systems. Dentinal surfaces were created by removing the occlusal enamel and a pulpal …

    cau-kiel Repository record for Micro-Tensile bond strength of four luting resins to human enamel and dentin (opens in a new tab)

  4. Relationship of some coniferous wood strength properties to specific gravity variations within growth increments

    Tensile and compression strength properties of six coniferous woods were studied at the tissue level. Relationships of these properties to specific gravity variations in three adjacent growth increments of each species were explored. Pacific yew was excluded from tensile strength analyses, since …

    ubc Repository record for Relationship of some coniferous wood strength properties to specific gravity variations within growth increments (opens in a new tab) Download PDF for Relationship of some coniferous wood strength properties to specific gravity variations within growth increments (opens in a new tab)

  5. On the Micro-Mechanical Property Characterization and Bulk-Volume Behavior Prediction of Additively Manufactured 17-4 PH Stainless Steels

    … cycle fatigue regime and propose a novel micro-mechanical based modeling using statistical and representative volume element. The first phase of this project examined the mechanical behavior of selective laser melting 17-4 PH stainless steel at macro-scale by tensile test and ultra-low …

    arkansas Repository record for On the Micro-Mechanical Property Characterization and Bulk-Volume Behavior Prediction of Additively Manufactured 17-4 PH Stainless Steels (opens in a new tab)

  6. Effect of silica fillers on bonding performance of 5th generation dental adhesive

    … water contact angle, degree of conversion and micro-tensile bonding strength. The longevity of the adhesive bonding strength was also studied through aging test. From this study, adhesive with Filler 2 produced the highest initial micro-tensile bonding strength, while adhesives with Filler 3 …

    missouri Repository record for Effect of silica fillers on bonding performance of 5th generation dental adhesive (opens in a new tab)

  7. Evaluation of the Biocompatibility and Micromechanical Properties of Experimental Dental Adhesives

    … was to investigate the biocompatibility and micromechanical properties of newly synthesized antibacterial monomer and cross-linker functional surfactants into a commercially available dental adhesive (Single Bond, 3M ESPE, Saint Paul, MN, USA) at three concentrations (0.05, 0.1, 0.25 mg/mg). …

    buff-state Repository record for Evaluation of the Biocompatibility and Micromechanical Properties of Experimental Dental Adhesives (opens in a new tab)

  8. Process variation effects linked to feature size on fatigue performance in additively manufactured 316L stainless steel

    … such as poor surface quality, defects, microstructure inhomogeneity, and material anisotropy limit its application. The influence of part geometry size and scale on crystallographic and porosity microstructural features, crucial in early-stage fatigue crack initiation, necessitates a …

    soton Download PDF for Process variation effects linked to feature size on fatigue performance in additively manufactured 316L stainless steel (opens in a new tab)

  9. Mechanical properties and shear bond strength of denture teeth to different denture base materials

    … and fracture toughness testing (8 × 4 × 39 mm3). Tensile strength specimens were fabricated to form dumbbell-shaped specimens (3 × 6 mm cross-section) with a central bar. Micro-tensile specimens were fabricated into 10 × (1.5 ± 0.2) × (1.5 ± 0.2) mm3 bars. The treated specimens were subjected to …

    bu Repository record for Mechanical properties and shear bond strength of denture teeth to different denture base materials (opens in a new tab)

  10. Short- and Long-Term Dentin Bond Strength of Bioactive Glass-Modified Dental Adhesives

    … From each tooth, 14 sticks were prepared for micro-tensile bond strength (µTBS) testing. The sticks were stored in simulated body fluid at 37 °C and tested after 24 h or six months for µTBS and failure mode. Data were analyzed using Kruskal–Wallis tests in combination with post-hoc …

    zurich Restricted access

  11. Multiscale experimental and computational studies of mechanical properties in ion irradiated nuclear structural materials

    … Small scale experimental techniques, such as micro-tensile testing and nanoindentation, allow for the analysis of the shallow irradiation zones. A significant challenge to these techniques is the presence of gradient plasticity phenomena, that is most pronounced at these very shallow depths. …

    unsw Repository record for Multiscale experimental and computational studies of mechanical properties in ion irradiated nuclear structural materials (opens in a new tab)

  12. In-vitro assessment of modified resin adhesive-tooth interfaces

    … activity and substrate zymography, respectively. Micro-tensile bond strength and micro-permeability were used to evaluate the modified adhesives’ physical properties. Micro-Raman spectroscopy analysis was validated on carious dentine and it was used to evaluate the interface between the modified …

    kings Repository record for In-vitro assessment of modified resin adhesive-tooth interfaces (opens in a new tab) Download PDF for In-vitro assessment of modified resin adhesive-tooth interfaces (opens in a new tab)

  13. Improving bonding strength of mild self-etching adhesive to ground and intact enamel by plasma treatment

    … strength increased significantly (p<0.01) after micro-tensile bonding strength test; the water contact angle and adhesive contact angle on enamel surface decreased a lot (p<0.05). Weibull analysis revealed that Weibull modulus for plasma-treated specimens was increased. SEM examination of the …

    missouri Repository record for Improving bonding strength of mild self-etching adhesive to ground and intact enamel by plasma treatment (opens in a new tab)

  14. Development of a novel cell traction force transducer based on cholesteryl ester liquid crystals. Characterisation, quantification and evaluation of a cholesteryl ester liquid crystal based single cell force transducer system.

    … (LLC) were characterised by using polarising microscopy, rheology, atomic force microscopy (AFM) based nano-indentation, spherical indentation, and micro-tensile tests. The interactions of LLC with cells were studied by using cell viability studies, cytochemical treatments, widefield surface …

    bradford Repository record for Development of a novel cell traction force transducer based on cholesteryl ester liquid crystals. Characterisation, quantification and evaluation of a cholesteryl ester liquid crystal based single cell force transducer system. (opens in a new tab)

  15. Microstructural Investigation of the Influence of Geometry on the Mechanical Reliability of Additively Manufactured Metals

    … demonstrates the wide range of macro- and micro- characterization techniques used to investigate several precipitation strengthened AM alloy systems. While AM allows for nearly unlimited design freedom, this brings along its own issues as the interplay between scan strategy and part …

    uky-thes Repository record for Microstructural Investigation of the Influence of Geometry on the Mechanical Reliability of Additively Manufactured Metals (opens in a new tab)

  16. Large-scale fabrication of SiC nanofibers and plasma interface engineering of polymer nanocomposites and dental composite restoration

    … the SiC nanofiber growth as observed in electron microscopy. Allylamine plasma surface treated MWNTs and SiC nanofibers enhanced dispersion and interfacial adhesion in an epoxy matrix. All composite samples without plasma treatment lowered in tensile strength, but after plasma treatment all …

    missouri Repository record for Large-scale fabrication of SiC nanofibers and plasma interface engineering of polymer nanocomposites and dental composite restoration (opens in a new tab)

  17. Micro-mechanical investigations of irradiation tolerance in nanostructured ferritic alloys processed into thin-walled tubing

    … this work investigates the properties and microstructure of those materials using high-throughput micro-mechanical techniques before and after ion irradiation. Specifically, this work shows the use of sharp indentation, spherical nanoindentation, micro-pillar compression, and micro-tensile …

    unr Repository record for Micro-mechanical investigations of irradiation tolerance in nanostructured ferritic alloys processed into thin-walled tubing (opens in a new tab)

  18. The Effects of Laser Etching on Biocompatability and Mechanical Properties of Polyetheretherketone

    … of implantable PEEK by measuring contact angle, micro-tensile testing, nite-element modeling (FEM), and biocompatibility testing according to International Organization for Standardization (ISO) 10993 for cytotoxicity. The results of the study showed that the etching characteristics were mostly …

    utahstate Repository record for The Effects of Laser Etching on Biocompatability and Mechanical Properties of Polyetheretherketone (opens in a new tab)