Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"Micro-arc oxidation"”

  1. Electrochemical behaviors of micro-arc oxidation coated magnesium alloy

    … surface. Most coating methods, such as anodic oxidation, polymer coating and chemical conversion coating, cannot produce satisfactory coating to be used in human body environment. Recent studies demonstrate that micro-arc oxidation (MAO) technique can produce hard, dense, wear-resistant and …

    iupui Repository record for Electrochemical behaviors of micro-arc oxidation coated magnesium alloy (opens in a new tab)

  2. Enhance its Corrosion Behavior of Additively Manufactured NiTi by Micro-Arc Oxidation Coating

    … is coating. Among all the coating methods, micro-arc oxidation coating has interesting characteristics that allow depositing a desired structure and chemical combination of elements on the surface. This work has focused on the type and combination of electrolyte along with the voltage and …

    ohiolink Repository record for Enhance its Corrosion Behavior of Additively Manufactured NiTi by Micro-Arc Oxidation Coating (opens in a new tab)

  3. Growth and Characterization of Magnesium Single Crystal for Biodegradable Implant Material Application

    … coupled plasma mass spectroscopy (ICPMS) and Micro computed tomography or "micro-CT" techniques. Attempts to improve the corrosion behavior of the substrate has been made via utilizing various surface treatments such as DC anodization, micro arc oxidation (MAO) and chemical etching. <i>In …

    ohiolink Repository record for Growth and Characterization of Magnesium Single Crystal for Biodegradable Implant Material Application (opens in a new tab)

  4. Biofunctionalization of titanium surfaces for dental implants: osteogenic, anti-microbial and tribocorrosion resistant surfaces

    … and inhibit the colonization by unwanted microorganisms. Furthermore, it is also necessary to minimize combined actions between corrosion and wear (tribocorrosion) that can cause degradation of the implant surface and ultimately lead to its failure. This thesis presents an approach to …

    minho-thes Repository record for Biofunctionalization of titanium surfaces for dental implants: osteogenic, anti-microbial and tribocorrosion resistant surfaces (opens in a new tab)

  5. Bioresorbable Magnesium-Based Bone Fixation Hardware: Alloy Design, Post-Fabrication Heat Treatment, Coating, and Modeling

    … corrosion properties. The main goal of this research is to develop bioresorbable Mg-based fixation hardware with adequate strength and acceptable degradation rate using nontoxic alloying elements. To this end, finite element analysis, design of experiments, and novel post-fabrication techniques …

    ohiolink Repository record for Bioresorbable Magnesium-Based Bone Fixation Hardware: Alloy Design, Post-Fabrication Heat Treatment, Coating, and Modeling (opens in a new tab)

  6. On the bone response to oxidized titanium implants. The role of microporous structure and chemical composition of the surface oxide in enhanced osseointegration

    … aims of this thesis were (i) to develop anodic oxidation methods of titanium implants (paper 1), (ii) to characterize the surface properties of native and anodic oxides (paper 2) and (iii) to investigate if and which surface oxide properties will influence the bone tissue response. In vivo …

    goteborg Repository record for On the bone response to oxidized titanium implants. The role of microporous structure and chemical composition of the surface oxide in enhanced osseointegration (opens in a new tab)

  7. Development of quantitative techniques for the study of discharge events during plasma electrolytic oxidation processes

    Plasma electrolytic oxidation, or PEO, is a surface modification process for the production of ceramic oxide coatings upon substrates of metals such as aluminium, magnesium and titanium. Two methodologies for the quantitative study of electrical breakdown (discharge) events observed during plasma …

    cambridge Repository record for Development of quantitative techniques for the study of discharge events during plasma electrolytic oxidation processes (opens in a new tab)

  8. On the Bone Tissue Response to Surface Chemistry Modifications of Titanium Implants

    … ion implantation and deposition (PIIID) and micro arc oxidation (MAO). Using these techniques, Mg-, Ca- and O-incorporated titanium surfaces were prepared. Surface chemistry was analyzed by X-ray photoelectron spectroscopy and auger electron spectroscopy. For topographical analyses, we used …

    goteborg Repository record for On the Bone Tissue Response to Surface Chemistry Modifications of Titanium Implants (opens in a new tab)

  9. Phenomena Associated with Individual Discharges during Plasma Electrolytic Oxidation

    … (discharge) events during plasma electrolytic oxidation (PEO) of aluminium alloy substrates. Discharges were found to occur in extended sequences termed “cascades” at particular locations. This was a feature common to all the substrates and processing frequencies investigated. As the coating …

    cambridge Repository record for Phenomena Associated with Individual Discharges during Plasma Electrolytic Oxidation (opens in a new tab)

  10. Etude des mécanismes d'incorporation et du devenir de particules d'argent dans des couches d'oxydes d'aluminium formées par oxydation micro-arcs

    … de surface sont essentiels. L'Oxydation Micro-Arc (OMA) est un procédé permettant de former une couche d'oxydes permettant d'améliorer la résistance à la corrosion et à l'usure. Pour certaines applications, il est intéressant d'ajouter des particules dans la couche d'oxydes afin de …

    star-france Repository record for Etude des mécanismes d'incorporation et du devenir de particules d'argent dans des couches d'oxydes d'aluminium formées par oxydation micro-arcs (opens in a new tab)

  11. Oxydation par plasma électrolytique : influence des paramètres du procédé sur le comportement des micro-décharges et conséquences sur les couches d’oxydes

    … par plasma électrolytique (ou oxydation micro-arc) est un procédé de traitement des alliages légers (Al, Mg, V, Ti, etc.) apte à pallier les limites de l’anodisation, en particulier au regard des contraintes environnementales. Bien que connu depuis de nombreuses années, les mécanismes …

    star-france Repository record for Oxydation par plasma électrolytique : influence des paramètres du procédé sur le comportement des micro-décharges et conséquences sur les couches d’oxydes (opens in a new tab)