Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Micro-channel plate"”

  1. Investigation of a resistive anode detector for astronomical spectroscopy

    … computer operating under FORTH control. The micro-channel plate operating characteristics and the detector's resolution, quantum efficiency and imaging performance have been studied. The principal areas requiring design improvement are found to be the micro-channel plate gain, processing and …

    st-andrews Repository record for Investigation of a resistive anode detector for astronomical spectroscopy (opens in a new tab)

  2. DIFFERENTIAL CROSS SECTIONS FOR NEUTRAL-NEUTRAL COLLISIONS

    … A new technique, based on the use of a micro-channel plate position-sensitive detector, has been developed for studying some of these collision processes. Differential cross sections have been measured over a primary beam energy range of 500eV to 5000eV for the scattering of atomic …

    rice Repository record for DIFFERENTIAL CROSS SECTIONS FOR NEUTRAL-NEUTRAL COLLISIONS (opens in a new tab)

  3. High Depth Resolution Rutherford Backscattering Spectrometry with a Magnet Spectrometer: Implementation and Application to Thin Film Analysis

    … which consists of a spectrometer magnet and a Micro-Channel Plate - Focal Plane Detector (MCP-FPD) assembly. In this thesis, analytical and numerical studies of the spectrometer ion optics were conducted and their results compared to the actual magnet response to ensure the accuracy and quality …

    nus Repository record for High Depth Resolution Rutherford Backscattering Spectrometry with a Magnet Spectrometer: Implementation and Application to Thin Film Analysis (opens in a new tab)

  4. First observations of Rydberg blockade in a frozen gas of divalent atoms

    … The remaining ions that are recorded on a micro-channel plate are proportional to the number of Rydberg atoms. The development of a narrow linewidth laser system necessary for an additional stage of cooling is explained and characterised. Two frequency stabilisation schemes are discussed: …

    durham Repository record for First observations of Rydberg blockade in a frozen gas of divalent atoms (opens in a new tab)

  5. Excited state spatial distributions in a cold strontium gas

    … timescales, with the ions recorded on a micro-channel plate being proportional to the amount of Rydberg atoms. Translation of an autoionizing laser focused to a waist of 10 μm gives a spatially resolved Rydberg signal. A two-dimensional map of the Rydberg spatial distribution has been …

    durham Repository record for Excited state spatial distributions in a cold strontium gas (opens in a new tab)

  6. HIGHLY-CHARGED IONS ISOLATED IN UNITARY PENNING TRAPS FOR PRECISION MEASUREMENTS

    … via position-sensitive or time-of-flight micro-channel plate (MCP) detectors. As a first demonstration, Ar<super>13+</super> ions are captured in one of the two fine structure levels forming the lowest lying states. The lifetime of the metastable 1s<super>2</super>2s<super>2</super>2p …

    maryland Repository record for HIGHLY-CHARGED IONS ISOLATED IN UNITARY PENNING TRAPS FOR PRECISION MEASUREMENTS (opens in a new tab)

  7. A high-speed mass spectrometer for characterizing flash desorbed species in pulsed power applications

    … rate over that of the ammeter, (3) incorporate a micro-channel plate within the probe to amplify the current feed to the TIA and enable even faster data sampling rates, and (4) design a high speed electric shutter to quickly turn "on" and "off" ion flow to the probe to enable measurement of the …

    colostate Repository record for A high-speed mass spectrometer for characterizing flash desorbed species in pulsed power applications (opens in a new tab)

  8. ROCKET-BORNE LOW ENERGY ION MEASUREMENTS IN SPACE

    … rocket platforms. This instrument employs micro channel plate detectors in conjunction with a linear resistive anode to carry out angular imaging, by resistive charge division, of particle arrivals. Two such instruments, capable of supplying 64 x 32 angle-energy positive ion distributions …

    unh-thes Repository record for ROCKET-BORNE LOW ENERGY ION MEASUREMENTS IN SPACE (opens in a new tab)

  9. Nuclear motion in molecular ions studied with synchrotron radiation and multicoincidence momentum imaging spectrometry

    … be extracted. The apparatus is equipped with a micro-channel-plate detector opposite to the delay line anode, enabling electron-ion coincidence experiments and thereby mass-resolved ion spectroscopy independent of the time structure of the synchrotron radiation. Calibration and characterization …

    lund Repository record for Nuclear motion in molecular ions studied with synchrotron radiation and multicoincidence momentum imaging spectrometry (opens in a new tab)

  10. Extreme Ultraviolet Spectral Streak Camera

    … CCDs are limited to temporal resolution in the microsecond range. This work shows a novel approach to imaging EUV light over a nanosecond time scale, by using an EUV scintillator to convert EUV to visible light imaged by a conventional streak camera. A laser produced plasma, using a mass-limited …

    ucf Repository record for Extreme Ultraviolet Spectral Streak Camera (opens in a new tab)

  11. Numerical study of ionospheric response to perturbations and interaction with spacecraft instruments

    … are used to compute ion fluxes on the SII micro channel plate (MCP) and computed fluxes are compared with JOULEII measurements.

    alberta Repository record for Numerical study of ionospheric response to perturbations and interaction with spacecraft instruments (opens in a new tab)

  12. A 3.0 meter liquid mirror telescope

    … a field of 46 arcminute diameter. Utilizing Micro-Channel-Plate (MCP) intensified video cameras we have obtained 750 hours of zenith staring orbital object event data with a limiting object diameter of approximately 1 cm at 1000 km altitude and 0.1 albedo. We have extended to 17.75 the lower …

    rice Repository record for A 3.0 meter liquid mirror telescope (opens in a new tab)

  13. A Study of the Secondary Electrons

    … signal source for SEM and for other advanced microanalysis techniques. SE yield δ and spectrum N(E) are the two important parameters evaluating the capability of a sample on producing SEs and the energy distribution of SEs generated from the sample respectively. Measuring δ and N(E) is not …

    utk-theses Repository record for A Study of the Secondary Electrons (opens in a new tab)

  14. Study of a prototype module of a precision time-of-flight detector for particle identification at low momentum

    … by the charged particle in a 1 cm-thick quartz plate. In order to calculate accurately the flight time in a busy LHCb environment, Cherenkov angle and photon detection time information, as well as the momentum information from the tracking detector are included in the analysis. For the required …

    epfl Repository record for Study of a prototype module of a precision time-of-flight detector for particle identification at low momentum (opens in a new tab)

  15. Development of a multi-laser, multi-channel XUV spectrometer facility based on the dual laser plasma technique

    … reported in this thesis, a multi-laser, multi-channel spectrometer facility, for the measurement of photoionization cross sections of free atoms, excited atoms and ions, in the XUV has been developed. The facility is based on the DLP (Dual Laser Plasma) technique, whereby the absorbing column …

    dcu Repository record for Development of a multi-laser, multi-channel XUV spectrometer facility based on the dual laser plasma technique (opens in a new tab)

  16. Leveraging Microscience to Manipulate Laser-Plasma Interactions at Relativistic Intensities

    … ultra-short pulse laser incident on a hollow, micron-scale, cylindrical structure we have termed the Micro-tube Plasma (MTP) lens. The computational studies, performed using three-dimensional particle-in-cell (PIC) simulations, show that Fresnel diffraction and plasma guiding from the …

    ohiolink Repository record for Leveraging Microscience to Manipulate Laser-Plasma Interactions at Relativistic Intensities (opens in a new tab)

  17. Short wavelength lasers and their applications

    … of the target material, laser focusing, and micro-channel-plate (MCP) focusing of the plasma emission, an output of between 10<sup>6</sup> and 10<sup>7</sup> photons per shot in a 4 nm bandwidth could be delivered on target.</p>

    oxford Repository record for Short wavelength lasers and their applications (opens in a new tab)

  18. Beta-decay, beta-delayed neutron emission and isomer studies around <sup>78</sup>Ni

    … development of a detector system using a dual micro channel plate configuration. The system was built to detect and measure nanosecond isomers in neutron rich <sup>73-76</sup>Cu and <sup>76</sup>Zn isotopes. The design of the instrument and preliminary beam and alpha source tests done on the …

    utk-theses Repository record for Beta-decay, beta-delayed neutron emission and isomer studies around <sup>78</sup>Ni (opens in a new tab)

  19. Development of Large-Area MCP-PMT Photo-Detectors for a Precision Time-of-Flight System at the Fermilab Test Beam Facility

    A system of Large Area Picosecond Photodetectors (LAPPD^TM) has been constructed at the Fermilab Test Beam Facility (FTBF) to measure charged particles in a time-of-flight configuration. Cherenkov photons produced by charged particles passing through the glass window induce signals that mark the …

    chicago Repository record for Development of Large-Area MCP-PMT Photo-Detectors for a Precision Time-of-Flight System at the Fermilab Test Beam Facility (opens in a new tab)