  1. Kinematic, dynamics, and control of a particular micro-motion system

    … a need for devices which can perform very small motions (less than 100 μm) with very high positioning accuracy (in the submicron range) and complex trajectories. This range of motion is known as micro-motion. In this thesis, the research is described concerning the design of micro-motion systems. …

    sask Repository record for Kinematic, dynamics, and control of a particular micro-motion system (opens in a new tab)

  2. Design of 3-DOF parallel manipulators for micro-motion applications

    This thesis presents two unique micro-motion parallel kinematic manipulators (PKM): a three degrees of freedom (3-DOF) micro-motion manipulator and a 3-DOF micro-motion manipulator with actuation redundancy. The 3-DOF micro-motion manipulator has three linear-motion driving units, and the 3-DOF …

    uoit Repository record for Design of 3-DOF parallel manipulators for micro-motion applications (opens in a new tab)

  3. Kinetostatic modelling of compliant micro-motion stages with circular flexure hinges.

    … methodology of deriving kinetostatic models of micro-motion stages by incorporating the scheme mentioned above. There were various flexure hinge equations previously derived using different methods to predict the compliances of circular flexure hinges. However, some of the analytical/empirical …

    adelaide Repository record for Kinetostatic modelling of compliant micro-motion stages with circular flexure hinges. (opens in a new tab)

  4. Micro-motion detection by optical coherence tomography (OCT) and its clinical applications

    Ddetection of micro-motion on biological tissues has various applications such as ultrasound elastography and magnetic resonance elastography (MRE). Ultrasound transducers, the most commonly used tool to detect endogenous and exogenous micro-motions, have a number of drawbacks: including the …

    dundee Repository record for Micro-motion detection by optical coherence tomography (OCT) and its clinical applications (opens in a new tab)

  5. The modelling and optimal design of a three degree-of-freedom XYθz micro-motion stage

    … of a particular 3-degree-of-freedom (DOF) XYθz micro-motion stage. This stage provides micron-scale motion in X and Y directions and a rotation about the Z-axis. Such a stage can be used for applications where positioning of components with micrometre, or even nanometre positioning accuracy is …

    adelaide Repository record for The modelling and optimal design of a three degree-of-freedom XYθz micro-motion stage (opens in a new tab)

  6. Advanced maritime target recognition from SAR images exploiting target’s micro-motions and AI

    … to target classification, co-registration, and micro-motion analysis, in the field of maritime surveillance. SAR technology offers unique advantages in maritime environments, including the ability to operate under diverse weather and lighting conditions. This research aims to exploit these …

    strathclyde Repository record for Advanced maritime target recognition from SAR images exploiting target’s micro-motions and AI (opens in a new tab)

  7. Corrosion and Fretting Corrosion Studies of medical grade CoCrMo implant material in a more clinically relevant simulated body environment.

    In modular hip implants, micro-motion, which leads to fretting corrosion at the head/neck and neck/stem interfaces, has been identified as a major cause of early revision in hip implants, particularly those with heads larger than 32mm. It has been found that the type of fluid used to simulate the …

    manitoba Repository record for Corrosion and Fretting Corrosion Studies of medical grade CoCrMo implant material in a more clinically relevant simulated body environment. (opens in a new tab)

  8. FUNCTIONAL BIOMECHANICAL EVALUATION OF MULTIPLE DESIGN PROGRESSIONS OF DISTAL RADIUS VOLAR PLATES

    … those generated during the early active motion of the wrist and digits were applied. The structural stiffness of the construct, stiffness across the created fracture gap and fracture gap micro motion of all the constructs were measured and compared to assess the relative stability of …

    ohiolink Repository record for FUNCTIONAL BIOMECHANICAL EVALUATION OF MULTIPLE DESIGN PROGRESSIONS OF DISTAL RADIUS VOLAR PLATES (opens in a new tab)

  9. An Investigation into the Effect of Modular Taper Design in Total Hip Replacements on Engagement, Motion and Fretting Corrosion

    … are susceptible to fretting corrosion due to micro-scale motions in a corrosive environment that presents a crevice geometry, referred to in the field as mechanically assisted crevice corrosion. Mechanically assisted crevice corrosion or fretting corrosion has been, and continues to be, …

    whiterose Repository record for An Investigation into the Effect of Modular Taper Design in Total Hip Replacements on Engagement, Motion and Fretting Corrosion (opens in a new tab)

  10. Affordable flexible hybrid manipulator for miniaturised product assembly

    … millimetres in size with an accuracy of a few micrometres. Reducing the size and the cost of such a system while increasing its flexibility and accuracy is a challenging issue. The introduction of hybrid manipulation, also called coarse/fine manipulation, within an assembly system is the …

    heriot-watt Repository record for Affordable flexible hybrid manipulator for miniaturised product assembly (opens in a new tab)

  11. Radar and wireless channel state information for non-contact and continuous physiological monitoring

    … challenging because cardiac and respiratory micro-motions are extremely small and easily corrupted by hardware imperfections, motion artifacts, respiration harmonics, and subject-dependent thoracoabdominal biomechanics. This dissertation advances contactless health sensing by presenting: (i) …

    hawaii Repository record for Radar and wireless channel state information for non-contact and continuous physiological monitoring (opens in a new tab) Embargoed until 2028-10-07

  12. Ion Photon Entanglement in a Parabolic Mirror Trap

    … that the optical resolution is limited by ion micro-motion. When trapping singly ionized barium, entanglement can be established between its energy level and the polarization of fluorescence. This setup generates an entangled ion-photon pair at 1 Hz with a mode-locked pulsed laser as the …

    washington Repository record for Ion Photon Entanglement in a Parabolic Mirror Trap (opens in a new tab)

  13. On a finite element approach to modeling of piezoelectric element driven compliant mechanisms

    Micro-motion devices may share a common architecture such that they have a main body of compliant material and some direct actuation elements (e.g., piezoelectric element). The shape of such a compliant material is designed with notches and holes on it, and in this way one portion of the material …

    sask Repository record for On a finite element approach to modeling of piezoelectric element driven compliant mechanisms (opens in a new tab)

  14. Non-Visual Human Eye Gaze Tracking Using Radar and Artificial Intelligence for Robust Driver Monitoring Systems

    … GHz has demonstrated sensitivity to eye-region micro-motion such as blinks. Whether radar can support directional gaze estimation, rather than binary event detection, remains an open question. This thesis develops a radar-only gaze estimation pipeline built on a 60 GHz FMCW sensor. Amplitude and …

    chalmers Repository record for Non-Visual Human Eye Gaze Tracking Using Radar and Artificial Intelligence for Robust Driver Monitoring Systems (opens in a new tab)

  15. CONNESSIONI IMPIANTO-ABUTMENT VALUTAZIONE DEL RIASSORBIMENTO OSSEO PERIMPLANTARE IN DUE SISTEMATICHE A CONFRONTO

    … difference P < 0,0001. We assume that micro-gap, micro-motion and stress distribution at the connections of implants, as well as the biological width at the implant surface and the microbiological enviroment at the implant sulcus work all together sinergically and impair the result. …

    milano Repository record for CONNESSIONI IMPIANTO-ABUTMENT VALUTAZIONE DEL RIASSORBIMENTO OSSEO PERIMPLANTARE IN DUE SISTEMATICHE A CONFRONTO (opens in a new tab) Restricted access

  16. The Effect of Surface and Loading Conditions on the Corrosion Performance of Stainless Steel Rebar

    … when subjected to dynamic loading due to micro-motion at the concrete/crack interface. It was concluded that as-rolled stainless steel rebar in aggressive environments would provide sufficient corrosion resistance for the 75 year lifespan currently specified by the Canadian Bridge Code …

    waterloo Repository record for The Effect of Surface and Loading Conditions on the Corrosion Performance of Stainless Steel Rebar (opens in a new tab)

  17. A Novel Fluid Structure Interaction and Thermal Model to Predict the Cylinder Block / Valve Plate Interface Performance in Swash Plate Type Axial Piston Machines

    … squeeze film effect due to the cylinder block's micro-motion and the change in fluid film thickness due to the elastic deformations of the solid parts, caused by the fluid film pressure and by the thermal strains. In addition, the impact of micro-surface shaping introduced by design or resulting …

    purdue-thes Repository record for A Novel Fluid Structure Interaction and Thermal Model to Predict the Cylinder Block / Valve Plate Interface Performance in Swash Plate Type Axial Piston Machines (opens in a new tab)

  18. Polyampholyte Hydrogel Characteristics and Detecting the Bacterial Interactions With These Hydrogels Using Digital Image Processing Methods

    … these techniques. Comparative change in the micro motion of the bacteria over balanced polyampholyte hydrogels and the unbalanced polyelectrolyte hydrogels were also presented. The cumulative result of this thesis is that the selection of the acidic and basic monomers used in the preparation …

    ut-knoxville Repository record for Polyampholyte Hydrogel Characteristics and Detecting the Bacterial Interactions With These Hydrogels Using Digital Image Processing Methods (opens in a new tab)

  19. Torques in total hip replacements

    … to affect component fixation and/or induce micro motion linked to fretting and corrosion at modular junctions. Pre-clinical testing of friction behaviour in THRs has predominantly been assessed under simplified test conditions using uniaxial simulators. These methodologies and simulators are …

    whiterose Repository record for Torques in total hip replacements (opens in a new tab)