Showing 1 to 20 of 26 for “"MicroCT imaging"”.

  1. Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy

    Motivated by the need to standardize preclinical imaging for image-guided radiation therapy (IGRT), we examine the parameters that influence microcomputed tomography (microCT) scans in the realm of image quality and absorbed dose to tissue, including therapy beam measurements of small fields. …

    uvic Repository record for Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy (opens in a new tab)

  2. Non-invasive prediction of bone mechanical properties of the mouse tibia in longitudinal preclinical studies

    … using in vivo micro-Computed Tomography (microCT) imaging in order to track longitudinal changes in its morphometric and densitometric properties. Additionally, microCT images can be converted into micro-Finite Element (microFE) models for the non-invasive estimation of mechanical …

    whiterose Download PDF for Non-invasive prediction of bone mechanical properties of the mouse tibia in longitudinal preclinical studies (opens in a new tab)

  3. GRAPHENE ONTO MEDICAL TITANIUM:AN ATOMIC-THICK COATING THAT PROMOTES OSTEOGENIC DIFFERENTIATION IN VITRO AND IN VIVO

    … expression of osteogenic markers than CpTi. MicroCT imaging showed effective bone regeneration on WGp and DGp than CpTi after 4 and 8 weeks. Furthermore, we provide a characterization of extracellular matrix, secreted by MG-63 cell on substrate. Finally, we report a vacuum-assisted dry …

    nus Repository record for GRAPHENE ONTO MEDICAL TITANIUM:AN ATOMIC-THICK COATING THAT PROMOTES OSTEOGENIC DIFFERENTIATION IN VITRO AND IN VIVO (opens in a new tab) Download file for GRAPHENE ONTO MEDICAL TITANIUM:AN ATOMIC-THICK COATING THAT PROMOTES OSTEOGENIC DIFFERENTIATION IN VITRO AND IN VIVO (opens in a new tab)

  4. Modulating the Release of Therapeutic Agents from PLGA Coated Cancellous Allografts

    … group compared to BMP-2 alone, with X-Ray and MicroCT imaging showing a near bony union by 8 weeks in the combined group.

    uconn-diss Repository record for Modulating the Release of Therapeutic Agents from PLGA Coated Cancellous Allografts (opens in a new tab)

  5. Elucidating the Effects of Local Nav1.8 Channel Downregulation on Osteoarthritis-Related Chronic Pain

    … behaviors for multiple weeks. Importantly, microCT imaging demonstrated preservation of subchondral bone structure in animals treated with the active peptide, in contrast to those receiving a scrambled peptide control, suggesting a potential disease-modifying effect. These findings support …

    buffalo Repository record for Elucidating the Effects of Local Nav1.8 Channel Downregulation on Osteoarthritis-Related Chronic Pain (opens in a new tab)

  6. A novel framework for assessing variations in 3D geometry of mouse tibiae in longitudinal preclinical studies

    … In vivo micro-Computed Tomography (microCT) is the standard for monitoring longitudinal bone changes. Standard morphometry applied on images provides temporal changes in scalar geometric properties. However, these properties lack precision due to their limited dimensionality and …

    whiterose Download PDF for A novel framework for assessing variations in 3D geometry of mouse tibiae in longitudinal preclinical studies (opens in a new tab)

  7. The comparative role of demineralized bone matrix placement on the periosteum versus in the muscle with and without bone morphogenetic protein 2

    … development of the bone. Analysis included X-ray imaging, microCT imaging, and mRNA expression. Plain x-ray and micro-CT imaging analysis showed mineralized bone formation in the implant on the periosteum and in the muscle with BMP-2, but no growth in the muscle when BMP-2 was not added to the …

    bu Repository record for The comparative role of demineralized bone matrix placement on the periosteum versus in the muscle with and without bone morphogenetic protein 2 (opens in a new tab)

  8. A pathway toward enamel-inspired damage-tolerant ceramics

    … several mammalian species was investigated using microCT imaging to establish a novel, quantitative description of the enamel microstructure. From this description, a printable model using filament extrusion additive manufacturing technologies was established and validated against the quantitative …

    washington Repository record for A pathway toward enamel-inspired damage-tolerant ceramics (opens in a new tab)

  9. Quantitative Histological Analysis of Fixation Points on Explanted Hernia Mesh

    … design utilizing micro computed tomography (microCT) to guide histological analysis of in vivo hernia mesh explants. Presuming that peripheral fixation points (locations near sutures or tacks) on in situ hernia mesh experience high tension during physiological loading, it was hypothesized …

    clemson Repository record for Quantitative Histological Analysis of Fixation Points on Explanted Hernia Mesh (opens in a new tab)

  10. Blood Flow Simulation in Stented Vessels and Flow Reversal Conditions

    … The first part of this work is dedicated to the imaging of stent deployment in graft tubes and ex vivo arterial segments and the investigation of in-stent hemodynamics through computational hemodynamic simulations, i.e., CHD, based on realistic in vitro stent and wall geometries. The second part …

    houston Repository record for Blood Flow Simulation in Stented Vessels and Flow Reversal Conditions (opens in a new tab)

  11. The heart-placenta axis in fetal growth restriction: How does structure impact function?

    … lead to cardiac remodelling. Indeed, novel 3D microCT imaging of Cdh5cre+Hand1A126f/s+ hearts demonstrated significant decreases in RV cavity volume, endocardial surface area and interventricular mid-septal thickness. In the gestational hypoxia model, the only significant difference in vascular …

    auckland-ms Repository record for The heart-placenta axis in fetal growth restriction: How does structure impact function? (opens in a new tab)

  12. Xylem embolism repair in the stem of intact Populus balsamifera saplings : single-scan and time-series microCT experiments

    … L. saplings using X-ray microtomography (microCT) to visualize and quantify the water- and air-filled status of xylem vessels and fibers. Two experiments were conducted: (1) a single-scan experiment comparing droughted saplings and those 7 days after rehydration, and (2) a time-series …

    ubc Repository record for Xylem embolism repair in the stem of intact Populus balsamifera saplings : single-scan and time-series microCT experiments (opens in a new tab) Download PDF for Xylem embolism repair in the stem of intact Populus balsamifera saplings : single-scan and time-series microCT experiments (opens in a new tab)

  13. Immunohistochemical and 3D analysis of the human fetal palate

    … fetal heads aged 67-84days underwent MRI and microCT with phosphotungstic acid contrast agent. Qualitative analysis of 3-dimensional shape changes during palatal development was completed using a 3D slicer program. Results: We confirm the presence of an epithelial seam extending throughout the …

    ubc Repository record for Immunohistochemical and 3D analysis of the human fetal palate (opens in a new tab) Download PDF for Immunohistochemical and 3D analysis of the human fetal palate (opens in a new tab)

  14. Form and function of snake genitalia: Hidden hemiclitores, historic hemipenes and versatile vaginas

    … species. Using dissection, contrast enhanced microCT, and histology this chapter demonstrates the morphological diversity, non-eversible form, and presence of erectile tissue and nerves within the snake hemiclitores. Collectively, this work suggests the hemiclitores structure has functional …

    adelaide Repository record for Form and function of snake genitalia: Hidden hemiclitores, historic hemipenes and versatile vaginas (opens in a new tab)

  15. Effects of Microstructure and Particle Population on Void Damage Evolution in Complex Phase Steel

    … tension testing and micro-computed tomographic (microCT) imaging of both commercially produced sheets and sheets heat treated to produce polygonal ferrite (PF) and granular bainite (GB) model microstructures. Continuous cooling transformation (CCT) diagrams illustrate the phase transformations …

    queens Repository record for Effects of Microstructure and Particle Population on Void Damage Evolution in Complex Phase Steel (opens in a new tab)

  16. Soil structure and water retention under Miscanthus × giganteus: Integrating do-it-yourself and standard lab methods

    … destroyed—indicating a structural mechanism. MicroCT imaging confirmed no differences in total porosity but revealed shifts in pore size distribution. Chapter 4 expands this analysis to three long-term miscanthus research sites across Iowa, comparing maize, miscanthus, and perennial grass …

    iastate Repository record for Soil structure and water retention under Miscanthus × giganteus: Integrating do-it-yourself and standard lab methods (opens in a new tab)

  17. Morphology of Acercaria: investigations of the ovipositor and internal anatomy

    … results here demonstrate the great potential for microCT imaging in opening and exploring novel and neglected avenues of morphological investigation."

    uiuc Repository record for Morphology of Acercaria: investigations of the ovipositor and internal anatomy (opens in a new tab)

  18. Lumbar Spine Behavior and Injury Due to Cyclic Loading

    … prior to endplate failure. Preliminary post-test microCT images from specimens loaded in repeated flexion-compression without endplate damage revealed that there may be changes in the IVD tissue prior to endplate failure due to repeated loading. Because the outer AF in healthy IVDs is innervated …

    duke Repository record for Lumbar Spine Behavior and Injury Due to Cyclic Loading (opens in a new tab)

  19. Capillary blood sampling using a jet injector

    … injection with the slot nozzle was revealed, by microCT imaging, to create a wound shape i.e., a narrow, non-cylindrical channel across the dermis, similar to that of a lancet prick. Tissue disruption and estimated blood volume resulting from skin penetration by a circular jet, a slot-shaped jet …

    auckland-ms Repository record for Capillary blood sampling using a jet injector (opens in a new tab)