Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"Microbalances"”.

  1. A study of recognition coating response for quartz crystal microbalances

    … for chemically coated Quartz Crystal Microbalances (QCMs). When exposed to the individual vapors of a homologous series of carboxylic acid vapors, a QCM coated with varying thicknesses of poly(ethylenimine) (PEI) coating, produces a linear response that is sensitive and selective. The …

    unlv Repository record for A study of recognition coating response for quartz crystal microbalances (opens in a new tab) Download PDF for A study of recognition coating response for quartz crystal microbalances (opens in a new tab)

  2. Instrumental techniques for improving the measurements based on Quartz Crystal Microbalances (Técnicas instrumentales para mejorar las mediciones con microbalanzas de cuarzo)

    L'Electrogravimetria AC empra una microbalança de quars electroquímica (EQCM) en règim dinàmic. En l'EQCM un dels elèctrodes d'or depositats sobre el cristall és recobert amb una fina pelolícula d'un polímer electroactiv i és emprat com a elèctrode de treball (WE) dins d'una celola electroquímica. …

    upv Repository record for Instrumental techniques for improving the measurements based on Quartz Crystal Microbalances (Técnicas instrumentales para mejorar las mediciones con microbalanzas de cuarzo) (opens in a new tab)

  3. Condensation and sublimation of carbon dioxide and water molecules at cryogenic temperatures

    … made using a molecular beam and quartz crystal microbalances. The dependence of the condensation coefficient on variables such as population density on the substrate, temperature of the substrate, molecular beam intensity and temperature of the molecular beam, was investigated. The results are …

    must-thes Repository record for Condensation and sublimation of carbon dioxide and water molecules at cryogenic temperatures (opens in a new tab)

  4. Development of a Magnetically Enhanced Quartz Crystal Microbalance

    … devices, more specifically: quartz crystal microbalances (QCM). In an attempt to push the detection limit of these devices, a race to find novel methods for enhancing the resonator output has transpired. This study explores the feasibility and implementation of a technique in which the QCM …

    unr Repository record for Development of a Magnetically Enhanced Quartz Crystal Microbalance (opens in a new tab)

  5. Sorption of Benzene, Toluene and Ethylbenzene by Plasticized Poly (Ethyl Methacrylate) Using Quartz Crystal Microbalance at 298.15K

    Quartz crystal microbalances (QCM) are chemical sensors used for liquid and vapor sensing. In this thesis work, plasticized poly (ethyl methacrylate) (PEMA) coated QCM was used to study sorption behavior of benzene, ethylbenzene and toluene in respective polymer at 298.15K. Poly (ethyl …

    usf Repository record for Sorption of Benzene, Toluene and Ethylbenzene by Plasticized Poly (Ethyl Methacrylate) Using Quartz Crystal Microbalance at 298.15K (opens in a new tab)

  6. Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance

    Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest …

    usf Repository record for Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance (opens in a new tab)

  7. Arabinoglucuronoxylan and Arabinoxylan Adsorption onto Regenerated Cellulose Films

    … cellulose and hemicelluloses, and quartz crystal microbalances with dissipation monitoring (QCM-D), surface plasmon resonance (SPR) and atomic force microscopy (AFM) are widely used to investigate polymer adsorption/desorption at liquid/solid interfaces. In this study, smooth trimethylsilyl …

    vt Repository record for Arabinoglucuronoxylan and Arabinoxylan Adsorption onto Regenerated Cellulose Films (opens in a new tab)

  8. Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance

    … mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. Copolymers of …

    usf Repository record for Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance (opens in a new tab)

  9. Near Field Electrospinning of Nanofibers for Multi-Modal Hydrogen Sensing

    … quartz tuning forks (QTF) and quartz crystal microbalances (QCM). Near-field electrospinning is used to deposit uniform, semi-conductive nanofibers connecting the two prongs of a QTF. Electrospinning parameters are also optimized on QCM to maximize sensing performance. The most important …

    calgary Repository record for Near Field Electrospinning of Nanofibers for Multi-Modal Hydrogen Sensing (opens in a new tab)

  10. Effects of orientation and mobility of surface modifiers on the selectivity and efficiency of chemical interactions at selected chemically modified surfaces.

    … at a surface. Finally, quartz crystalline microbalances modified with physisorbed polymer layers have been studied by correspondence analysis. In this case, it has been shown that the polymer backbone of the modifying agent plays an important role in determining the selectivity of the …

    arizona-thes Repository record for Effects of orientation and mobility of surface modifiers on the selectivity and efficiency of chemical interactions at selected chemically modified surfaces. (opens in a new tab)

  11. Detection of Quercetin using Polymer Coated Quartz Crystal Microbalance and the Modification of á-Zirconium Phosphate to Develop a Sorbent for Organic Pollutant Removal

    … polymers to develop coatings for quartz crystal microbalances as well as layered zirconium phosphate for developing sorbents for organic pollutant removal. In Chapter 2, a brief summary of the analytical techniques used in this study, as well as preparation methods for the sorbents, is presented. …

    marquette Repository record for Detection of Quercetin using Polymer Coated Quartz Crystal Microbalance and the Modification of á-Zirconium Phosphate to Develop a Sorbent for Organic Pollutant Removal (opens in a new tab)

  12. Engineering Applications of Surface Plasmon Resonance: Protein–Protein and Protein–Molecule Interactions

    … resonance (SPR) devices and quartz crystal microbalances (QCM) are two real-time, label free methods that can be used to detect the interactions between molecules on surfaces. These devices often employ self-assembled monolayers (SAMs) to produce specific surfaces for studying …

    waterloo Repository record for Engineering Applications of Surface Plasmon Resonance: Protein–Protein and Protein–Molecule Interactions (opens in a new tab)

  13. Erosion, deposition and material migration in the JET divertor with carbon and ITER-like walls

    … varying the surfaces deposited on; quartz microbalances (QMBs) use piezoelectric crystals to measure changes in deposited mass. A simple, geometrical model is used to describe the rotating collector depositions over long timescales, incorporating experimental data from sources such as …

    whiterose Download PDF for Erosion, deposition and material migration in the JET divertor with carbon and ITER-like walls (opens in a new tab)

  14. Detection of Lysophosphatidic Acid in Serum; Towards a Cost Effective Test for Ovarian Cancer

    … mode biosensors, also known as quartz crystal microbalances, showed that the background fouling signal was too large for a test to be developed on this class of devices. Instead a test based on colorometric sensing of dye modified actin was conceived and evaluated. This test comprised of the …

    toronto-retro Repository record for Detection of Lysophosphatidic Acid in Serum; Towards a Cost Effective Test for Ovarian Cancer (opens in a new tab)

  15. Understanding adhesion to monitor and control environmental processes : from virus detection to membrane fouling mitigation

    Adhesion is a physicochemical process of great importance for various environmental engineering technologies including those that are employed in water treatment facilities. Understanding adhesion is the key to elucidating separation mechanisms in unit processes and operations such as flocculation, …

    msu Repository record for Understanding adhesion to monitor and control environmental processes : from virus detection to membrane fouling mitigation (opens in a new tab)

  16. Assessing the Adsorption of Various Proteins with Conformational Screening Utilizing k-Means Clustering and CHARMM Potential Energy Calculations

    Utilizing Quartz Crystal Microbalances (QCMB) to study the interaction of biochemical systems at interfaces is a diverse field with many potential applications. However, with an unfunctionalized surface, this technique suffers from a lack of known binding specificity which can denature the protein …

    clemson Repository record for Assessing the Adsorption of Various Proteins with Conformational Screening Utilizing k-Means Clustering and CHARMM Potential Energy Calculations (opens in a new tab)

  17. Magnetic quartz crystal microbalance

    In this thesis, a new technique for using quartz crystal microbalance (QCM) in magnetic field was explored. This technique would take advantage of the sensitive nature of QCM to vibration changes. The idea is to perturb the QCM vibrations with magnetic materials on it by applying magnetic field. A …

    gatech Repository record for Magnetic quartz crystal microbalance (opens in a new tab)

  18. Phase Behavior of Binary Ionic Liquid Systems: Ionic Liquids with Ammonia, Carbon dioxide, and Dihydroxy Alcohols

    … were conducted using gravimetric (IGA and XEMIS microbalances) and volumetric (high-pressure view cell) methods. In this study, the solubility of CO2 in pyrrolidinium ionic liquids increases with increasing pressure and decreasing temperature. However, the high-pressure behavior (above 10 MPa) …

    ku Repository record for Phase Behavior of Binary Ionic Liquid Systems: Ionic Liquids with Ammonia, Carbon dioxide, and Dihydroxy Alcohols (opens in a new tab)

  19. Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance

    This thesis uses surface sensitive tools to characterize the effect of a solid surface on immobilized biomacromolecules. This includes understanding how the surface can change the affinity of these macromolecules to small molecules compared to bulk studies. Two classes of immobilized …

    rice Repository record for Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance (opens in a new tab)

Page 1 of 2