Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Microbeams"”.

  1. Mechanical Behavior of Polycrystalline Copper Microbeams

    This study investigates the mechanical properties of polycrystalline copper micro-cantilevers. To accomplish this, the grain size of the polycrystalline copper samples was reduced using equal channel angular pressing (ECAP) so that the average grain size was comparable to the cantilever thickness. …

    buffalo Repository record for Mechanical Behavior of Polycrystalline Copper Microbeams (opens in a new tab)

  2. Thermomechanical behavior of single crystal silicon microbeams under bending at elevated temperatures

    Understanding the deformation mechanisms of materials at high temperature at the micro/nanoscale became important with the increasing miniaturization of electronic and mechanical devices. Silicon is the most commonly used material in these devices. Bulk silicon is brittle at room temperature, but …

    uiuc Repository record for Thermomechanical behavior of single crystal silicon microbeams under bending at elevated temperatures (opens in a new tab)

  3. Investigation of the effects of extreme stress gradients on fatigue behavior of nickel microbeams

    … properties of 20-μm-thick electroplated Ni microbeams in both mild (30°C, 50% RH) and harsh (80°C, 90% RH) environments. The technique relies on the measured evolution of the resonance frequency throughout the fatigue test and finite element models to calculate a fatigue life corresponding …

    gatech Repository record for Investigation of the effects of extreme stress gradients on fatigue behavior of nickel microbeams (opens in a new tab)

  4. Charge Collection Studies on Integrated Circuit Test Structures using Heavy-Ion Microbeams and MEDICI Simulation Calculations

    … structures were experimentally studied, using microbeams produced at Sandia National Laboratories. A new technique, Diffusion Time Resolved IBICC, is first proposed in this work to measure the average arrival time of the diffused charge, which can be related to the first moment (or the average …

    unt Repository record for Charge Collection Studies on Integrated Circuit Test Structures using Heavy-Ion Microbeams and MEDICI Simulation Calculations (opens in a new tab)

  5. Fatigue Mechanisms under the Low and High Cycle Fatigue Regimes in Nickel Microbeams under Extreme Stress Gradients

    … work investigates the fatigue behavior of Ni microbeams subjected to size effects (extreme stress/strain gradients and microstructurally small cracks) under fully reversed loadings. The microbeams are loaded under bending and subjected to in situ Scanning Electron Microscope (SEM) High and …

    gatech Repository record for Fatigue Mechanisms under the Low and High Cycle Fatigue Regimes in Nickel Microbeams under Extreme Stress Gradients (opens in a new tab)

  6. Investigation of the Mechanical Behavior of Microbeam-Based MEMS Devices

    An investigation into the responses of microbeams to electric actuations is presented. Attention is focused mainly on the use of microbeams in two important MEMS-based devices: capacitive microswitches and resonant microsensors. Nonlinear models are developed to simulate the behavior of the …

    vt Repository record for Investigation of the Mechanical Behavior of Microbeam-Based MEMS Devices (opens in a new tab)

  7. Characterization of plastic deformation mechanisms in ultrafine grained FCC metals using MEMS based nanomechanical testing methods

    … on very high cycle fatigue behavior of Ni microbeams under extreme stress gradients. FIB, SEM and EDS techniques were used to characterize cracking in the microbeams and models were developed to rationalize the observations. These studies have provided new insights towards our understanding …

    gatech Repository record for Characterization of plastic deformation mechanisms in ultrafine grained FCC metals using MEMS based nanomechanical testing methods (opens in a new tab)

  8. Samarium-Doped Fluorophosphate and Fluoroaluminate Glasses for High-Dose High-Resolution Dosimetry for Microbeam Radiation Therapy

    … fractionated, planar beams are referred to as microbeams, and have a thickness of 20 – 50 µm and are separated by distances of 100 – 400 µm. The dose delivered at the center of the microbeam can be on the order of thousands of Grays (Gy), whereas the dose between each microbeam should be kept …

    sask Repository record for Samarium-Doped Fluorophosphate and Fluoroaluminate Glasses for High-Dose High-Resolution Dosimetry for Microbeam Radiation Therapy (opens in a new tab)

  9. Radioaktyvių branduolių sluoksnių kūrimas grafito matricoje naudojant didelių energijų jonų pluoštelius /

    … in a graphite matrix using high-energy ion microbeams, specifically – creating a layer of 7Be in nuclear graphite using 7Li(p,n)7Be reaction. The theoretical evaluation was followed by an experiment – implanting 26 keV energy 7Li ions into one surface of the graphite sample and then …

    vilnius Repository record for Radioaktyvių branduolių sluoksnių kūrimas grafito matricoje naudojant didelių energijų jonų pluoštelius / (opens in a new tab)

  10. Modeling and Simulation of Microelectromechanical Systems in Multi-Physics Fields

    … and novel RF MEMS switches employing resonant microbeams. We first study microbeams excited near their fundamental natural frequencies (primary-resonance excitation). We investigate the dynamic pull-in instability and formulate safety criteria for the design of MEMS sensors and RF filters. We …

    vt Repository record for Modeling and Simulation of Microelectromechanical Systems in Multi-Physics Fields (opens in a new tab)

  11. Optical and thermal properties of samarium-doped fluorophosphate and fluoroaluminate glasses for high-dose, high-resolution dosimetry applications

    … to the tumor in the form of an array of planar microbeams. MRT dosimetry is an extremely challenging task and no current detector can provide the required wide dynamic rang and high spatial resolution. In this thesis, fluorophosphate (FP) and fluoroaluminate (FA) glass plates doped with …

    sask Repository record for Optical and thermal properties of samarium-doped fluorophosphate and fluoroaluminate glasses for high-dose, high-resolution dosimetry applications (opens in a new tab)

  12. CHARACTERISATION OF THE MECHANICAL BEHAVIOUR OF NETWORKS AND WOVEN FABRICS WITH A DISCRETE HOMOGENIZATION MODEL

    … The fibres in the network have been treated like microbeams, having both extensional and bending stiffness, with different types of connection, according to the pattern and detail of the network. The developed procedure was applied for obtaining the homogenized mechanical models for some types of …

    catania Repository record for CHARACTERISATION OF THE MECHANICAL BEHAVIOUR OF NETWORKS AND WOVEN FABRICS WITH A DISCRETE HOMOGENIZATION MODEL (opens in a new tab)

  13. Fabrication of Tissue Precursors Induced by Shape-changing Hydrogels

    … to correlate with the lateral swelling of the microbeams, which is induced by thermal activation, hydration and shape distortion of the patterns. The mechanism of cell detachment was primarily driven by strain, which occurred almost instantaneously above a critical strain of 25%. This …

    usf Repository record for Fabrication of Tissue Precursors Induced by Shape-changing Hydrogels (opens in a new tab)

  14. Μελέτη και ανάλυση μίκρο- και νανομετρολογικών διατάξεων

    … and computational calibration methods of Silicon microbeams, the interactions of Silicon and Carbon nanotips with semiconducting samples for topographic and nanoscratching applications and the vibrational and mechanical properties of composite Si/Ge nanobeams. Initially, we present results from …

    greece Repository record for Μελέτη και ανάλυση μίκρο- και νανομετρολογικών διατάξεων (opens in a new tab)

  15. Development of a Thin CVD Diamond Detector as a Transmission-Type Alpha Particle Counter at McMaster University Biological Microbeam Facility

    Microbeams have been applied in radiobiology research for decades. The goal is to irradiate single cellular and subcellular targets with individual charged particles. This study describes the simulation and fabrication of a super-thin single crystalline chemical vapor deposited diamond membrane, …

    mcmaster Repository record for Development of a Thin CVD Diamond Detector as a Transmission-Type Alpha Particle Counter at McMaster University Biological Microbeam Facility (opens in a new tab)

  16. DESIGN AND CONSTRUCTION OF A SILICON SCHOTTKY DIODE DETECTOR FOR SINGLE PROTON COUNTING AT THE MCMASTER MICROBEAM LABORATORY

    Microbeams have been used for radiation biology research since their introduction in the 1950s. A goal since their inception has been to irradiate individual cells and sub-cellular components with individual charged particles. These two criteria have been simultaneously achievable only within the …

    mcmaster Repository record for DESIGN AND CONSTRUCTION OF A SILICON SCHOTTKY DIODE DETECTOR FOR SINGLE PROTON COUNTING AT THE MCMASTER MICROBEAM LABORATORY (opens in a new tab)

  17. Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems

    … Further research on proton mini- and microbeams have been shown to have an increased therapeutic index when compared to traditional SFRT. Despite the body of research showing its biologic benefits compared to other more traditional methods of radiation therapy, proton minibeam …

    gatech Repository record for Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems (opens in a new tab)

  18. Radiobiological Response of Healthy and Tumour-Bearing Rat Brains To Synchrotron Microbeam Radiation

    … x-rays delivered as an array of parallel microbeams in high doses of irradiation in fractions of seconds. The aims of this study were to 1) investigate the induction of bystander effects after normal and tumour-bearing rat brains were exposed to MRT and homogenous radiation; 2) validate a …

    mcmaster Repository record for Radiobiological Response of Healthy and Tumour-Bearing Rat Brains To Synchrotron Microbeam Radiation (opens in a new tab)

  19. Structural instabilities for the design and control of computational materials and structures

    … work is that structural instabilities, in single microbeams and assembled structures, can be tailored to build in computational capabilities into structural systems, thus mimicking advanced circuitry functionalities using only mechanical loading in structural elements. In this thesis, we …

    msu Repository record for Structural instabilities for the design and control of computational materials and structures (opens in a new tab)

Page 1 of 2