Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"Microcantilever Sensor"”

  1. A model for simulating the flow of fluid through a microcantilever sensor cell

    Microcantilever sensors are highly sensitive detectors capable of detecting target chemicals in solutions with concentrations in the parts per billion. Commercial and custom built sensor-based instruments make use of one or more probes consisting of eight cantilevers each. Until now the cantilevers …

    newfoundland Repository record for A model for simulating the flow of fluid through a microcantilever sensor cell (opens in a new tab)

  2. Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance

    … protein (LacI), are characterized using microcantilever sensors and quartz crystal microbalance with dissipation (QCM-D). The first part of this thesis reports the use of microcantilever beams, an ultrasensitive sensor for measuring the surface free energy changes on a substrate induced …

    rice Repository record for Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance (opens in a new tab)

  3. Semiempirical modified embedded atom potentials for silicon, silver and gold systems

    … of these potentials for the specific case of microcantilever sensor fabrication and characterization have been outlined, including interfacial stress and surface analyses.

    newfoundland Repository record for Semiempirical modified embedded atom potentials for silicon, silver and gold systems (opens in a new tab)

  4. A CMOS wideband amplifier for use in a microcantilever sensing device

    … open-loop amplifier for potential use in a microcantilever sensor platform were designed, fabricated and evaluated in two different processes, the AMI0.8 um and AMI 1.2 um 5 V CMOS processes. Bench performance testing of the amplifiers was performed and compared to simulation results. The …

    ut-knoxville Repository record for A CMOS wideband amplifier for use in a microcantilever sensing device (opens in a new tab)

  5. Simulation of the Molecular Interactions for the Microcantilever Sensors

    Microcantilever sensor has gained much popularity because of its high sensitivity and selectivity. It consists of a micro-sized cantilever that is usually coated on one side with chemical/biological probe agents to generate strong attraction to target molecules. The interactions between the probe …

    alberta Repository record for Simulation of the Molecular Interactions for the Microcantilever Sensors (opens in a new tab)

  6. Towards detecting the human immunodeficiency virus (HIV-1) using microcantilever sensors

    … weeks (sometimes months) after an infection. Microcantilever sensors were used in this work to detect the hybridization process. The active microcantilever was functionalized with thiol modified single stranded DNA with the sequence (5’-/ThioMC6-D/ TCT GTA TGT CAT TGE CAG TCC AGC T-3)’. The …

    newfoundland Repository record for Towards detecting the human immunodeficiency virus (HIV-1) using microcantilever sensors (opens in a new tab)

  7. Development of microcantilever biosensing platforms

    Microcantilever sensor system as a promising field attracted much attention recently. This system has the potential to be applied for a biosensing technology which is parallel reference, label free, sensitive and real time. In this thesis, polyimide has been selected as a material to fabricate …

    heriot-watt Repository record for Development of microcantilever biosensing platforms (opens in a new tab)

  8. Characterization & Application of Immobilized Biomacromolecules using Microcantilever and QCM Sensors

    … of this thesis is to develop surface-based biosensors for the characterization and application of biomacromolecules at the liquid-solid interface. In this study, two analytical surface-sensitive sensors are utilized: microcantilevers and quartz crystal microbalance with dissipation (QCM-D). …

    rice Repository record for Characterization & Application of Immobilized Biomacromolecules using Microcantilever and QCM Sensors (opens in a new tab)

  9. Fabrication and investigation of nano-channeled anodized aluminum oxide (AAO) microcantilever gas/vapour sensors with enhanced sensitivity and modified selectivity

    Microcantilevers as one of the most fundamental forms of MEMS devices have found extensive applications in various fields including sensors during the last decade. Simple mechanism, high throughput fabrication, direct and fast conversion of chemical/ biological stimulus to mechanical response in …

    calgary Repository record for Fabrication and investigation of nano-channeled anodized aluminum oxide (AAO) microcantilever gas/vapour sensors with enhanced sensitivity and modified selectivity (opens in a new tab)

  10. Chemical Mixture Discrimination and Quantification Analysis Using Photothermal Cantilever Detection Spectroscopy and Machine Learning

    … and the food industry. A combination of sensor arrays and pattern recognition analysis forms the basis for the 'electronic nose sensing' approach. A recent variation of the electronic nose approach uses photothermal cantilever deflection spectroscopy (PCDS). In PCDS, a bi-material …

    buffalo Repository record for Chemical Mixture Discrimination and Quantification Analysis Using Photothermal Cantilever Detection Spectroscopy and Machine Learning (opens in a new tab)

  11. In-Plane, All-Photonic Transduction Method for Silicon Photonic Microcantilever Array Sensors

    … all-photonic transduction method for photonic microcantilever arrays that is scalable to large arrays for sensing applications in both bio- and nanotechnology. Our photonic transduction method utilizes a microcantilever forming a single mode rib waveguide and a differential splitter consisting …

    byu Repository record for In-Plane, All-Photonic Transduction Method for Silicon Photonic Microcantilever Array Sensors (opens in a new tab)

  12. Development of microcantilever sensors for cell studies

    … and nano- electromechanical devices such as microcantilevers have paved the way for a large variety of new possibilities, such as the rapid diagnosis of diseases and a high throughput platform for drug discovery. Conventional cell assay methods rely on the addition of reagents, disrupting the …

    heriot-watt Repository record for Development of microcantilever sensors for cell studies (opens in a new tab)

  13. Analytical Modeling of Polymer-Coated Microcantilever Dynamic Microsensors

    … years. With the increasing demand of micro sensors in the fields of biowarfare and medicine, there is a need for the investigation of miniaturized, effective and highly sensitive devices for the detection of gaseous and aqueous contaminants/antibodies. Recent advancements in MEMS fabrication …

    marquette Repository record for Analytical Modeling of Polymer-Coated Microcantilever Dynamic Microsensors (opens in a new tab)

  14. Linear, nonlinear and networked-based vibration control of smart flexible structures

    … structures • Consensus-based multi-piezoelectric microcantilever sensor • Leader-follower based consensus vibration controller • Consensus Positive Position Feedback The mentioned approaches which are designed for sensing and control of smart flexible structures are numerically and/or …

    alabama Repository record for Linear, nonlinear and networked-based vibration control of smart flexible structures (opens in a new tab)

  15. “Enhancement of Sensitivity and Selectivity of Chemical Sensors Through Thin Film Coatings and Surface Modifications

    <p>Chemical sensors have become major analytical tools for how we monitor<br />and obtain information about the chemical nature of ourselves and our<br />surroundings. Two characteristics of chemical sensors that are under constant<br />development and improvement are their selectivity and their …

    utk-theses Repository record for “Enhancement of Sensitivity and Selectivity of Chemical Sensors Through Thin Film Coatings and Surface Modifications (opens in a new tab)

  16. Development of calix[4]arene-functionalized microcantilever array sensing system for the rapid, sensitive and simultaneous detection of metal ions in aqueous solutions

    … capabilities of calix[4]arene-functionalized microcantilevers towards specific metal ions and 2) developing a new16-microcantilever array sensing system for the rapid, and simultaneous detection of metal ions in fresh water. Part I of this thesis reports on the use of three new bimodal …

    newfoundland Repository record for Development of calix[4]arene-functionalized microcantilever array sensing system for the rapid, sensitive and simultaneous detection of metal ions in aqueous solutions (opens in a new tab)

  17. Silicon Piezoresistive Microcantilever For Potentiometric Sensing

    … research focus on miniaturization of chemical sensors due to their applications in various fields, e.g., environmental monitoring, medical diagnosis, and national security. In general, a miniaturized chemical sensor inevitably depends on functionalization layers, which alter their electrical …

    south-carolina Repository record for Silicon Piezoresistive Microcantilever For Potentiometric Sensing (opens in a new tab)

  18. INFERRING MECHANICAL RESONANCES IN MICRO - AND NANOCANTILEVERS USING THE HARMONIC DETECTION OF RESONANCE (HDR) METHOD TO DEVELOP A NOVEL SENSING PLATFORM

    … to develop sensing platforms based on smart microcantilevers. A microcantilever beam is one of the simplest MEMS structures which forms the basis for portable, fast and highly sensitive schemes that are capable of measuring small deflections in static or dynamic response due to changes in …

    clemson Repository record for INFERRING MECHANICAL RESONANCES IN MICRO - AND NANOCANTILEVERS USING THE HARMONIC DETECTION OF RESONANCE (HDR) METHOD TO DEVELOP A NOVEL SENSING PLATFORM (opens in a new tab)

  19. Microfluidic Devices and Biosensors

    … important aspects of microfluidic devices and biosensors. Specifically, this dissertation reports: (1) a new and effective room temperature method of bonding polydimethylsiloxane (PDMS) microfluidics to substrates such as silicon and glass, (2) a new microfluidic pump concept and implementation …

    byu Repository record for Microfluidic Devices and Biosensors (opens in a new tab)

  20. Lateral-Mode Vibration of Microcantilever-Based Sensors in Viscous Fluids Using Timoshenko Beam Theory

    Dynamic-mode microcantilever-based devices are well suited to biological and chemical sensing applications. However, these applications often necessitate liquid-phase sensing, introducing significant fluid-induced dissipative forces and reducing device quality factors (Q). Recent experimental and …

    marquette Repository record for Lateral-Mode Vibration of Microcantilever-Based Sensors in Viscous Fluids Using Timoshenko Beam Theory (opens in a new tab)

Page 1 of 2