Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"Microchannel Plate Detector"”.
-
Extreme Ultraviolet Polarimetry with Laser-Generated High-Order Harmonics
… positioning system that places harmonics on the microchannel plate detector with an accuracy of 0.3 mm, which allows a spectral resolution of about 180. We have demonstrated that reflectance as low as 0.2% can be measured at EUV wavelengths and that this data is repeatable to within the error of …
-
Study of Electron-Impact Induced Fragmentation of Thymine
… time-of-flight mass spectrometer with a microchannel plate detector is used to detect and mass resolve the positively charged fragments. LabVIEW based data acquisition techniques are used to accumulate the time-of-flight data as a function of electron impact energy. The work described in …
-
Construction and calibration of a custom time-of-flight mass spectrometer and its use in measuring the reaction kinetics of transition metal ion-organic interactions.
… The revelatory hardware for our instrument is a microchannel plate detector (MCP). The MCP is mounted on the exit of a custom designed and built hemispherical energy analyzer (sector), which acts as an energy filter. This filtering characteristic of the sector permits study of selected ionized …
-
Resonance Enhanced Multiphoton Ionization Studies of Dichlorotoluenses, Dichloroanilines, and Dichlorophenols
… process and the sensitivity of a TOF-MF with a microchannel plate detector. A pulsed valve inlet system was tested to determine its effectiveness in “cooling” molecules but it was not used for the bulk of the studies performed. The instrument was tested using molecular and atomic bromine, atomic …
-
Low-Energy Electron Impact Fragmentations of the Polycyclic Aromatic Hydrocarbon Anthracene
… time-of-flight mass spectrometer with a microchannel plate detector is used to mass-resolve and detect the fragment ions. A multichannel scaler card is used for acquiring single mass spectra. Data acquisition is controlled by LabVIEW code, which ramps the electron impact energy from 0 to …
-
Development of an Apparatus for the Study of Electron Impact Fragmentation of Molecular Clusters
… time-of-flight mass spectrometer with a microchannel plate detector. Neutral metastable fragments are detected using a channeltron with appropriately biased meshes in front to avoid the detection of charged particles. For both types of fragment data acquisition takes place using a …
-
Enabling Validation of a CubeSat Compatible Wind Sensor
The Ram Energy Distribution Detector (REDD) is a new CubeSat-compatible space science instrument that measures neutral wind characteristics in the upper atmosphere. Neutral gas interactions with plasma in the ionosphere/thermosphere are responsible for spacecraft drag, radio frequency disturbances …
-
Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
… mass range. However, due to its dependence on microchannel plate (MCP) detectors and high acceleration voltages, this technique has rarely been applied in the MLT. A new TOF-MS for making composition measurements of both charged and neutral particles in the upper atmosphere has been developed …