Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Micromechanical Testing"”.

  1. Micromechanical testing of oxidized grain boundaries

    … for lifting-out whole cantilevers after testing and for performing 3D focussed ion beam sequencing (3D FIB-SEM) while preserving a thin central region of the cantilever for further TEM sample preparation was developed and is presented.</p> <p>In lieu with recent efforts of the main …

    oxford Repository record for Micromechanical testing of oxidized grain boundaries (opens in a new tab)

  2. Micromechanical testing of irradiated tungsten for fusion

    … of strain rate (SR) and radiation damage through micromechanical testing of [001]-orientated unirradiated single crystal W and single crystal W irradiated to 1.67 dpa at 900 °C.</p> <p>Constant strain rate spherical nanoindentation experiments using 5 μm and 10 μm radius tips were executed at …

    oxford Repository record for Micromechanical testing of irradiated tungsten for fusion (opens in a new tab)

  3. Development of a micromechanical testing method for single wood fibres

    Natural fibre-based materials are widely used in everyday life in the form of pa-per, paperboard, films, textiles and biocomposites. Environmental awareness andthe growing concern regarding the large energy consumption coupled to the pro-duction of traditional synthetic fibres have prompted several …

    chalmers Repository record for Development of a micromechanical testing method for single wood fibres (opens in a new tab)

  4. Micromechanical testing for the evaluation of chemo-mechanical alteration of CO₂ storage rocks

    … two weeks. I designed and constructed a scratch testing apparatus to conduct scratches on the laboratory altered rock samples. Scratch toughness and hardness show decreases of up to 60% in the case of Entrada sandstone and 92% in the case of Summerville siltstone after CO2-induced alteration in …

    texas Repository record for Micromechanical testing for the evaluation of chemo-mechanical alteration of CO₂ storage rocks (opens in a new tab)

  5. INVESTIGATING THE FATIGUE BEHAVIOR OF INCONEL 939 AND INCONEL 718 THROUGH MICROMECHANICAL TESTING

    A detailed evaluation of fatigue crack growth (FCG) in a silicon-modified Inconel 939 alloy, fabricated via laser powder bed fusion additive manufacturing (L-PBF AM), was performed using cyclic bending tests on pre-notched microscale cantilevers with a cross-sectional dimension of 25 µm × 25 µm. To …

    lsu-thes Repository record for INVESTIGATING THE FATIGUE BEHAVIOR OF INCONEL 939 AND INCONEL 718 THROUGH MICROMECHANICAL TESTING (opens in a new tab)

  6. Micromechanical Testing of Pristine and Delithiated Single Carbon Fibres for Structural Battery Composite

    Reduction of mass of the battery system in electric vehicles (EV) is one of the major requirements of the use of EV in place of internal combustion (IC) engines. A novel solution to reduce the mass of the system is by replacing the present battery material with multifunctional material. These are …

    chalmers Repository record for Micromechanical Testing of Pristine and Delithiated Single Carbon Fibres for Structural Battery Composite (opens in a new tab)

  7. Experimental Investigation of Micro and Macro Mechanics of Carbon Fiber Composites and Their Relationship

    … conventional tensile, compressive and shear testing of specimens as per relevant standards, whereas the micromechanics part involves indentation of fibers and matrix to estimate the bonding strength of the fiber/matrix, which is a very important parameter for the behavior of composite, and …

    sdstate Repository record for Experimental Investigation of Micro and Macro Mechanics of Carbon Fiber Composites and Their Relationship (opens in a new tab)

  8. High resolution characterisation of H on stress corrosion cracking in nuclear materials

    … in SCC. Localised and high-resolution testing has been employed successfully to characterise key processes in SCC crack propagation. For this reason, nanoindenta- tion, transmission Kikuchi diffraction (TKD), NanoSIMS and Thermal desorption spectrscopy (TDS) have been used to …

    oxford Repository record for High resolution characterisation of H on stress corrosion cracking in nuclear materials (opens in a new tab)

  9. Particle Friction, Breakage, and Damage: Deformation Mechanisms of Brittle Granular Materials

    … a granular material was examined using a new micromechanical testing apparatus to study smooth and rough soda lime glass particles in carefully controlled dry, humid, and lubricated environments during normal compression and shearing. The breakage of granular particles was studied across …

    jhu Repository record for Particle Friction, Breakage, and Damage: Deformation Mechanisms of Brittle Granular Materials (opens in a new tab)

  10. Radiation Response, Mechanical Property Changes, and Corrosion Behavior of Molten Salt Reactor Materials

    … N was exposed to light ion irradiation, micromechanical testing, and immersion corrosion using FLiNaK molten salt after either irradiation or static strain mounting using the three-point bending technique. 316SS, either coated using a modified cathodic cage plasma nitriding technique or …

    tamu Repository record for Radiation Response, Mechanical Property Changes, and Corrosion Behavior of Molten Salt Reactor Materials (opens in a new tab)

  11. Investigating Fuel Cladding Coating Materials for Accident Tolerant Fuels

    … via cold spraying. This study utilized various testing methods, including accelerator irradiation, SEM imaging, TEM imaging, micropillar compression, nanoindentation, and cantilever bending. The research performed is necessary for confirming phase diagram predictions, creating kinetic data to …

    tamu Repository record for Investigating Fuel Cladding Coating Materials for Accident Tolerant Fuels (opens in a new tab)

  12. Investigation of key challenges facing aerogel composites development through multiscale approach

    … composite mechanical response. Additionally, micromechanical testing of the interface between aerogel and fibre reinforcement has been performed for the first time to understand their bonding ability. By designing a method to deposit an aerogel droplet surrounding the fibre, the microbond …

    strathclyde Repository record for Investigation of key challenges facing aerogel composites development through multiscale approach (opens in a new tab)

  13. Microscale evaluation of epoxy matrix composites containing thermoplastic healing agent

    … (3) study the potential for self-healing through micromechanical testing. The effect of a 10 wt.% EMAA modified epoxy was investigated through infrared spectroscopy and differential scanning calorimetry (DSC) experiments. The results suggested that EMAA addition may cause changes during the epoxy …

    brazil-ufrn Repository record for Microscale evaluation of epoxy matrix composites containing thermoplastic healing agent (opens in a new tab)

  14. Characterizing Structure, Properties, and Deformation in Metallic Glasses and Olivine Using Instrumented Nanoindentation

    Micro- and nanomechanical testing can provide significant insight about the structure, properties, and behavior of materials. These techniques are nondestructive, require only limited amounts of material, and have been known to detect a brittle-to-ductile transition in mechanical behavior due to a …

    wustl Repository record for Characterizing Structure, Properties, and Deformation in Metallic Glasses and Olivine Using Instrumented Nanoindentation (opens in a new tab)

  15. REAL-TIME MONITORING OF DISLOCATION AVALANCHES IN METALS: AN INTEGRATED IN SITU MICROCOMPRESSION AND ACOUSTIC EMISSION STUDY

    … the integration of in situ microcompression testing and acoustic emission (AE) techniques. The primary objective was to develop a deeper understanding of the underlying dynamics of dislocation motion by studying strain burst behavior. This novel approach allowed for capturing a wider spectrum …

    jhu Repository record for REAL-TIME MONITORING OF DISLOCATION AVALANCHES IN METALS: AN INTEGRATED IN SITU MICROCOMPRESSION AND ACOUSTIC EMISSION STUDY (opens in a new tab)

  16. An exploration of the link between vertebral endplate fracture, velocity, and health of the intervertebral disc.

    … of relatively few participants. In-vitro tissue testing has demonstrated that pressurization of the intervertebral disc’s nucleus pulposus significantly contributes to the generation of growth plate fractures. However, a comprehensive biomechanical investigation of the mechanical consequences for …

    wilfrid-laurier Repository record for An exploration of the link between vertebral endplate fracture, velocity, and health of the intervertebral disc. (opens in a new tab) Download PDF for An exploration of the link between vertebral endplate fracture, velocity, and health of the intervertebral disc. (opens in a new tab)

  17. On the relationship between microstructure mechanical properties and weld metal hydrogen assisted cold cracking

    … advanced characterisation and micro-mechanical testing techniques to evaluate the fundamental link between microstructure, mechanical properties and HACC susceptibility for individual weld metal microstructural constituents. This first part of the work examined the microstructure and mechanical …

    adelaide Repository record for On the relationship between microstructure mechanical properties and weld metal hydrogen assisted cold cracking (opens in a new tab)

  18. Mechanical and Histological Characterization of Porcine Aortic Valves under Normal and Hypercholesterolemic Conditions

    Calcific aortic valve disease (CAVD) is associated with significant cardiovascular morbidity. While late-stage valve disease is well-described, there remains an unmet scientific need to elucidate early pathobiological processes. In CAVD, pathological differentiation of valvular interstitial cells …

    toronto-retro Repository record for Mechanical and Histological Characterization of Porcine Aortic Valves under Normal and Hypercholesterolemic Conditions (opens in a new tab)

Page 1 of 2